Comparison of stereotactic plans for brain tumors with two different multileaf collimating systems

被引:4
|
作者
Marrazzo, Livia [1 ]
Zani, Margherita [2 ]
Pallotta, Stefania [1 ,2 ]
Greto, Daniela [3 ]
Scoccianti, Silvia [3 ]
Talamonti, Cinzia [1 ,2 ]
Biti, Giampaolo [2 ,3 ]
Bucciolini, Marta [1 ,2 ]
机构
[1] Careggi Univ Hosp, Med Phys Unit, I-50134 Florence, Italy
[2] Univ Florence, Dept Biomed Expt & Clin Sci, Florence, Italy
[3] Careggi Univ Hosp, Radiotherapy Unit, I-50134 Florence, Italy
来源
关键词
central nervous system tumors; stereotactic radiosurgery; multileaf collimators; conformity index; homogeneity index; GUIDED CONFORMAL RADIOTHERAPY; LEAF COLLIMATOR; RADIOSURGERY; IMPACT; WIDTH;
D O I
10.1120/jacmp.v15i1.4100
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Linac-based stereotactic radiosurgery (SRS) has been widely used for treating small intracranial lesions. This technique allows conforming the dose distribution to the planning target volume (PTV), providing a steep dose gradient with the surrounding normal tissues. This is realized through dedicated collimation systems. The present study aims to compare SRS plans with two collimating systems: the beam modulator (BM) of the Elekta Synergy linac and the DirexGroup micromultileaf collimator (mu MLC). Seventeen patients (25 PTVs) were planned both with BM and mu MLC (mounted on an Elekta Precise linac) using the Odyssey (PerMedics) treatment planning system (TPS). Plans were compared in terms of dose-volume histograms (DVH), minimum dose to the PTV, conformity index (CI), and homogeneity index (HI), as defined by the TPS, and doses to relevant organs at risk (OAR). The mean difference between the mu MLC and the BM plans in minimum PTV dose was 5.7% +/- 4.2% in favor of the mu MLC plans. No statistically significant difference was found between the distributions of the CI values for the two planning modalities (p = 0.54), while the difference between the distributions of the HI values was statistically significant (p = 0.018). For both BM and mu MLC plans, no differences were observed in CI and HI, depending on lesion size and shape. The PTV homogeneity achieved by BM plans was 15.1% +/- 6.8% compared to 10.4% +/- 6.6% with mu MLC. Higher maximum and mean doses to OAR were observed in the BM plans; however, for both plans, dose constraints were respected. The comparison between the two collimating systems showed no substantial differences in terms of PTV coverage or OAR sparing. The improvements obtained by using mu MLC are relatively small, and both systems turned out to be adequate for SRS treatments.
引用
收藏
页码:27 / 37
页数:11
相关论文
共 50 条
  • [41] A Statistical Comparison of Prognostic Index Systems for Brain Metastases after Stereotactic Radiosurgery or Fractionated Stereotactic Radiation Therapy
    Rodrigues, G.
    Gonzalez-Maldonado, S.
    Bauman, G.
    Senan, S.
    Lagerwaard, E.
    CLINICAL ONCOLOGY, 2013, 25 (04) : 227 - 235
  • [42] Treatment Planning Comparison Study On. Two Different Multileaf Collimators Delivered with Volumetric Modulated Arc Therapy
    Zhang, R.
    Xiaomei, F.
    Bai, W.
    Zhang, X.
    Gao, Y.
    MEDICAL PHYSICS, 2015, 42 (06) : 3513 - 3513
  • [43] A Sequential Comparison on the Risk of Haemorrhage with Different Sizes of Biopsy Needles for Stereotactic Brain Biopsy
    Yuen, Jason
    Zhu, Cannon X. L.
    Chan, Danny T. M.
    Ng, Rebecca Y. T.
    Nia, Wai
    Poon, Wai Sang
    Ng, Ho Keung
    Mok, Vincent C. T.
    Wong, Laurence K. S.
    Cheung, Tom C. Y.
    Siu, Deyond Y. W.
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2014, 92 (03) : 160 - 169
  • [44] Comparison of different planning scenarios in stereotactic radiosurgery for irradiation of multiple brain metastases with an isocenter
    Ohlmann, Carsten
    Altergot, Angelika
    Palm, Jan
    Nuesken, Frank
    Hecht, Markus
    Dzierma, Yvonne
    STRAHLENTHERAPIE UND ONKOLOGIE, 2023, 199 : S123 - S123
  • [45] COMPARISON OF DIFFERENT IMAGING GEOMETRIES OF BRAIN SPECT SYSTEMS
    LIU, JG
    CHANG, W
    LONCARIC, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1995, 42 (04) : 1147 - 1153
  • [46] Dose analysis of InCise 2 multi leaf collimator and IRIS-based stereotactic radiotherapy plans for brain and liver tumors
    Ermis, Ekin
    Blatti-Moreno, Marcela
    Leiser, Dominic
    Cihoric, Nikola
    Schmidhalter, Daniel
    Henzen, Dominik
    Malthaner, Marco
    Hemmatazad, Hossein
    Tsikkinis, Alexandros
    Sermaxhaj, Burim
    Aebersold, Daniel M.
    Herrmann, Evelyn
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2019, 5 (03):
  • [47] Linear Energy Transfer Comparison Between IMPT Brain Plans Produced for Different Beamlines
    Sievert, D.
    Zhao, T.
    Zhang, T.
    Perkins, S.
    Badiyan, S.
    Traneus, E.
    Mazur, T.
    MEDICAL PHYSICS, 2022, 49 (06) : E328 - E329
  • [48] Survival of Patients with Primary Brain Tumors: Comparison of Two Statistical Approaches
    Selingerova, Iveta
    Dolezelova, Hana
    Horova, Ivanka
    Katina, Stanislav
    Zelinka, Jiri
    PLOS ONE, 2016, 11 (02):
  • [49] Comparison of intensity modulated radiation treatment plans developed by two commercial systems
    Dogan, N
    King, S
    Leybovich, LB
    Sethi, A
    Emami, B
    RADIOLOGY, 2002, 225 : 178 - 179
  • [50] Stereotactic radiosurgery for brain metastases: Comparison of lung carcinoma vs. non-lung tumors
    Williams, J
    Enger, C
    Wharam, M
    Tsai, D
    Brem, H
    JOURNAL OF NEURO-ONCOLOGY, 1998, 37 (01) : 79 - 85