Establishing tumour tracking accuracy in free-breathing respiratory gated SBRT of lung cancer

被引:0
|
作者
Wen, Chuan-Dong [1 ]
Wong, C. [1 ]
Ackerly, T. [1 ]
Ruben, J. [1 ]
Millar, J. [1 ]
机构
[1] Alfred Hosp, William Buckland Radiotherapy Ctr, Melbourne, Vic 3004, Australia
关键词
SYSTEM; MOTION;
D O I
10.1088/1742-6596/489/1/012041
中图分类号
O59 [应用物理学];
学科分类号
摘要
Free-breathing respiratory gated SBRT of surgically inoperable lung cancer has been clinically commissioned. This study was to establish the tumour tracking accuracy under clinical conditions based on an implanted fiducial marker. A Visicoil (TM) marker embedded in tissue-equivalent material mounted in a phantom (ET Gating Phantom (TM) Brainlab) driven by a patient's breathing data was treated with the ExacTrac (TM) system. This one-dimensional moving marker represented a tumour motion in superior-inferior (S-I) direction measured through 4DCT study of the same patient. Both Gafchromic (TM) films and the stereoscopic kV images were used for tracking the position of the marker. For tumour motion at magnitudes of 10, 20 and 29 mm and treated with corresponding gate widths of 50%, 33% and 20% of free breathing amplitude, the implanted marker was able to be tracked with a deviation <= 1.53 mm to its planned position.
引用
收藏
页数:5
相关论文
共 50 条
  • [41] Utilization of Hysteresis Motion as a Marker for Tumor Margin in a Free-Breathing Lung
    Zhao, T.
    White, B.
    Low, D.
    MEDICAL PHYSICS, 2011, 38 (06) : 3467 - +
  • [42] The effect of breathing irregularities on quantitative accuracy of respiratory gated PET/CT
    Teo, Boon-Keng
    Saboury, Babak
    Munbodh, Reshma
    Scheuermann, Joshua
    Torigian, Drew A.
    Zaidi, Habib
    Alavi, Abass
    MEDICAL PHYSICS, 2012, 39 (12) : 7390 - 7397
  • [43] Effect of breathing irregularities on the quantitative accuracy of respiratory gated PET/CT
    Teo, Boon-Keng
    Saboury, Babak
    Scheuermann, Joshua
    Torigian, Drew
    Karp, Joel
    Alavi, Abass
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [44] Implementation of free breathing respiratory amplitude-gated treatments
    Hickling, Susannah V.
    Veres, Andrew J.
    Moseley, Douglas J.
    Grams, Michael P.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2021, 22 (06): : 119 - 129
  • [45] Slice-specific tracking for free-breathing diffusion tensor cardiac MRI
    Xu, Xi
    Hu, Junpu
    Zheng, Yijia
    Liu, Yuanyuan
    Cui, Zhuoxu
    Liang, Dong
    Zhu, Yanjie
    NMR IN BIOMEDICINE, 2023, 36 (08)
  • [46] Quantification of Myocardial Perfusion Using Free-Breathing MRI and Prospective Slice Tracking
    Pedersen, Henrik
    Kelle, Sebastian
    Ringgaard, Steffen
    Schnackenburg, Bernhard
    Nagel, Eike
    Nehrke, Kay
    Kim, Won Yong
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (03) : 734 - 738
  • [47] FREE-BREATHING RESPIRATORY-NAVIGATOR-GATED 2D RADIAL MR FINGERPRINTING OF THE TRANSPLANTED HEART AT 3T
    Calarnou, Pauline
    Ogier, Augustin
    Abdurashidova, Tamila
    Ledoux, Jean-Baptiste
    Yerly, Jerome
    Hullin, Roger
    van Heeswijk, Ruud
    SWISS MEDICAL WEEKLY, 2024, 154 : 60S - 61S
  • [48] Automatic Respiratory Phase Identification and Mismatch Correction for Free-breathing PET/CT
    Wang, Jizhe
    Feng, Tao
    Zhu, Wentao
    Dong, Yun
    Li, Hongdi
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [49] Synchronized cardiac and respiratory sparsity for rapid free-breathing cardiac cine MRI
    Li Feng
    Leon Axel
    Jian Xu
    Daniel K Sodickson
    Ricardo Otazo
    Journal of Cardiovascular Magnetic Resonance, 16 (Suppl 1)
  • [50] Respiratory self-gating for free-breathing magnetization transfer MRI of the abdomen
    Li, Weiguo
    Zhang, Zhuoli
    Li, Kangan
    Jin, Ning
    Zhang, Yue
    Zhang, Tianjing
    Miller, Frank H.
    Larson, Andrew C.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (06) : 2249 - 2254