Development of a univariate calibration model for pharmaceutical analysis based on NIR spectra

被引:27
|
作者
Blanco, M. [1 ]
Cruz, J. [1 ]
Bautista, M. [1 ]
机构
[1] Univ Autonoma Barcelona, Dept Quim, Unitat Quim Analit, E-08193 Barcelona, Spain
关键词
NIR spectroscopy; API determination; Correlation coefficients; PLS calibration;
D O I
10.1007/s00216-008-2426-9
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Near-infrared spectroscopy (NIRS) has been widely used in the pharmaceutical field because of its ability to provide quality information about drugs in near-real time. In practice, however, the NIRS technique requires construction of multivariate models in order to correct collinearity and the typically poor selectivity of NIR spectra. In this work, a new methodology for constructing simple NIR calibration models has been developed, based on the spectrum for the target analyte (usually the active principle ingredient, API), which is compared with that of the sample in order to calculate a correlation coefficient. To this end, calibration samples are prepared spanning an adequate concentration range for the API and their spectra are recorded. The model thus obtained by relating the correlation coefficient to the sample concentration is subjected to least-squares regression. The API concentration in validation samples is predicted by interpolating their correlation coefficients in the straight calibration line previously obtained. The proposed method affords quantitation of API in pharmaceuticals undergoing physical changes during their production process (e.g. granulates, and coated and non-coated tablets). The results obtained with the proposed methodology, based on correlation coefficients, were compared with the predictions of PLSI calibration models, with which a different model is required for each type of sample. Error values lower than 1-2% were obtained in the analysis of three types of sample using the same model; these errors are similar to those obtained by applying three PLS models for granules, and non-coated and coated samples. Based on the outcome, our methodology is a straightforward choice for constructing calibration models affording expeditious prediction of new samples with varying physical properties. This makes it an effective alternative to multivariate calibration, which requires use of a different model for each type of sample, depending on its physical presentation.
引用
收藏
页码:1367 / 1372
页数:6
相关论文
共 50 条
  • [41] Improvement of the piecewise direct standardisation procedure for the transfer of NIR spectra for multivariate calibration
    Bouveresse, E
    Massart, DL
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1996, 32 (02) : 201 - 213
  • [42] Application of Wavelet Packet Analysis in Estimating Soil Parameters Based on NIR Spectra
    Zheng Li-hua
    Li Min-zan
    Pan Luan
    Sun Jian-ying
    Tang Ning
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2009, 29 (06) : 1549 - 1552
  • [43] Pseudo-univariate calibration based on independent component analysis for determination of the carbendazim concentration in orange juice
    Ribeiro, Gessica M.
    Madivadua, Daniel A.
    Curti, Suzana M. M.
    Pantean, Leonardo P.
    Marco, Paulo Henrique
    Valderrama, Patricia
    MICROCHEMICAL JOURNAL, 2017, 134 : 114 - 118
  • [44] NIR analysis for batch process of ethanol precipitation coupled with a new calibration model updating strategy
    Xu, Bing
    Wu, Zhisheng
    Lin, Zhaozhou
    Sui, Chenglin
    Shi, Xinyuan
    Qiao, Yanjiang
    Analytica Chimica Acta, 2012, 720 : 22 - 28
  • [45] Development of an in-vivo PLS calibration model for the noninvasive measurement of blood hematocrit using NIR spectroscopy
    Soller, BR
    Zhang, SB
    Perras, K
    Gaca, C
    Rohrer, MJ
    Cutler, BS
    Salm, TJV
    Kaur, S
    Heard, SO
    BIOMEDICAL TOPICAL MEETINGS, TECHNICAL DIGEST, 2000, 38 : 220 - 222
  • [46] NIR analysis for batch process of ethanol precipitation coupled with a new calibration model updating strategy
    Xu, Bing
    Wu, Zhisheng
    Lin, Zhaozhou
    Sui, Chenglin
    Shi, Xinyuan
    Qiao, Yanjiang
    ANALYTICA CHIMICA ACTA, 2012, 720 : 22 - 28
  • [47] Assessment of internal quality attributes of mandarin fruit. 1. NIR calibration model development
    Guthrie, JA
    Walsh, KB
    Reid, DJ
    Liebenberg, CJ
    AUSTRALIAN JOURNAL OF AGRICULTURAL RESEARCH, 2005, 56 (04): : 405 - 416
  • [48] Multivariate calibration: A powerful tool in pharmaceutical analysis
    Damiani, Patricia C.
    Escandar, Graciela M.
    Olivieri, Alejandro C.
    Goicoechea, Hector C.
    CURRENT PHARMACEUTICAL ANALYSIS, 2005, 1 (02) : 145 - 154
  • [49] AN EFFICIENT APPROXIMATE ANALYSIS METHOD BASED ON AN EXACT UNIVARIATE MODEL FOR THE ELEMENT LOADS
    FUCHS, MB
    STEINBERG, Y
    STRUCTURAL OPTIMIZATION, 1991, 3 (02): : 107 - 114
  • [50] OPLC combined with NIR spectroscopy -: a novel technique for pharmaceutical analysis
    David, Adam Zoltan
    Mincsovics, Emil
    Antal, Istvan
    Furdyga, Eva
    Zsigmond, Zsolt
    Klebovich, Imre
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2006, 19 (111) : 355 - 360