Calibration of the two microphone transfer function method to measure acoustical impedance in a wide frequency range

被引:0
|
作者
Boonen, R. [1 ]
Sas, P. [1 ]
机构
[1] Katholieke Univ Leuven, Dept Mech Engn, B-3001 Heverlee, Belgium
关键词
D O I
暂无
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The acoustical impedance of a component is one of its most important characteristics. It is needed when acoustical simulations using lumped elements or electrical analog circuits are carried out. The calibration procedure for the two microphone transfer function method described in ISO 10534-2 is not sufficiently accurate in most cases. In this paper, a new calibration method for the two microphone transfer function method has been proposed such that acoustical impedances can be measured with high accuracy over a wide frequency range. In this method, the estimation of the speed of sound has been eliminated. Next, in the calibration of the sensor mismatch, the deviation in sensor position after interchanging the pressure sensors has been taken into account. Finally, a recursive procedure has been proposed to refine the microphone position calibration. This refinement can be continued until the required calibration accuracy has been obtained.
引用
收藏
页码:325 / 336
页数:12
相关论文
共 50 条
  • [31] A COMPARISON OF SINGLE FREQUENCY AND WIDE FREQUENCY-RANGE IMPEDANCE TESTS FOR PAINTED METALS
    WALTER, GW
    CORROSION SCIENCE, 1990, 30 (6-7) : 617 - 629
  • [32] IN-VITRO MEASUREMENT OF TISSUE IMPEDANCE OVER A WIDE FREQUENCY RANGE
    LUDT, H
    HERRMANN, HD
    BIOPHYSIK, 1973, 10 (04): : 337 - 345
  • [33] IMPACT OF BREATHING CYCLE AND FREQUENCY-RANGE ON TRANSFER IMPEDANCE
    LUTCHEN, KR
    EVERETT, JR
    HABIB, RH
    JACKSON, AC
    FASEB JOURNAL, 1991, 5 (04): : A377 - A377
  • [34] Band Calibration of Joint Dual VCOs Covering Wide Frequency Range
    Li, Tiehu
    Zhang, Ruitao
    PROCEEDINGS OF 2016 IEEE INTERNATIONAL CONFERENCE ON INTEGRATED CIRCUITS AND MICROSYSTEMS (ICICM), 2016, : 65 - 69
  • [35] Wide energy range efficiency calibration method for Ge detectors
    Molnár, GL
    Révay, Z
    Belgya, T
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 489 (1-3): : 140 - 159
  • [36] Admittance-to-Digital-Impedance Converter for Wide-Frequency-Range Impedance Measurement System
    Lin, Hao-Wei
    Su, Chia-Ning
    Chen, Tse-An
    Chen, Yi-Chen
    Syu, Mei-Jywan
    Wei, Chia-Ling
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [37] Instability of the voltage transfer function for an MR103 microphone in a coupler calibration technique
    Horiuchi, R
    Fujimori, T
    Sato, S
    JOURNAL OF SOUND AND VIBRATION, 2003, 266 (05) : 981 - 991
  • [38] Delay calibration method for precise and accurate two way satellite time and frequency transfer
    Imae, M
    Aida, M
    Gotoh, T
    Shibuya, Y
    Kurihara, N
    2002 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS, CONFERENCE DIGEST, 2002, : 450 - 451
  • [39] Application of the two-microphone method for in-situ ground impedance measurements
    Kruse, Roland
    ACTA ACUSTICA UNITED WITH ACUSTICA, 2007, 93 (05) : 837 - 842
  • [40] Perceptual simultaneity range as a function of frequency separation and frequency range for two tones
    Okazaki, Satoshi
    Ichikawa, Makoto
    Tsuzaki, Minoru
    ACOUSTICAL SCIENCE AND TECHNOLOGY, 2019, 40 (06) : 367 - 373