The Retrofit Design for Water Network with Multiple Contaminants of Industrial Process

被引:1
|
作者
Pungthong, Kittichai [1 ]
Siemanond, Kitipat [1 ]
机构
[1] Chulalongkorn Univ, Petr & Petrocham Coll, Bangkok 10330, Thailand
关键词
D O I
10.3303/CET1545201
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Water is the important resources for process industry. The reduction of water usage decreases the capital cost for process industry. This paper presents a design model of water/wastewater network with multiple contaminants. The main purpose is minimizing the total fixed cost (TFC) and the total annual cost (TAC) of overall water network including annual cost of water usage and water treatment compared between two design models. The first model is retrofit design of water network model by a liner programming (LP) for design with treatment. The second model is simultaneous grassroots design of water/wastewater network with minimum TAC by a mixed-integer non-liner programming (MINLP). According to the main purpose, a non-linear programming (NLP) model is solved for good initial variables for the MINLP in the second model. This model uses data from published work. The result show the grassroots design of water/wastewater network can reduce TAC more than one from the retrofit design. All mathematical models of this work are solved by DICOPT as solver in General Algebraic Modelling System (GAMS).
引用
收藏
页码:1201 / 1206
页数:6
相关论文
共 50 条
  • [41] Retrofit design and economic optimization of an extractive distillation process
    Bauer, MH
    Stichlmair, J
    Koehler, J
    Schadler, N
    DISTILLATION AND ABSORPTION '97, VOLS 1 AND 2, 1997, (142): : 653 - 661
  • [42] Energy and exergy analysis for cryogenic process design/retrofit
    Threerachannarong, Nattawat
    Siemanond, Kitipat
    28TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, 2018, 43 : 379 - 384
  • [43] Crisp and Fuzzy Optimisation Approaches for Water Network Retrofit
    Hul, Seingheng
    Ng, Denny K. S.
    Tan, Raymond R.
    Chiang, Choon-Lai
    Foo, Dominic C. Y.
    CHEMICAL PRODUCT AND PROCESS MODELING, 2007, 2 (03):
  • [44] Design of water-using networks with multiple contaminants by determining concentration order of streams
    Pan, Chunhui
    Shi, Jing
    Liu, Zhiyong
    Huagong Xuebao/CIESC Journal, 2010, 61 (10): : 2644 - 2650
  • [45] Retrofit of water network with optimization of existing regeneration units
    Tan, Yin Ling
    Manan, Zainuddin Abdul
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2006, 45 (22) : 7592 - 7602
  • [46] Optimal design and retrofit of sensor network for linear processes
    Li, Bo
    Chen, Bingzhen
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2001, 41 (12): : 31 - 34
  • [47] Process intensification for the retrofit of a multicomponent distillation plant - An industrial case study
    Errico, Massimiliano
    Rong, Ben-Guang
    Tola, Giuseppe
    Turunen, Ilkka
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2008, 47 (06) : 1975 - 1980
  • [48] Multiobjective Optimization Using Goal Programming for Industrial Water Network Design
    Ramos, Manuel A.
    Boix, Marianne
    Montastruc, Ludovic
    Domenech, Serge
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2014, 53 (45) : 17722 - 17735
  • [49] Design, Optimization, and Retrofit of the Formic Acid Process I: Base Case Design and Dividing-Wall Column Retrofit
    da Cunha, Sergio
    Rangaiah, G. P.
    Hidajat, Kus
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (29) : 9554 - 9570
  • [50] Holistic Approach for Retrofit Design of Cooling Water Networks
    Reddy, C. C. S.
    Rangaiah, G. P.
    Long, Lim Wei
    Naidut, S. V.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2013, 52 (36) : 13059 - 13078