Relationship between corneal hysteresis (CH) as measured by ocular response analyzer (ORA) and corneal central thickness (CCT) as determined using Pentacam in childhood glaucoma (CG) patients

被引:0
|
作者
Perucho Gonzalez, Lucia [1 ]
Saenz-Frances, Federico [1 ]
Morales Fernendez, Laura [1 ]
Mendez-Hernandez, Carmen [1 ]
Martinez de la Casa, Jose Maria [1 ]
Perez Bartolome, Francisco [1 ]
Santos Bueso, Enrique [1 ]
Garcia Feijoo, Julian [1 ]
机构
[1] Clin San Carlos Univ Hosp, Ophthalmol, Madrid, Madrid, Spain
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
6472
引用
收藏
页数:3
相关论文
共 31 条
  • [1] The use of Ocular response analyzer (ORA) to show the relationship between central corneal thickness (CCT) to hysteresis and Excess ocular pressure (EOP)
    Shah, S
    Laiquzzaman, M
    Mantry, S
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U674 - U674
  • [2] Assessment of corneal hysteresis measured by the ocular response analyzer as a screening tool in patients with glaucoma
    Schweitzer, Justin A.
    Ervin, Molly
    Berdahl, John P.
    CLINICAL OPHTHALMOLOGY, 2018, 12 : 1809 - 1813
  • [3] Agreement Between Central Corneal Thickness Measured by Ultrasound Pachymetry and Minimal and Central Thicknesses Determined Using the Pentacam
    Saenz-Frances, F.
    Mendez-Hernandez, C.
    Martinez-de-la-Casa, J. M.
    Fernandez-Vidal, A. M.
    Escalada-Ferrandiz, A.
    Santos-Bueso, E.
    Fraile-Maya, J.
    Garcia-Sanchez, J.
    Garcia-Feijoo, J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [4] Effect of central corneal thickness and corneal hysteresis on tonometry as measured by dynamic contour tonometry, Ocular Response Analyzer, and Goldmann tonometry in glaucomatous eyes
    Annette, Hager
    Kristina, Loge
    Bernd, Schroeder
    Mark-Oliver, Fuellhas
    Wolfgang, Wiegand
    JOURNAL OF GLAUCOMA, 2008, 17 (05) : 361 - 365
  • [5] Optic disc area and correlation with central corneal thickness, corneal hysteresis and ocular pulse amplitude in glaucoma patients and controls: response
    Ang, Ghee Soon
    Nicholas, Simon
    Wells, Anthony
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (07): : 718 - 718
  • [6] Is there a relationship between central and peripheral corneal thickness in glaucoma patients?
    Fahim, MM
    Chanis, R
    Polikoff, L
    Stasi, K
    Danias, J
    Gagliuso, DJ
    Serle, JB
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 : U371 - U371
  • [7] The Relationship Between Corvis ST Tonometry Parameters and Ocular Response Analyzer Corneal Hysteresis
    Fujishiro, Takashi
    Matsuura, Masato
    Fujino, Yuri
    Murata, Hiroshi
    Tokumo, Kana
    Nakakura, Shunsuke
    Kiuchi, Yoshiaki
    Asaoka, Ryo
    JOURNAL OF GLAUCOMA, 2020, 29 (06) : 479 - 484
  • [8] Optic disc area and correlation with central corneal thickness, corneal hysteresis and ocular pulse amplitude in glaucoma patients and controls
    Insull, Elizabeth
    Nicholas, Simon
    Ang, Ghee Soon
    Poostchi, Ali
    Chan, Kenneth
    Wells, Anthony
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 38 (09): : 839 - 844
  • [9] Comparison of the corneal biomechanical properties with the Ocular Response Analyzer® (ORA) in African and Caucasian normal subjects and patients with glaucoma
    Detry-Morel, Michele
    Jamart, Jacques
    Hautenauven, Frederic
    Pourjavan, Sayeh
    ACTA OPHTHALMOLOGICA, 2012, 90 (02) : e118 - e124
  • [10] Agreement in central corneal thickness measurement between Corvis ST and ocular response analyzer
    Salouti, Ramin
    Razeghinejad, Reza
    Masihpour, Nasrin
    Ghoreyshi, Maryam
    Nowroozzadeh, M. Hossein
    INTERNATIONAL OPHTHALMOLOGY, 2020, 40 (10) : 2563 - 2567