A well-type NaI(Tl)/BC404 phoswich detector for atmospheric radioxenon monitoring

被引:5
|
作者
Luo Fei [1 ]
Xiang Yongchun [1 ]
Gong Jian [1 ]
Ze Rende [1 ]
Yan Zhaotong [1 ]
Wang Qian [1 ]
Weng Kuiping [1 ]
Hao Fanhua [1 ]
Zeng Jun [1 ]
机构
[1] China Acad Engn Phys, Inst Nucl Phys & Chem, 64 MianShan Rd, Mianyang, Sichuan, Peoples R China
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2021年 / 986卷
关键词
Radioxenon; Nuclear explosion monitoring; Beta-gamma coincidence detection; Phoswich detector;
D O I
10.1016/j.nima.2020.164715
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The monitoring of radioxenon in the atmosphere is one of several methods to detect nuclear weapon tests as part of the Comprehensive Nuclear Test Ban Treaty. For ultra-low radioxenon detection, a phoswich detector with two scintillators coupled to a single photomultiplier was explored to simplify the time-based coincidence detection systems such as SAUNA and ARSA. We present a well-type NaI(Tl)/BC404 phoswich detector, newly developed by the Institute of Nuclear Physics and Chemistry, which consist of a thin BC404 cell to detect beta and conversion electrons, and a NaI(Tl) crystal to detect X-rays and gamma-rays. Moreover, the pulses of the detector were sampled and processed at 1GS/s with 10-bit ADC by a high-speed digitizer. In the preliminary experiments with various sources, the detector was test to have comparable sensitivity with the existing detectors in energy resolution, detection efficiency, background, memory effect and MDCs. The gamma resolution achieved 6.9% at 662keV. The coincidence efficiency of Xe-133 at 81keV region is about 71% while gas loss in the stainless tube and the valve was accounted. In addition, the MDC of Xe-133 was calculated by 0.2mBq/m(3) under current gas process capability.
引用
收藏
页数:6
相关论文
共 27 条
  • [21] Well-type NaI(Tl) detector efficiency using analytical technique and ANGLE 4 software based on radioactive point sources located out the well cavity
    El-Khatib, Ahmed M.
    Badawi, Mohamed S.
    Thabet, Abouzeid A.
    Jovanovic, Slobodan I.
    Gouda, Mona M.
    Mohamed, Moustafa M.
    Dlabac, Aleksandar D.
    Abd-Elzaher, Mohamed
    Mihaljevic, Nikola N.
    Abbas, Mahmoud I.
    CHINESE JOURNAL OF PHYSICS, 2016, 54 (03) : 338 - 346
  • [22] Digital instrumentation and management of dead time: First results on a NaI well-type detector setup
    Censier, B.
    Bobin, C.
    Bouchard, J.
    Aubineau-Laniece, I.
    APPLIED RADIATION AND ISOTOPES, 2010, 68 (7-8) : 1314 - 1319
  • [23] ABSOLUTE CALIBRATION OF A WELL-TYPE NAI-DETECTOR TO AN ACCURACY OF 0.3-0.1PERCENT
    MANNHART, W
    VONACH, H
    NUCLEAR INSTRUMENTS & METHODS, 1976, 136 (01): : 109 - 117
  • [24] MEASUREMENTS OF DISINTEGRATION RATES OF I125 SOURCES WITH A SINGLE WELL-TYPE NAI(TI) DETECTOR
    HORROCKS, DL
    NUCLEAR INSTRUMENTS & METHODS, 1975, 125 (01): : 105 - 111
  • [25] CALIBRATION OF A WELL-TYPE NAI(TI)-DETECTOR FOR ABSOLUTE COUNTING OF GASEOUS KR-85 AND XE-133
    CEJNAR, F
    KOVAR, I
    RADIOCHEMICAL AND RADIOANALYTICAL LETTERS, 1977, 30 (5-6): : 341 - 348
  • [26] MEASUREMENT OF THE GAMMA-RAY EMISSION RATE OF CD-109 WITH A WELL-TYPE NAI(T1) DETECTOR
    BALLAUX, C
    HUTCHINSON, JMR
    APPLIED RADIATION AND ISOTOPES, 1986, 37 (09) : 923 - 928
  • [27] MONTE-CARLO CALCULATION OF SELF-ABSORPTION OF GAMMA-RAYS IN A VOLUME-SHAPED SOURCE CONNECTING A FACE-TYPE AND A WELL-TYPE NAI-DETECTOR
    RIEPPO, R
    INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1976, 27 (11): : 605 - 607