CineECG: A novel method to image the average activation sequence in the heart from the 12-lead ECG

被引:9
|
作者
Boonstra, Machteld J. [1 ]
Brooks, Dana H. [2 ]
Loh, Peter [1 ]
van Dam, Peter M. [1 ,3 ]
机构
[1] Univ Utrecht, Univ Med Ctr Utrecht, Dept Cardiol, Div Heart & Lungs, Utrecht, Netherlands
[2] Northeastern Univ, Elect & Comp Engn, Boston, MA 02115 USA
[3] ECG Excellence BV, Nieuwerbrug Aan Den Rijn, Netherlands
关键词
Electrocardiogram; Vectorcardiogram; Cardiac modeling; Average activation sequence; Cardiac isochrones; CineECG; ECG imaging; Inverse ECG; OF-CARDIOLOGY-FOUNDATION; PREMATURE VENTRICULAR CONTRACTIONS; ASSOCIATION ELECTROCARDIOGRAPHY; ARRHYTHMIAS COMMITTEE; SCIENTIFIC STATEMENT; CLINICAL CARDIOLOGY; AHA/ACCF/HRS RECOMMENDATIONS; VARIABILITY; STANDARDIZATION; LOCALIZATION;
D O I
10.1016/j.compbiomed.2021.105128
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
The standard 12-lead electrocardiogram (ECG) is a diagnostic tool to asses cardiac electrical activity. The vectorcardiogram is a related tool that represents that activity as the direction of a vector. In this work we investigate CineECG, a new 12-lead ECG based analysis method designed to directly estimate the average cardiac anatomical location of activation over time. We describe CineECG calculation and a novel comparison parameter, the average isochrone position (AIP). In a model study, fourteen different activation sequences were simulated and corresponding 12-lead ECGs were computed. The CineECG was compared to AIP in terms of location and direction. In addition, 67-lead body surface potential maps from ten patients were used to study the sensitivity of CineECG to electrode mispositioning and anatomical model selection. Epicardial activation maps from four patients were used for further evaluation. The average distance between CineECG and AIP across the fourteen sequences was 23.7 +/- 2.4 mm, with significantly better agreement in the terminal (27.3 +/- 5.7 mm) versus the initial QRS segment (34.2 +/- 6.1 mm). Up to four cm variation in electrode positioning produced an average distance of 6.5 +/- 4.5 mm between CineECG trajectories, while substituting a generic heart/torso model for a patient-specific one produced an average difference of 6.1 +/- 4.8 mm. Dominant epicardial activation map features were recovered. Qualitatively, CineECG captured significant features of activation sequences and was robust to electrode misplacement. CineECG provides a realistic representation of the average cardiac activation in normal and diseased hearts. In particular, the terminal segment of the CineECG might be useful to detect pathology.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Detection of nonvisible T wave alternans from digital 12-lead ECG
    Burattini, L
    Zareba, W
    Moss, AJ
    JOURNAL OF ELECTROCARDIOLOGY, 1996, 29 : 169 - 169
  • [42] Assessment of cardiac stress from massive pulmonary embolism with 12-lead ECG
    Daniel, LR
    Courtney, DM
    Kline, JA
    CHEST, 2001, 120 (02) : 474 - 481
  • [43] Synthesis of 12-Lead ECG from a Reduced Lead Set using Singular Value Decomposition
    Padhy, Sibasankar
    Dandapat, S.
    2015 IEEE POWER, COMMUNICATION AND INFORMATION TECHNOLOGY CONFERENCE (PCITC-2015), 2015, : 316 - 320
  • [44] Comparison of 12-lead ECG data from two different electrocardiographs.
    Ward, C
    Oliver, S
    Amakye, D
    Cornelissen, K
    Hedge, A
    Owen, J
    CLINICAL PHARMACOLOGY & THERAPEUTICS, 2002, 71 (02) : P89 - P89
  • [45] Electrical ventricular dyssynchrony by 12-lead ECG vs. mechanical activation of LV by STE
    Leinveber, P.
    Meluzin, J.
    Halamek, J.
    Jurak, P.
    Matejkova, M.
    Lipoldova, J.
    Novak, M.
    EUROPEAN HEART JOURNAL, 2018, 39 : 1216 - 1217
  • [46] Clinical Characteristics and Outcomes in Patients With Congestive Heart Failure and Low Voltage 12-Lead Ecg
    Mustafa, Mohammed
    Tawfellos, George
    White, Casey
    Harris, Erin
    Oredegbe, Al-Ameen
    Torosoff, Mikhail
    CIRCULATION, 2022, 146
  • [47] Heart rate and risk of death among patients with Pulmonary Hypertension: A 12-lead ECG analysis
    Bouchery-Bardet, Helene
    Creveuil, Christian
    Bauer, Fabrice
    Beygui, Farzin
    Champ-Rigot, Laure
    Saloux, Eric
    Labombarda, Fabien
    Roule, Vincent
    Sabatier, Remi
    Legallois, Damien
    Zalcman, Gerard
    Bergot, Emmanuel
    Milliez, Paul
    RESPIRATORY MEDICINE, 2017, 132 : 42 - 49
  • [48] DETECTION OF ACUTE MYOCARDIAL ISCHEMIC INJURY FROM THE 12-LEAD ECG USING A NOVEL CARDIAC ELECTRICAL BIOMARKER
    Schreck, David Michael
    Fishberg, Robert
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1663 - A1663
  • [49] Early acute rejection in heart allografts: QT-Alterations in the 12-lead surface ECG
    Tenderich, G
    Jahanyar, J
    Hornik, L
    Reif, S
    Deyerling, W
    Mannebach, H
    Koerfer, R
    Koerner, MM
    TRANSPLANTATION, 1999, 67 (07) : S112 - S112
  • [50] Underestimation of duration of ventricular activation by 12-lead ECG compared with direct measurement of activation duration derived from implanted pacemaker leads
    Duncan, Alison M.
    Lim, Eric
    Mebrate, Yoseph
    Wong, Tom
    Gibson, Derek G.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 152 (01) : 35 - 42