Ultra-trace levels voltammetric determination of Pb2+ in the presence of Bi3+ at food samples by a Fe3O4@Schiff base Network1 modified glassy carbon electrode

被引:18
|
作者
Sarvestani, Mohammad Reza Jalali [1 ]
Madrakian, Tayyebeh [1 ]
Afkhami, Abbas [1 ]
机构
[1] Bu Ali Sina Univ, Fac Chem, Hamadan 6517838695, Iran
关键词
Pb2+; Covalent organic framework; Square wave anodic stripping voltammetry; Bismuth film electrode; Experimental design; SOLID-PHASE EXTRACTION; BOX-BEHNKEN DESIGN; ELECTROCHEMICAL DETERMINATION; STRIPPING ANALYSIS; LEAD TOXICITY; WATER SAMPLES; HEAVY-METALS; OPTIMIZATION; MERCURY; PB(II);
D O I
10.1016/j.talanta.2022.123716
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this research, a highly sensitive electrochemical sensor was developed for the square wave anodic stripping voltammetric determination of Pb2+ at ultra-trace levels. A Glassy carbon electrode was modified with an in-situ electroplated bismuth film and the nanocomposite of a recently synthesized melamine based covalent organic framework (schiff base network1 (SNW1)) and Fe3O4 nanoparticles (Fe3O4@SNW1). The obtained results exhibit clearly that combination of Fe3O4@SNW1 and in-situ electroplated bismuth film enhances the sensitivity of the modified electrode towards Pb2+ remarkably. A Plackett-Burman design was implemented for screening experimental factors to specify the significant variables influencing the sensitivity of the electroanalytical method. Afterward, the effective factors were optimized using Box-Behnken design (BBD). Under optimized conditions, the proposed electrode showed a linear response towards Pb(2+ )in the concentration range of 0.003-0.3 mu mol L-1 with the detection limit of 0.95 nmol L-1. The selectivity of the fabricated electrode towards different ionic species were checked out and no serious interference was observed. At the end, the application of the designed sensor in the determination of Pb2+ at 10 different edible specimens were investigated and the obtained recovery values were in the range of (95.56-106.64%) indicating the successful performance of the designed sensor.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Highly sensitive electrochemical determination of agomelatine in biological samples based on Cu nanoparticles/Schiff base network1 modified glassy carbon electrode: DFT and experimental studies
    Ajdari, Beheshteh
    Madrakian, Tayyebeh
    Sarvestani, Mohammad Reza Jalali
    Afkhami, Abbas
    TALANTA, 2025, 283
  • [2] Fe3O4/GO nanocomposite modified glassy carbon electrode as a novel voltammetric sensor for determination of bisphenol A
    Beigmoradi, Fariba
    Beitollahi, Hadi
    JOURNAL OF ELECTROCHEMICAL SCIENCE AND ENGINEERING, 2022, : 1205 - 1214
  • [3] Voltammetric Determination of Paracetamol using Polyvinyl Alcohol (PVA)-Fe3O4 Modified Glassy Carbon Electrode
    Andawiyah, Robi'atul
    Mulyasuryani, Ani
    Sulistyarti, Hermin
    2ND INTERNATIONAL CONFERENCE ON CHEMISTRY AND MATERIAL SCIENCE (IC2MS), 2020, 833
  • [4] Electrochemical determination of citalopram on new Schiff base functionalized magnetic Fe3O4 nanoparticle/MWCNTs modified glassy carbon electrode
    Keypour, Hassan
    Saremi, Shokoufeh Ghahri
    Veisi, Hojat
    Noroozi, Mohammad
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2016, 780 : 160 - 168
  • [5] Electrochemical behaviour of Sudan I at Fe3O4 nanoparticles modified glassy carbon electrode and its determination in food samples
    Yin, Huanshun
    Zhou, Yunlei
    Meng, Xiaomeng
    Tang, Tiantian
    Ai, Shiyun
    Zhu, Lusheng
    FOOD CHEMISTRY, 2011, 127 (03) : 1348 - 1353
  • [6] Simultaneous Voltammetric Detection of Acetaminophen and Caffeine Base on Cassava Starch-Fe3O4 Nanoparticles Modified Glassy Carbon Electrode
    Mulyasuryani, Ani
    Tjahjanto, Rachmat Triandi
    Andawiyah, Robi'atul
    CHEMOSENSORS, 2019, 7 (04)
  • [7] Adsorptive stripping voltammetric determination of dicyclomine hydrochloride at a glassy carbon electrode modified with silver decorated Fe3O4 nanocubes in pharmaceutical and biological samples
    Rawool, Chaitali R.
    Rajpurohit, Anuja S.
    Punde, Ninad S.
    Srivastava, Ashwini K.
    ANALYTICAL METHODS, 2018, 10 (12) : 1441 - 1451
  • [8] Determination of diltiazem in the presence of timolol in human serum samples using a nanoFe3O4@GO modified glassy carbon electrode
    Hasanzadeh, Mohammad
    Pournaghi-Azar, Mohammad Hossein
    Shadjou, Nasrin
    Jouyban, Abolghasem
    RSC ADVANCES, 2014, 4 (93): : 51734 - 51744
  • [9] Application of a 1-benzyl-4-ferrocenyl-1H-[1,2,3]-triazole/carbon nanotube modified glassy carbon electrode for voltammetric determination of hydrazine in water samples
    Beitollahi, Hadi
    Tajik, Somayeh
    Maleh, Hassan Karimi
    Hosseinzadeh, Rahman
    APPLIED ORGANOMETALLIC CHEMISTRY, 2013, 27 (08) : 444 - 450
  • [10] A novel electrochemical sensor based on magneto LDH/Fe3O4 nanoparticles @ glassy carbon electrode for voltammetric determination of tramadol in real samples
    Tayyebeh Madrakian
    Sakineh Alizadeh
    Morteza Bahram
    Abbas Afkhami
    Ionics, 2017, 23 : 1005 - 1015