Flow-injection chemiluminescence determination of fluoroquinolones

被引:47
|
作者
Rao, Y
Tong, Y
Zhang, XR [1 ]
Luo, GA
Baeyens, WRG
机构
[1] Tsing Hua Univ, Dept Chem, Beijing 100084, Peoples R China
[2] State Univ Ghent, Fac Pharmaceut Sci, B-9000 Ghent, Belgium
关键词
ofloxacin; norfloxacin; ciprofloxacin; lomefloxacin; chemiluminescence; flow-injection; cerium (IV);
D O I
10.1080/00032710008543113
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new flow-injection CL method was developed for the determination of fluoroquinolones including ofloxacin, norfloxacin, ciprofloxacin and lomefloxacin in pharmaceutical preparations, based on the chemiluminescence reaction of sulphite with cerium(IV) sensitized by these compounds. The linear ranges are 0.04 to 4.0 mu g ml(-1) for ofloxacin and 0.4 to 40.0 mu g ml(-1) for norfloxacin, ciprofloxacin and lomefloxacin, respectively. The detection limits are 0.016 mu g ml(-1) for ofloxacin and 0.16 mu g ml(-1) for norfloxacin, ciprofloxacin and lomefloxacin, respectively. The relative standard deviations (RSD) are 2.1 to 2.6% (n = 10) for these fluoroquinolones. The analytical procedure has been applied to the determination of the fluoroquinolones in pharmaceutical commercial formulations. The results are in agreement with those obtained by the official methods.
引用
收藏
页码:1117 / 1129
页数:13
相关论文
共 50 条
  • [11] Sensitive determination of synephrine by flow-injection chemiluminescence
    Li, Q
    Huang, CZ
    Huang, YM
    LUMINESCENCE, 2006, 21 (01) : 43 - 48
  • [12] Flow-injection chemiluminescence sensor for the determination of isoniazid
    Zhang, SC
    Li, H
    ANALYTICA CHIMICA ACTA, 2001, 444 (02) : 287 - 294
  • [13] Flow-injection chemiluminescence determination of formaldehyde in water
    Motyka, Kamil
    Onjia, Antonije
    Mikuska, Pavel
    Vecera, Zbynek
    TALANTA, 2007, 71 (02) : 900 - 905
  • [14] Flow-injection chemiluminescence determination of haemoglobin in the blood
    Traore, Zoumana Sekou
    Shah, Syed Mazhar
    Su, Xingguang
    LUMINESCENCE, 2013, 28 (01) : 56 - 62
  • [15] Flow-injection chemiluminescence determination of procaterol hydrochloride
    Rao, Zhi-Ming
    Zou, Ping
    Chen, Mei
    Xiu, Fu-Rong
    Chen, Yu-Lin
    Hong, Ke-Jun
    Guang Pu Xue Yu Guang Pu Fen Xi/Spectroscopy and Spectral Analysis, 2008, 28 (02): : 269 - 272
  • [16] A Flow-Injection Chemiluminescence Determination of Formaldehyde in Textiles
    Kanwal, Shamsa
    Ma, Qiang
    Fu, Xiaohong
    Yuan, Pingfan
    Su, Xingguang
    SPECTROSCOPY LETTERS, 2010, 43 (02) : 84 - 90
  • [17] Determination of diethylstilboestrol by flow-injection chemiluminescence immunoassay
    Wang, S.
    Li, L.
    Liang, Y.
    Zhao, Y.
    LUMINESCENCE, 2008, 23 (02) : 100 - 100
  • [18] Back Flow-Injection Spectrophotometric Determination of Selected Fluoroquinolones
    Barakat, Salem A.
    CURRENT ANALYTICAL CHEMISTRY, 2017, 13 (02) : 124 - 127
  • [19] Flow-injection chemiluminescence determination of melamine in urine and plasma
    Tang, Xiaoshuang
    Shi, Xiyan
    Tang, Yuhai
    Yue, Zhongjin
    He, Qiqi
    LUMINESCENCE, 2012, 27 (03) : 229 - 233
  • [20] Chemiluminescence determination of thioridazine hydrochloride by flow-injection analysis
    Kojlo, A
    Michalowski, J
    Wolyniec, E
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (01) : 85 - 91