Isotopic Scintigraphy in Intrathecal Drug Delivery Failure: A Single-Institution Case Series
被引:2
|作者:
Delhaas, Elmar M.
[1
,2
]
van Assema, Danielle M. E.
[2
]
Froberg, Alida C.
[2
]
Zwezerijnen, Ben G. J. C.
[3
]
Harhangi, Biswadjiet S.
[4
]
Frankema, Sander P. G.
[1
]
Huygen, Frank J. P. M.
[1
]
van der Lugt, Aad
[2
]
机构:
[1] Erasmus MC, Ctr Pain Med, POB 2040, NL-3000 CA Rotterdam, Netherlands
[2] Erasmus MC, Dept Radiol & Nucl Med, Rotterdam, Netherlands
[3] Univ Amsterdam, Dept Radiol & Nucl Med, Med Ctr, Amsterdam, Netherlands
[4] Erasmus MC, Dept Neurosurg, Rotterdam, Netherlands
来源:
NEUROMODULATION
|
2021年
/
24卷
/
07期
关键词:
In-111-DTPA SPECT-CT;
computed tomography;
diagnostic imaging;
intrathecal drug delivery;
scintigraphy;
therapy failure;
BACLOFEN THERAPY;
COMPUTED-TOMOGRAPHY;
MALFUNCTION;
SPASTICITY;
INFUSION;
COMPLICATIONS;
D O I:
10.1111/ner.13275
中图分类号:
R-3 [医学研究方法];
R3 [基础医学];
学科分类号:
1001 ;
摘要:
Background The aim of this study was to assess the feasibility and diagnostic accuracy of an optimized(111)Indium-diethylenetriamine-penta-acetic-acid single-photon-emission computed tomography (CT) (In-111-DTPA SPECT-CT) examination in patients with suspected intrathecal drug delivery (ITDD) failure. Materials and Methods Retrospective analysis of routinely collected observational data from a case series of patients in the setting of the academic Center for Pain Medicine, Departments of Radiology and Nuclear Medicine and Neurosurgery. Twenty-seven patients participated between January 2014 and January 2019. Thirty-six optimized examinations including standardized pump flow rate with additional SPECT-CT imaging and a stepwise standardized analysis were performed. A 10 mL mixture of medication and 20 MBq 111In-DTPA was injected into the pump reservoir. Planar and SPECT-CT images were acquired at 24, 48, and 72 hours (h) after injection and at 96 hours and/or seven days, if needed. All images were reassessed by the first two authors using an optimized procedure. Results and Conclusions Twenty-two abnormalities were identified in 21 examinations, with these abnormalities consisting of leakage (n= 7), spinal catheter obstruction (n= 7), and cerebrospinal fluid flow obstruction (n= 8). Interventions (n= 19) confirmed the cause of ITDD failure. A false-positive finding at follow-up (n= 1) and a false-negative finding (n= 1) were encountered. Sensitivity was 95% (20/21) and the specificity 93% (14/15). A significant difference (p < 0.001) was found between the accuracy of the conventical and the optimized analysis. The optimized(111)In-DTPA SPECT-CT examination is a powerful diagnostic tool for detecting the cause of ITDD failure.