Mixture model normalization for non-targeted gas chromatography/mass spectrometry metabolomics data

被引:30
|
作者
Reisetter, Anna C. [1 ]
Muehlbauer, Michael J. [2 ,3 ]
Bain, James R. [2 ,3 ]
Nodzenski, Michael [1 ]
Stevens, Robert D. [2 ,3 ]
Ilkayeva, Olga [2 ,3 ]
Metzger, Boyd E. [4 ]
Newgard, Christopher B. [2 ,3 ]
Lowe, William L., Jr. [4 ]
Scholtens, Denise M. [1 ]
机构
[1] Northwestern Univ, Feinberg Sch Med, Div Biostat, Dept Prevent Med, Chicago, IL 60611 USA
[2] Duke Univ, Med Ctr, Sarah W Stedman Nutr & Metab Ctr, Durham, NC 27701 USA
[3] Duke Univ, Sch Med, Durham, NC 27701 USA
[4] Northwestern Univ, Feinberg Sch Med, Div Endocrinol, Dept Med, Chicago, IL 60611 USA
来源
BMC BIOINFORMATICS | 2017年 / 18卷
关键词
Metabolomics; Non-targeted; Gas chromatography/mass spectrometry; GC/MS; Normalization; Batch effects; MASS-SPECTROMETRY; LARGE-SCALE; WEIGHT-LOSS; PREGNANCY; SAMPLES; PLASMA; SERUM; BIOINFORMATICS; BIOCONDUCTOR; METABOLITES;
D O I
10.1186/s12859-017-1501-7
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Metabolomics offers a unique integrative perspective for health research, reflecting genetic and environmental contributions to disease-related phenotypes. Identifying robust associations in population-based or large-scale clinical studies demands large numbers of subjects and therefore sample batching for gas-chromatography/ mass spectrometry (GC/MS) non-targeted assays. When run over weeks or months, technical noise due to batch and run-order threatens data interpretability. Application of existing normalization methods to metabolomics is challenged by unsatisfied modeling assumptions and, notably, failure to address batch-specific truncation of low abundance compounds. Results: To curtail technical noise and make GC/MS metabolomics data amenable to analyses describing biologically relevant variability, we propose mixture model normalization (mixnorm) that accommodates truncated data and estimates per-metabolite batch and run-order effects using quality control samples. Mixnorm outperforms other approaches across many metrics, including improved correlation of non-targeted and targeted measurements and superior performance when metabolite detectability varies according to batch. For some metrics, particularly when truncation is less frequent for a metabolite, mean centering and median scaling demonstrate comparable performance to mixnorm. Conclusions: When quality control samples are systematically included in batches, mixnorm is uniquely suited to normalizing non-targeted GC/MS metabolomics data due to explicit accommodation of batch effects, run order and varying thresholds of detectability. Especially in large-scale studies, normalization is crucial for drawing accurate conclusions from non-targeted GC/MS metabolomics data.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Simultaneous Quantification of Trehalose and Trehalose 6-Phosphate by Hydrophilic Interaction Chromatography/Electrospray Accurate Mass Spectrometry with Application in Non-Targeted Metabolomics
    Tao, Ye
    Rossez, Yannick
    Bortolus, Clovis
    Duma, Luminita
    Dubar, Faustine
    Merlier, Franck
    MOLECULES, 2023, 28 (08):
  • [42] Impact of sample containers on gas chromatography mass spectrometry based plasma untargeted and targeted metabolomics
    Chen, Minqi
    Liu, Zhongqiu
    Gong, Lingzhi
    PROTEOMICS, 2021, 21 (10)
  • [43] Development of a widely-targeted metabolomics method based on gas chromatography-mass spectrometry
    Wang Yating
    Yang Yang
    Sun Xiulan
    Ji Jian
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2023, 41 (06) : 520 - 526
  • [44] Gas chromatography-mass spectrometry and non-targeted metabolomics analysis reveals the flavor and nutritional metabolic differences of cow's milk fermented by Lactiplantibacillus plantarum with different phenotypic
    Zhang, Xueliang
    Zhang, Changliang
    Xiao, Luyao
    Wang, Xiaochan
    Ma, Kai
    Ji, Feng
    Azarpazhooh, Elham
    Ajami, Marjan
    Rui, Xin
    Li, Wei
    FOOD BIOSCIENCE, 2024, 60
  • [45] Non-Targeted Analysis Using Gas Chromatography-Mass Spectrometry for Evaluation of Chemical Composition of E-Vapor Products
    Shah, Niti H.
    Noe, Michael R.
    Agnew-Heard, Kimberly A.
    Pithawalla, Yezdi B.
    Gardner, William P.
    Chakraborty, Saibal
    McCutcheon, Nicholas
    Grisevich, Hannah
    Hurst, Thomas J.
    Morton, Michael J.
    Melvin, Matt S.
    Miller, John H.
    FRONTIERS IN CHEMISTRY, 2021, 9
  • [46] Gas Chromatography-Mass Spectrometry-Based Targeted Metabolomics of Hard Coral Samples
    Matthews, Jennifer L.
    Bartels, Natasha
    Doomun, Sheik Nadeem Elahee
    Davy, Simon K.
    De Souza, David P.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2023, (200):
  • [47] MetICA: independent component analysis for high-resolution mass-spectrometry based non-targeted metabolomics
    Youzhong Liu
    Kirill Smirnov
    Marianna Lucio
    Régis D. Gougeon
    Hervé Alexandre
    Philippe Schmitt-Kopplin
    BMC Bioinformatics, 17
  • [48] MetICA: independent component analysis for high-resolution mass-spectrometry based non-targeted metabolomics
    Liu, Youzhong
    Smirnov, Kirill
    Lucio, Marianna
    Gougeon, Regis D.
    Alexandre, Herve
    Schmitt-Kopplin, Philippe
    BMC BIOINFORMATICS, 2016, 17
  • [49] What computational non-targeted mass spectrometry-based metabolomics can gain from shotgun proteomics
    Hamzeiy, Hamid
    Cox, Juergen
    CURRENT OPINION IN BIOTECHNOLOGY, 2017, 43 : 141 - 146
  • [50] Discrimination of Adzuki Bean (Vigna angularis) Geographical Origin by Targeted and Non-Targeted Metabolite Profiling with Gas Chromatography Time-of-Flight Mass Spectrometry
    Kim, Tae Jin
    Park, Jeong Gon
    Ahn, Soon Kil
    Kim, Kil Won
    Choi, Jaehyuk
    Kim, Hyun Young
    Ha, Sun-Hwa
    Seo, Woo Duck
    Kim, Jae Kwang
    METABOLITES, 2020, 10 (03)