Speech Perception Outcomes for Adult Cochlear Implant Recipients Using a Lateral Wall or Perimodiolar Array

被引:16
|
作者
Moran, Michelle [1 ,2 ,3 ,4 ]
Vandali, Andrew [1 ,5 ]
Briggs, Robert J. S. [1 ,2 ,3 ]
Dettman, Shani [1 ,3 ]
Cowan, Robert S. C. [1 ,3 ]
Dowell, Richard C. [1 ,2 ,3 ]
机构
[1] HEARing CRC, Melbourne, Vic, Australia
[2] Royal Victorian Eye & Ear Hosp, Melbourne, Vic, Australia
[3] Univ Melbourne, Melbourne, Vic, Australia
[4] Cochlear Ltd, Melbourne, Vic, Australia
[5] Bion Inst, Melbourne, Vic, Australia
关键词
Adults; Cochlear implants; Electrode array; Outcomes; Speech perception; HEARING PRESERVATION; CLINICAL-EVALUATION; STRAIGHT ELECTRODE; PERFORMANCE; INSERTION; DESIGN; IMPACT; SLIM; LOCATION; POSITION;
D O I
10.1097/MAO.0000000000002189
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Aim: To assess the speech perception outcomes of adult CI recipients with significant preimplant low frequency hearing, examining differences between perimodiolar and lateral wall electrode placement in order to provide clinical guidance for clinicians and surgeons. Methods: A prospective cohort study was undertaken identifying all adults who received a thin straight electrode array (TSEA) at the Royal Victorian Eye & Ear Hospital (RVEEH) from 2010 to 2015 and who had a preimplant low frequency pure tone median <= 70 dB HL (n = 63). A retrospective review was completed of the RVEEH database to identify a comparison group who had been implanted with a perimodiolar electrode array, comprising adults implanted between 2004 and 2011 (PM Group) with preimplant hearing equivalent to the TSEA group (n = 70). The TSEA Group were further divided into subgroups in which n = 19 used EAS (TSEA-EAS) and n = 44 who used electric-only hearing (TSEA-Standard). Results: There was no significant difference in median speech perception outcomes between the TSEA and PM Groups (TSEA 61.7%, PM 67.3%, p = 0.954). A significant difference was found between the TSEA-EAS and TSEA-Standard subgroups for median speech perception outcome (TSEA-EAS median 73.5%, TSEA-Standard median 58.3%, p = 0.043). Conclusions: Significant speech perception benefit following cochlear implantation was achieved with both the perimodiolar and lateral wall electrode arrays and no significant difference was found between outcomes with those array types in this population of adults with functional low frequency hearing pre-implant. Those that received a TSEA, had preserved hearing, and utilised an EAS sound processor performed better than their peers with a TSEA and electric-only hearing.
引用
收藏
页码:608 / 616
页数:9
相关论文
共 50 条
  • [21] Intracochlear Electrocochleography and Speech Perception Scores in Cochlear Implant Recipients
    Valenzuela, Carla V.
    Lichtenhan, Jeffery T.
    Lefler, Shannon M.
    Koka, Kanthaiah
    Buchman, Craig A.
    Ortmann, Amanda J.
    LARYNGOSCOPE, 2021, 131 (10): : E2681 - E2688
  • [22] Speech Perception and Production in Cochlear Implant Recipients with Pendred Syndrome
    Skrivan, Jiri
    Jurovcik, Michal
    Aksenovova, Zdenka
    Astl, Jaromir
    Pourova, Radka Kremlikova
    Dytrych, Petra
    Sieger, Tomas
    BALKAN MEDICAL JOURNAL, 2021, 38 (04) : 244 - 248
  • [23] Comparison of electrophysiological parameters between perimodiolar and lateral wall electrodes in paediatric cochlear implant users
    A. Zarowski
    A. Molisz
    E. A. M. Mylanus
    J. H. M. Miserus
    M. Leblans
    J. van Dinther
    J. Siebert
    E. F. Offeciers
    European Archives of Oto-Rhino-Laryngology, 2020, 277 : 2693 - 2699
  • [24] EFFECTIVENESS OF AN INTENSIVE SPEECH-PERCEPTION TRAINING-PROGRAM FOR ADULT COCHLEAR IMPLANT RECIPIENTS
    GAGNE, JP
    PARNES, LS
    HASSAN, R
    LAROCQUE, M
    VIDAS, S
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1991, 100 (09): : 700 - 707
  • [25] Long-term speech perception performance in prelingually deafened adult cochlear implant recipients
    Yoshida, Haruo
    Kanda, Yukihiko
    Satoh, Chisei
    Kumai, Yoshihiko
    Takahashi, Haruo
    COCHLEAR IMPLANTS INTERNATIONAL, 2023, 24 (05) : 243 - 249
  • [26] Comparison of electrophysiological parameters between perimodiolar and lateral wall electrodes in paediatric cochlear implant users
    Zarowski, A.
    Molisz, A.
    Mylanus, E. A. M.
    Miserus, J. H. M.
    Leblans, M.
    van Dinther, J.
    Siebert, J.
    Offeciers, E. F.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2020, 277 (10) : 2693 - 2699
  • [27] Audiologic Outcomes of Cochlear Implantation in Cochlear Malformations: A Comparative Analysis of Lateral Wall and Perimodiolar Electrode Arrays
    Schwartz, Nofrat
    Brown, Kevin D.
    Park, Lisa R.
    OTOLOGY & NEUROTOLOGY, 2020, 41 (10) : E1201 - E1206
  • [28] Exploring neurocognitive factors and brain activation in adult cochlear implant recipients associated with speech perception outcomes-A scoping review
    Beckers, Loes
    Tromp, Nikki
    Philips, Birgit
    Mylanus, Emmanuel
    Huinck, Wendy
    FRONTIERS IN NEUROSCIENCE, 2023, 17
  • [29] The Effect of Technology and Testing Environment on Speech Perception Using Telehealth With Cochlear Implant Recipients
    Goehring, Jenny L.
    Hughes, Michelle L.
    Baudhuin, Jacquelyn L.
    Valente, Daniel L.
    McCreery, Ryan W.
    Diaz, Gina R.
    Sanford, Todd
    Harpster, Roger
    JOURNAL OF SPEECH LANGUAGE AND HEARING RESEARCH, 2012, 55 (05): : 1373 - 1386
  • [30] Scalar Translocation Comparison Between Lateral Wall and Perimodiolar Cochlear Implant Arrays - A Meta-Analysis
    Jwair, Saad
    Prins, Adrianus
    Wegner, Inge
    Stokroos, Robert J.
    Versnel, Huib
    Thomeer, Hans G. X. M.
    LARYNGOSCOPE, 2021, 131 (06): : 1358 - 1368