Transcatheter closure of perimembranous ventricular septal defects using the amplatzer membranous VSD occluder: Immediate and midterm results of an international registry

被引:145
|
作者
Holzer, Ralf
de Giovanni, Jo
Walsh, Kevin P.
Tometzki, Andrew
Goh, T. H.
Hakim, Fakhri
Zabal, Carlos
de Lezo, Jose Suarez
Cao, Qi-Ling
Hijazi, Ziyad M.
机构
[1] Univ Chicago, Corner Childrens Hosp, Pritzker Sch Med, Dept Pediat,Sect Cardiol, Chicago, IL 60637 USA
[2] Childrens Hosp, Birmingham, W Midlands, England
[3] Our Ladys Hosp Sick Children, Dublin, Ireland
[4] Childrens Hosp, Bristol, Avon, England
[5] Royal Childrens Hosp, Melbourne, Vic, Australia
[6] Queen Alia Heart Inst, Amman, Jordan
[7] Inst Nacl Cardiol Ignacio Chavez, Mexico City, DF, Mexico
[8] Hosp Reina Sofia, Cordoba, Spain
关键词
perimembranous ventricular septal defect; catheterization; interventional;
D O I
10.1002/ccd.20659
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To report the immediate and midterm results of transcatheter closure of perimembranous ventricular septal defect (PmVSD) using the Amplatzer membranous VSD occluder (AMVSD). Methods: Between April 2002 and August 2004, 100 patients underwent an attempt of percutaneous device closure of PmVSD using the AMVSD in 24 international centers. The median age was 9.0 years (0.7-58 years) and the median weight was 27.5 kg (7-121 kg). Results: A device was successfully deployed in 93/100 (93%) patients. Reasons for procedural failure were an increased gradient across the left ventricle outflow tract in one patient, aortic regurgitation in 2 patients, and inability to securely position the device in 4 patients. The median VSD size by TEE was 7.0 mm (1.5-13 mm), median device size 10 mm (4-16 mm) and median fluoroscopy time 22.1 min (8.9-96.0 min). Weight below 10 kg (P = 0.0392), inlet extension of the VSD (P = 0.0139) and aortic cusp prolapse into the VSD (P = 0.0084) were significantly associated with a lower procedural success. Patients have been followed up for a median of 182 days (1-763 days). There were no procedure-related deaths. Complications were encountered in 29/100 (29%) patients, including rhythm or conduction anomalies in 13 patients (two with complete heart block requiring permanent pacemaker implantation), new or increased aortic (9 patients) or tricuspid (9 patients) regurgitation, most of which were classified as trivial or mild. Patients with a weight below 10 kg had a significantly higher incidence of adverse events than patients with a weight above 10 kg (58.3% versus 25.0%, P = 0.0285). Immediately after device release complete closure of the defect was present in 54/93 (58.1%) patients, increasing to 46/55 (83.6%) patients at 6-months follow-up (P = 0.0012). Left ventricle end-diastolic diameter decreased from a median of 44 mm prior to device closure to a median of 39 mm at 6-months postprocedure (P = 0.0015). Conclusion: Closure of PmVSDs using the AMVSD occluder is safe and effective. However, longer follow-up period is warranted prior to the wide spread use of this device. (c) 2006 Wiley-Liss, Inc.
引用
收藏
页码:620 / 628
页数:9
相关论文
共 50 条
  • [21] THE CLINICAL EVALUATION OF TRANSCATHETER CLOSURE OF PERIMEMBRANOUS VENTRICULAR SEPTAL DEFECTS WITH THE AMPLATZER DUCT OCCLUDER II
    Yu Zhiqing
    Fu Lijun
    Li Yun
    Zhang Yuqi
    Li Fen
    Huang Meirong
    Guo Ying
    HEART, 2011, 97
  • [22] Retraction Note: Transcatheter closure of perimembranous ventricular septal defects (VSD) with VSD occluder: early and mid-term results
    Yidong Wei
    Xian Wang
    Shouyan Zhang
    Lei Hou
    Yong Wang
    Yawei Xu
    Qi Sun
    Huaibing Zhao
    Heart and Vessels, 2014, 29 : 427 - 427
  • [23] Transcatheter Closure of Perimembranous Ventricular Septal Defect Using the Amplatzer Duct Occluder II
    Sun, Hongxiao
    Luo, Gang
    Du, Zhanhui
    Ji, Zhixian
    Pan, Silin
    CONGENITAL HEART DISEASE, 2021, 16 (02) : 151 - 157
  • [24] Transcatheter closure of perimembranous ventricular septal defects with the Amplatzer asymmetric ventricular septal defect occluder: preliminary experience in children
    Thanopoulos, BD
    Tsaousis, GS
    Karanasios, E
    Eleftherakis, NG
    Paphitis, C
    HEART, 2003, 89 (08) : 918 - 922
  • [25] Transcatheter closure of perimembranous ventricular septal defects with the amplatzer asymmetric ventricular septal defect occluder: Preliminary experience in children
    Thanopoulos, BD
    Tsaousis, GS
    Karanasios, E
    Stefanadis, C
    Sophia, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (06) : 473A - 473A
  • [26] Transcatheter Closure of Postoperative Residual Ventricular Septal Defects Using Amplatzer-Type Perimembranous VSD Occluders
    Zhang, Bo
    Liang, Jiali
    Zheng, Xiaozhou
    Jiang, Guanhua
    Yang, Zhe
    Zhang, Luying
    Zhang, Yong
    Sun, Haofeng
    JOURNAL OF INVASIVE CARDIOLOGY, 2013, 25 (08): : 402 - 405
  • [27] Transcatheter closure of large secundum atrial septal defects using the 40 mm Amplatzer septal occluder: Results of an international registry
    Lopez, K
    Dalvi, BV
    Balzer, D
    Bass, JL
    Momenah, T
    Cao, QL
    Hijazi, ZM
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (04) : 580 - 584
  • [28] Use of the Amplatzer muscular ventricular septal defect occluder for closure of perimembranous ventricular septal defects
    Szkutnik, M.
    Qureshi, S. A.
    Kusa, J.
    Rosenthal, E.
    Bialkowski, J.
    HEART, 2007, 93 (03) : 355 - 358
  • [29] Transcatheter closure of single muscular ventricular septal defects using the Amplatzer muscular VSD occluder: Initial results and technical considerations
    Hijazi, ZM
    Hakim, F
    Al-Fadley, F
    Abdelhamid, J
    Cao, QL
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2000, 49 (02) : 167 - 172
  • [30] Transcatheter Retrograde Closure of Perimembranous Ventricular Septal Defects in Children With the Amplatzer Duct Occluder II Device
    Koneti, Nageswara Rao
    Sreeram, Narayanswami
    Penumatsa, Raghava Raju
    Arramraj, Srinivas K.
    Karunakar, Vadlamudi
    Trieschmann, Uwe
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 60 (23) : 2421 - 2422