The effects of prosthetic foot type and visual alteration on postural steadiness in below-knee amputees

被引:16
|
作者
Arifin, Nooranida [1 ]
Abu Osman, Noor Azuan [1 ]
Ali, Sadeeq [1 ]
Abas, Wan Abu Bakar Wan [1 ]
机构
[1] Univ Malaya, Fac Engn, Dept Biomed Engn, Kuala Lumpur 50603, Malaysia
来源
BIOMEDICAL ENGINEERING ONLINE | 2014年 / 13卷
关键词
Postural steadiness; Computerized posturography; Prosthetic foot; Stability indexes; Transtibial amputees; Unperturbed standing; Visual input; BALANCE CONTROL; STABILITY; FALLERS; GAIT; SWAY;
D O I
10.1186/1475-925X-13-23
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background: Achieving independent upright posture has known to be one of the main goals in rehabilitation following lower limb amputation. The purpose of this study was to compare postural steadiness of below knee amputees with visual alterations while wearing three different prosthetic feet. Methods: Ten male below-knee amputees were instructed to stand quietly on the Biodex((R)) balance platform while wearing solid ankle cushion heel (SACH), single axis ( SA) and energy storage and release (ESAR) prosthetic foot under different visual input conditions ( eyes-opened and eyes-closed). The overall stability index (OSI), anterior-posterior stability index (APSI), and medial-lateral stability index (MLSI) were computed. Perceived balance assessment of each foot was evaluated using Activities-specific Balance Confidence (ABC) score. Results: The findings highlights that SACH showed lowest overall stability index ( indicating less body sway) during eyes-opened ( OSI: SACH = 1.09, SA = 1.58, ESAR = 1.59) and SA showed lowest overall stability index during eyes-closed ( OSI: SACH = 2.52, SA = 2.30, ESAR = 2.76) condition. However, overall stability indexes between foot types did not differ significantly during eyes-opened or eyes-closed ( p = 0.651). There was a trend of instability which occurred more in medial-lateral compared to anterior-posterior direction for all foot types, with significant result in ESAR foot ( eyes-opened: MLSI = 1.59, APSI = 0.65, p = 0.034; eyes closed: MLSI = 2.76, APSI = 1.80, p = 0.017, respectively). When comparing between visual conditions, stability score was significantly higher during eyes-closed compared to eyes-opened situations for SACH and ESAR foot ( eyes-closed vs opened; SACH OSI: 3.43 vs 1.71, p = 0.018 and MLSI: 3.43 vs 1.71, p = 0.018; ESAR OSI: 3.58 vs 1.86, p = 0.043 and APSI: 1.80 vs 0.65, p = 0.027). Conclusions: The results of this study suggested postural steadiness in below-knee amputees was not affected by the types of prosthetic foot during quiet upright standing, but was significantly affected when visual cues was absent.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Energy expenditure during ambulation in dysvascular and traumatic below-knee amputees. A comparison of five prosthetic feet
    Torburn, Leslie
    Powers, Christopher M.
    Guiterrez, Robert
    Perry, Jacquelin
    Journal of Rehabilitation Research & Development, 1995, 32 (02):
  • [42] INFLUENCE OF PROSTHETIC FOOT DESIGN ON SOUND LIMB LOADING IN ADULTS WITH UNILATERAL BELOW-KNEE AMPUTATIONS
    POWERS, CM
    TORBURN, L
    PERRY, J
    AYYAPPA, E
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1994, 75 (07): : 825 - 829
  • [43] ENERGY-EXPENDITURE DURING AMBULATION IN DYSVASCULAR AND TRAUMATIC BELOW-KNEE AMPUTEES - A COMPARISON OF 5 PROSTHETIC FEET
    TORBURN, L
    POWERS, CM
    GUITERREZ, R
    PERRY, J
    JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 1995, 32 (02): : 111 - 119
  • [44] PROSTHETIC FIT IN BELOW-KNEE AMPUTATION - EVALUATION WITH XERORADIOGRAPHY
    IRWIN, GAL
    FRIEDMAN, L
    SHAPIRO, D
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (01) : 99 - 101
  • [45] PROSTHETIC FITTING IMMEDIATELY AFTER BELOW-KNEE AMPUTATION
    KITOWSKI, VJ
    APPEL, MF
    HASLAM, T
    SOUTHERN MEDICAL JOURNAL, 1975, 68 (06) : 739 - 742
  • [46] PRE-PROSTHETIC AND ALTERNATIVE PROSTHETIC MANAGEMENT OF THE BELOW-KNEE AMPUTEE
    KRICK, H
    PHYSICAL THERAPY, 1986, 66 (05): : 773 - 773
  • [47] FUNCTIONAL-EVALUATION BY GAIT ANALYSIS OF VARIOUS ANKLE-FOOT ASSEMBLIES USED BY BELOW-KNEE AMPUTEES
    MIZUNO, N
    AOYAMA, T
    NAKAJIMA, A
    KASAHARA, T
    TAKAMI, K
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 1992, 16 (03) : 174 - 182
  • [48] THE DETACHABLE CAST PYLON TECHNIQUE FOR RIGID DRESSINGS ON BELOW-KNEE AMPUTEES
    TASHJIAN, EA
    RICHTER, KJ
    BACON, R
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1985, 66 (08): : 571 - 571
  • [49] JOINT TORQUE PATTERNS OF BELOW-KNEE AMPUTEES DURING RUNNING STANCE
    MILLER, DI
    MUNRO, CF
    JOURNAL OF BIOMECHANICS, 1985, 18 (03) : 236 - 236
  • [50] MODIFICATION OF TEMPORARY BELOW-KNEE SOCKETS FOR AMPUTEES WITH ABSENT OR DIMINISHED SENSATION
    MCPOIL, TG
    BERGTHOLDT, HT
    HUNT, GC
    PHYSICAL THERAPY, 1980, 60 (04): : 437 - 438