Wiener Filtering Using Object and Noise Power Spectra for CsI(Tl)-Scintillator Radiography Detectors

被引:0
|
作者
Lee, Eunae [1 ]
Kim, Dong Sik [1 ]
机构
[1] Hankuk Univ Foreign Studies, Dept Elect Engn, Yongin 17035, South Korea
基金
新加坡国家研究基金会;
关键词
IMAGE QUALITY CHARACTERIZATION;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The performance of the modulation transfer function (MTF) of indirect detectors, which is based on CsI(Tl) scintillator, is commonly worse than that of the direct detector, which is based on a-Se photoconductor, and can be improved using an image restoration technique. In this paper, the MTF performance of indirect detector were improved from an image restoration technique based on the Wiener filter. We used previously calculated noise power spectrum for the Wiener filter with the signal power spectrum calculated from the input image. Depending on the incident exposure of the acquired image, we could achieve an optimal MTF performance in terms of minimum mean square error.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] A New Columnar CsI(Tl) Scintillator for iQID detectors
    Han, Ling
    Miller, Brian W.
    Barber, H. Bradford
    Nagarkar, Vivek V.
    Furenlid, Lars R.
    MEDICAL APPLICATIONS OF RADIATION DETECTORS IV, 2014, 9214
  • [2] Image Restoration for CsI(Tl)-Scintillator Mammography Detectors
    Kim, Dong Sik
    Lee, Eunae
    2019 INTERNATIONAL CONFERENCE ON ELECTRONICS, INFORMATION, AND COMMUNICATION (ICEIC), 2019, : 432 - 433
  • [3] Improvement of the modulation transfer function of CsI(Tl)-scintillator mammography detectors
    Kim D.S.
    Lee E.
    IEIE Transactions on Smart Processing and Computing, 2020, 9 (01): : 33 - 40
  • [4] Characterization of CsI(Tl) and LYSO(Ce) scintillator detectors by measurements and Monte Carlo simulations
    Mouhti, I.
    Elanique, A.
    Messous, M. Y.
    Benahmed, A.
    McFee, J. E.
    Elgoub, Y.
    Griffith, P.
    APPLIED RADIATION AND ISOTOPES, 2019, 154
  • [5] Pixelated Columnar CsI:Tl Scintillator for High Resolution Radiography and Cone-Beam CT
    Miller, Stuart R.
    Singh, Bipin
    Marshall, Matthew S. J.
    Brown, Conner
    Sheth, Niral
    Shi, Gengxin
    Siewerdsen, Jeffrey H.
    Zbijewski, Wojciech
    Nagarkar, Vivek V.
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [6] THE RECONSTRUCTION OF THE NEUTRON-SPECTRA FROM THE DATA OBTAINED USING CSI(TL)-BASED SCINTILLATION DETECTORS
    BOGOMOLOV, AV
    GUDIMA, KK
    MYAGKOVA, IN
    RYUMIN, SP
    VESTNIK MOSKOVSKOGO UNIVERSITETA SERIYA 3 FIZIKA ASTRONOMIYA, 1994, 35 (03): : 81 - 83
  • [7] 2x2 Oversampling in Digital Radiography Imaging for CsI-based Scintillator Detectors
    Kim, Dong Sik
    Kim, Eun
    Lee, Eunae
    Shin, Choul Woo
    MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [8] ENERGY RESOLUTION OF CSI(TL)-SCINTILLATOR+ SILICON-PHOTODIODE DETECTORS OF GAMMA-RADIATION
    GRISHAEV, SI
    IGNATOV, SM
    LISURENKO, VA
    MASLENNIKOV, LA
    TISNEK, NI
    URUTSKOEV, LI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 1994, 37 (02) : 150 - 152
  • [9] A Novel Speech Enhancement Method Using Power Spectra Smooth in Wiener Filtering
    Bao, Feng
    Dou, Hui-jing
    Jia, Mao-shen
    Bao, Chang-chun
    2014 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA), 2014,
  • [10] Noise power spectrum of the fixed pattern noise in digital radiography detectors
    Kim, Dong Sik
    Kim, Eun
    MEDICAL PHYSICS, 2016, 43 (06) : 2765 - 2773