Subaperture stitching interferometry for testing mild aspheres

被引:56
|
作者
Murphy, Paul [1 ]
Fleig, Jon [1 ]
Forbes, Greg [1 ]
Miladinovic, Dragisha [1 ]
DeVries, Gary [1 ]
O'Donohue, Stephen [1 ]
机构
[1] QED Technol, 1040 Univ Ave, Rochester, NY 14607 USA
来源
关键词
interferometry; subaperture stitching; metrology; asphere; SSI (R);
D O I
10.1117/12.680473
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Interferometric tests of aspheres have traditionally relied on so-called "null correctors". These usually require significant time and expense to design and fabricate, and are specific to a particular asphere prescription. What's more, they are tedious to align and calibrate. Aspheres can also be tested without null correction (using a spherical wavefront), but such capability is extremely limited. A typical interferometer can acquire only a few micrometers of fourth-order aspheric departure due to high-density interference fringes. Furthermore, standard software packages do not compensate for the impact upon a non-null measurement of (i) the part's aspheric shape or (ii) the interferometer's optical aberrations. While fringe density and asphere compensation severely limit the practical utility of a non-null asphere measurement, subaperture stitching can directly address these issues. In 2004, QED Technologies introduced the Subaperture Stitching Interferometer (SSI (R)) to automatically stitch spherical surfaces (including hemispheres). The system also boosts accuracy with in-line calibration of systematic errors. We have recently added aspheric capability, extending non-null aspheric test capability by an order of magnitude or more. As demonstrated in the past on annular zones of nearly nulled data, subaperture stitching can extend the testable aspheric departure. We present a more generally applicable and robust method of stitching non-null aspheric phase measurements. By exploiting novel compensation schemes and in-line system error calibration, our subaperture stitching system can provide significantly better accuracy and increased testable aspheric departure over an unstitched non-null test. Examples of stitched non-null tests are analyzed in this paper, and cross-tested against corresponding null tests.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Iterative algorithm for subaperture stitching interferometry for general surfaces
    Chen, SY
    Li, SY
    Dai, YF
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2005, 22 (09) : 1929 - 1936
  • [22] Applications of subaperture stitching interferometry for very large mirrors
    Burge, James H.
    Zhao, Chunyu
    MODERN TECHNOLOGIES IN SPACE-AND GROUND-BASED TELESCOPES AND INSTRUMENTATION II, 2012, 8450
  • [23] Positioning system and lattice design for subaperture stitching interferometry
    Kredba, Jan
    Psota, Pavel
    OPTICS AND MEASUREMENT INTERNATIONAL CONFERENCE 2016, 2016, 10151
  • [24] Annular subaperture interferometry for high-departure aspheres using paraboloidal parameterization
    Nowicki, Keith
    Wagner, Kelvin
    APPLIED OPTICS, 2019, 58 (12) : 3282 - 3292
  • [25] Measurement of large aspheric surfaces by annular subaperture stitching interferometry
    王孝坤
    王丽辉
    殷龙海
    张斌智
    范镝
    张学军
    ChineseOpticsLetters, 2007, (11) : 645 - 647
  • [26] Subaperture stitching interferometry with reduced reference errors for ultrasmooth surfaces
    Xu, Xudong
    Huang, Qiushi
    Shen, Zhengxiang
    Wang, Zhanshan
    ADVANCES IN METROLOGY FOR X-RAY AND EUV OPTICS VI, 2016, 9962
  • [27] Testing asphere by subaperture stitching interferometric method
    Wang, Xiao-Kun
    Wang, Li-Hui
    Zhang, Xue-Jun
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2007, 15 (02): : 192 - 198
  • [28] Testing of large optical surfaces with subaperture stitching
    Chen, Shanyong
    Li, Shengyi
    Dai, Yifan
    Zheng, Ziwen
    APPLIED OPTICS, 2007, 46 (17) : 3504 - 3509
  • [29] Precision asphere polishing with MRF technology and Subaperture Stitching Interferometry
    Gogler, Slawomir
    Bieszczad, Grzegorz
    Krupinski, Michal
    PHOTONICS LETTERS OF POLAND, 2013, 5 (04) : 128 - 130
  • [30] Subaperture stitching test for large aperture mild acylinders
    Kong, Lingwei
    Chen, Shanyong
    OPTICS COMMUNICATIONS, 2020, 455