The Retrofit Design for Water Network with Multiple Contaminants of Industrial Process

被引:1
|
作者
Pungthong, Kittichai [1 ]
Siemanond, Kitipat [1 ]
机构
[1] Chulalongkorn Univ, Petr & Petrocham Coll, Bangkok 10330, Thailand
关键词
D O I
10.3303/CET1545201
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Water is the important resources for process industry. The reduction of water usage decreases the capital cost for process industry. This paper presents a design model of water/wastewater network with multiple contaminants. The main purpose is minimizing the total fixed cost (TFC) and the total annual cost (TAC) of overall water network including annual cost of water usage and water treatment compared between two design models. The first model is retrofit design of water network model by a liner programming (LP) for design with treatment. The second model is simultaneous grassroots design of water/wastewater network with minimum TAC by a mixed-integer non-liner programming (MINLP). According to the main purpose, a non-linear programming (NLP) model is solved for good initial variables for the MINLP in the second model. This model uses data from published work. The result show the grassroots design of water/wastewater network can reduce TAC more than one from the retrofit design. All mathematical models of this work are solved by DICOPT as solver in General Algebraic Modelling System (GAMS).
引用
收藏
页码:1201 / 1206
页数:6
相关论文
共 50 条
  • [1] Design of Water Network with Multiple Contaminants and Zero Discharge
    李英
    都健
    姚平经
    ChineseJournalofChemicalEngineering, 2003, (05) : 73 - 78
  • [2] Design of water network with multiple contaminants and zero discharge
    Li, Y
    Du, J
    Yao, PJ
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2003, 11 (05) : 559 - 564
  • [3] A robust method to obtain optimal and sub-optimal design and retrofit solutions of water utilization systems with multiple contaminants in process plants
    Bagajewicz, MJ
    Rivas, M
    Savelski, MJ
    COMPUTERS & CHEMICAL ENGINEERING, 2000, 24 (2-7) : 1461 - 1466
  • [4] Planning Model for the Design and/or Retrofit of Industrial Water Systems
    Faria, Debora C.
    Bagajewicz, Miguel J.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2011, 50 (07) : 3788 - 3797
  • [5] Optimum design of industrial water supply network with multiple resources
    Zhou W.
    Jiang W.
    Deng C.
    Feng X.
    Huagong Xuebao/CIESC Journal, 2018, 69 (06): : 2560 - 2566
  • [6] LP-based solution strategies for the optimal design of industrial water networks with multiple contaminants
    Teles, Joao
    Castro, Pedro M.
    Novals, Augusto Q.
    CHEMICAL ENGINEERING SCIENCE, 2008, 63 (02) : 376 - 394
  • [7] Algorithmic procedure to design water utilization systems featuring multiple contaminants in process plants
    Wang, DM
    Yang, FL
    Zhang, XW
    CHINESE JOURNAL OF CHEMICAL ENGINEERING, 2005, 13 (03) : 396 - 402
  • [8] Algorithmic Procedure to Design Water Utilization Systems Featuring Multiple Contaminants in Process Plants
    王东明
    杨凤林
    张兴文
    Chinese Journal of Chemical Engineering, 2005, (03) : 396 - 402
  • [9] Design water-using network with multiple contaminants by step by step linear programming
    Li, Baohong
    Fei, Weiyang
    Huagong Xuebao/Journal of Chemical Industry and Engineering (China), 2005, 56 (02): : 285 - 290
  • [10] Process integration design methods for water conservation and wastewater reduction in industryPart 2: Design for multiple contaminants
    Russell F. Dunn
    Henrik Wenzel
    Michael R. Overcash