Current THD Reduction and Anti-islanding Detection in Distributed Generation with Grid Voltage Distortion

被引:0
|
作者
Mok, Hyung Soo [1 ]
Choe, Gyu Ha [1 ]
Kim, Sang Hoon [2 ]
Lee, Jeong Min [3 ]
Suh, In Young [3 ]
机构
[1] Konkuk Univ, Dept Elect Engn, Hwayang 1 Dong, Seoul 143701, South Korea
[2] Kangwon Natl Univ, Dept Elect & Elect Engn, Kangwondo 200701, South Korea
[3] HYOSUNG CORP, Anyang, Gyeonggi Do, South Korea
关键词
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Phase angle in grid-connected inverter for DPGS(Distributed Power Generation Systems) is important information for current control. When different loads are connected to PCC(Point of Common Coupling) of grid, distorted grid voltage is taken place by load utility generating distorted current. Especially, in case the grid voltage is distorted by low order frequency such as 3(rd), 5(th) harmonic, phase angle of PLL(Phase Locked Loop) output is distorted. This paper analyze problem of current THD(Total Harmonic Distortion) due to distorted phase angle by distorted grid voltage, and propose control method compensating this problem. Also proposed anti-islanding detection method using distorted grid voltage is proposed in this paper. These proposed methods are verified by simulation and experiment.
引用
收藏
页码:989 / +
页数:2
相关论文
共 50 条
  • [41] Anti-islanding Protection for Distributed Generation Systems Based on Reactive Power Drift
    Jin, Yiding
    Song, Qiang
    Liu, Wenhua
    IECON: 2009 35TH ANNUAL CONFERENCE OF IEEE INDUSTRIAL ELECTRONICS, VOLS 1-6, 2009, : 3769 - +
  • [42] Wireless Networks for Voltage Stability Analysis and Anti-islanding Protection of Smart Grid System
    Sunny Katyara
    Ashfaque Hashmani
    Bhawani Shankar Chowdhary
    Hyder Abbas Musavi
    Anwar Aleem
    Faheem Akhtar Chachar
    Madad Ali Shah
    Wireless Personal Communications, 2021, 116 : 1361 - 1378
  • [43] Implementation of Anti-islanding Scheme for a Grid Connected Inverter
    Saikia, Arup Kumar
    Kapil, P. N.
    POWER ELECTRONICS AND RENEWABLE ENERGY SYSTEMS, 2015, 326 : 213 - 223
  • [44] New Low-Distortion Q-f Droop Plus Correlation Anti-Islanding Detection Method for Power Converters in Distributed Generation Systems
    Munoz-Cruzado-Alba, Jesus
    Villegas-Nunez, Javier
    Alberto Vite-Frias, Jose
    Manuel Carrasco-Solis, Juan
    Galvan-Diez, Eduardo
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2015, 62 (08) : 5072 - 5081
  • [45] Modified Sandia voltage shift anti-islanding scheme for distributed power generator systems
    Vazquez, Erick
    Vazquez, Nimrod
    Femat, Ricardo
    IET POWER ELECTRONICS, 2020, 13 (18) : 4226 - 4234
  • [46] Research of The Influence of Initiative Anti-Islanding Protection in High Penetration Rating of Distributed Generation
    Tang, Zongyao
    Zhang, Junfang
    2012 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2012,
  • [47] Intelligent Anti-Islanding Protection Scheme for Distributed Generations
    Kar, Susmita
    Samantaray, S. R.
    2013 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2013,
  • [48] An anti-islanding method for single-phase inverters based on a grid voltage sensorless control
    Liserre, Marco
    Pigazo, Alberto
    Dell'Aquila, Antonio
    Moreno, Victor M.
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2006, 53 (05) : 1418 - 1426
  • [49] Impact of Reactive Current Injection by Islanding Detection Techniques on the Voltage Quality of Distributed Generation
    Gupta, Pankaj
    Bhatia, R. S.
    Jain, D. K.
    2018 20TH NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2018,
  • [50] Vector jump relay on SIMULINK: implementation of anti-islanding techniques in distributed generation systems
    Finkler, Alcedir Luis
    Obregon, Luana
    de Campos, Mauricio
    Lenz, Joao Manoel
    Sausen, Paulo Sergio
    Romcy Sausen, Airam T. Z.
    REVISTA BRASILEIRA DE COMPUTACAO APLICADA, 2021, 13 (03): : 1 - 9