Wiener Filtering Using Object and Noise Power Spectra for CsI(Tl)-Scintillator Radiography Detectors

被引:0
|
作者
Lee, Eunae [1 ]
Kim, Dong Sik [1 ]
机构
[1] Hankuk Univ Foreign Studies, Dept Elect Engn, Yongin 17035, South Korea
基金
新加坡国家研究基金会;
关键词
IMAGE QUALITY CHARACTERIZATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The performance of the modulation transfer function (MTF) of indirect detectors, which is based on CsI(Tl) scintillator, is commonly worse than that of the direct detector, which is based on a-Se photoconductor, and can be improved using an image restoration technique. In this paper, the MTF performance of indirect detector were improved from an image restoration technique based on the Wiener filter. We used previously calculated noise power spectrum for the Wiener filter with the signal power spectrum calculated from the input image. Depending on the incident exposure of the acquired image, we could achieve an optimal MTF performance in terms of minimum mean square error.
引用
收藏
页数:4
相关论文
共 50 条
  • [31] Noise reduction using modified phase spectra and Wiener Filter
    Dang, Xin
    Nakai, Takayoshi
    2011 IEEE INTERNATIONAL WORKSHOP ON MACHINE LEARNING FOR SIGNAL PROCESSING (MLSP), 2011,
  • [32] Noise tolerant object recognition using gabor filtering
    Kamarainen, JK
    Kyrki, V
    Kälviäinen, H
    DSP 2002: 14TH INTERNATIONAL CONFERENCE ON DIGITAL SIGNAL PROCESSING PROCEEDINGS, VOLS 1 AND 2, 2002, : 1349 - 1352
  • [33] Speckle Noise Reduction in Images using Wiener Filtering and Adaptive Wavelet Thresholding
    Mohan, Rajesh R.
    Mridula, S.
    Mohanan, P.
    PROCEEDINGS OF THE 2016 IEEE REGION 10 CONFERENCE (TENCON), 2016, : 2860 - 2863
  • [34] Single Channel Speech Enhancement: using Wiener Filtering with Recursive Noise Estimation
    Upadhyay, Navneet
    Jaiswal, Rahul Kumar
    PROCEEDING OF THE SEVENTH INTERNATIONAL CONFERENCE ON INTELLIGENT HUMAN COMPUTER INTERACTION (IHCI 2015), 2016, 84 : 22 - 30
  • [35] Contrast-to-noise and exposure measurements of an aSi:H/CsI(Tl) flat-panel based digital radiography system using a QC chest phantom
    Liu, XM
    Shaw, CC
    Balter, P
    Kappadath, SC
    Lai, CJ
    MEDICAL IMAGING 2003: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2003, 5030 : 826 - 832
  • [36] Filtering of mixed Gaussian and impulsive noise using morphological contrast detectors
    Mendiola-Santibanez, Jorge D.
    Terol-Villalobos, Ivan R.
    IET IMAGE PROCESSING, 2014, 8 (03) : 131 - 141
  • [37] Characterization of Prototype Full-field Breast Tomosynthesis by Using a CMOS Array Coupled with a Columnar CsI(Tl) Scintillator
    Choi, Jae-Gu
    Park, Hye-Suk
    Kim, Ye-seul
    Choi, Young-Wook
    Ham, Tae-Hee
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (03) : 521 - 526
  • [38] Characterization of prototype full-field breast tomosynthesis by using a CMOS array coupled with a columnar CsI(Tl) scintillator
    Jae-Gu Choi
    Hye-Suk Park
    Ye-seul Kim
    Young-Wook Choi
    Tae-Hee Ham
    Hee-Joung Kim
    Journal of the Korean Physical Society, 2012, 60 : 521 - 526
  • [39] FLOW MONITOR FOR ACTINIDE SOLUTIONS BY SIMULTANEOUS ALPHA-COUNTING AND BETA(GAMMA)-COUNTING USING A CSI(TL) SCINTILLATOR
    USUDA, S
    ABE, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1992, 321 (1-2): : 242 - 246
  • [40] SINGLE-CHANNEL WIENER FILTERING OF DETERMINISTIC SIGNALS IN STOCHASTIC NOISE USING THE PANORAMA
    Douglas, Scott C.
    Mandic, Danilo P.
    2017 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2017, : 4182 - 4186