Accuracy of Vessel-Encoded Pseudocontinuous Arterial Spin-Labeling in Identification of Feeding Arteries in Patients with Intracranial Arteriovenous Malformations

被引:15
|
作者
Yu, S. L. [1 ]
Wang, R.
Wang, R.
Wang, S. [1 ]
Yao, Y. Q. [3 ]
Zhang, D. [1 ]
Zhao, Y. L. [1 ]
Zuo, Z. T. [2 ]
Xue, R. [2 ,5 ,6 ]
Wang, D. J. J. [4 ,5 ,6 ]
Zhao, J. Z. [1 ]
机构
[1] Capital Med Univ, Beijing Tiantan Hosp, Dept Neurosurg, Beijing, Peoples R China
[2] Chinese Acad Sci, Inst Biophys, State Key Lab Brain & Cognit Sci, Beijing MRI Ctr Brain Res, Beijing 100080, Peoples R China
[3] Peking Univ, Dept Neurosurg, Beijing Jishuitan Hosp, Beijing 100871, Peoples R China
[4] Univ Calif Los Angeles, Dept Neurol, Los Angeles, CA 90024 USA
[5] Univ Calif Los Angeles, Beijing Joint Ctr Adv Brain Imaging, Los Angeles, CA USA
[6] Univ Calif Los Angeles, Beijing Joint Ctr Adv Brain Imaging, Beijing, Peoples R China
基金
美国国家卫生研究院;
关键词
QUANTITATIVE ASSESSMENT; ANGIOGRAPHY; BRAIN; RISK;
D O I
10.3174/ajnr.A3638
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Identifying feeding arteries of intracranial AVMs is very important for preoperative evaluation. DSA remains the reference standard for diagnosis but is invasive. Our aim was to evaluate the diagnostic accuracy of vessel-encoded pseudocontinuous arterial spin-labeling in identifying feeding arteries of intracranial AVMs by using DSA as the criterion standard. MATERIALS AND METHODS: Eighteen patients with AVMs were examined with vessel-encoded pseudocontinuous arterial spin-labeling and DSA. Three postlabeling delays (postlabeling delay = 1, 1.3, and 1.6 seconds) were applied in 6 patients, and a single postlabeling delay (1 second) was applied in the remainder. Perfusion-weighted images were decoded into individual vascular territories with standard and relative tagging efficiencies, respectively. The supply fraction of each feeding artery to the AVM was calculated. The within-subject ANOVA was applied to compare supply fractions acquired across 3 postlabeling delays. Receiver operating characteristic analysis curves were calculated to evaluate the diagnostic accuracy of vessel-encoded pseudocontinuous arterial spin-labeling for identifying the feeding arteries of AVMs. RESULTS: There were no significant differences in supply fractions of the 3 major arteries to AVMs acquired with 3 postlabeling delays (P > .05). For vessel-encoded pseudocontinuous arterial spin-labeling with standard labeling efficiencies, the area under the receiver operating characteristic analysis curve was 0.942. The optimal cutoff of the supply fraction for identifying feeding arteries was 15.17%, and the resulting sensitivity and specificity were 84.62% and 93.33%, respectively. For vessel-encoded pseudocontinuous arterial spin-labeling with relative labeling efficiencies, the area under the receiver operating characteristic analysis curve was 0.957. The optimal cutoff of the supply fraction was 11.73%, which yielded an 89.74% sensitivity and 93.33% specificity. CONCLUSIONS: The contribution fraction of each feeding artery of the AVM can be reliably estimated by using vessel-encoded pseudocontinuous arterial spin-labeling. Vessel-encoded pseudocontinuous arterial spin-labeling with either standard or relative labeling efficiencies offers a high level of diagnostic accuracy compared with DSA for identifying feeding arteries.
引用
收藏
页码:65 / 71
页数:7
相关论文
共 46 条
  • [41] Evaluation of Intracranial Arteriovenous Malformations With Four-Dimensional Arterial-Spin Labeling Based 3-T Magnetic Resonance Angiography
    Iryo, Yasuhiko
    Hirai, Toshinori
    Nakamura, Masanobu
    Kawano, Takayuki
    Kaku, Yasuyuki
    Ohmori, Yuki
    Kai, Yutaka
    Azuma, Minako
    Nishimura, Shinichiro
    Shigematsu, Yoshinori
    Kitajima, Mika
    Yamashita, Yasuyuki
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2016, 40 (02) : 290 - 296
  • [42] RETRACTED: Vessel-Encoded Dynamic Magnetic Resonance Angiography Using Arterial Spin Labeling (Retracted article. See vol. 65, pg. 900, 2011)
    Okell, Thomas W.
    Chappell, Michael A.
    Woolrich, Mark W.
    Guenther, Matthias
    Feinberg, David A.
    Jezzard, Peter
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (03) : 698 - 706
  • [43] Are Dynamic Arterial Spin-Labeling MRA and Time-Resolved Contrast-Enhanced MRA Suited for Confirmation of Obliteration following Gamma Knife Radiosurgery of Brain Arteriovenous Malformations?
    Rojas-Villabona, A.
    Pizzini, F. B.
    Solbach, T.
    Sokolska, M.
    Ricciardi, G.
    Lemonis, C.
    DeVita, E.
    Suzuki, Y.
    van Osch, M. J. P.
    Foroni, R., I
    Longhi, M.
    Montemezzi, S.
    Atkinson, D.
    Kitchen, N.
    Nicolato, A.
    Golay, X.
    Jaeger, H. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (04) : 671 - 678
  • [44] Diagnostic Accuracy of Screening Arterial Spin-Labeling MRI Using Hadamard Encoding for the Detection of Reduced CBF in Adult Patients with Ischemic Moyamoya Disease
    Setta, K.
    Matsuda, T.
    Sasaki, M.
    Chiba, T.
    Fujiwara, S.
    Kobayashi, M.
    Yoshida, K.
    Kubo, Y.
    Suzuki, M.
    Yoshioka, K.
    Ogasawara, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2021, 42 (08) : 1403 - 1409
  • [45] Validation of Planning-Free Vessel-Encoded Pseudo-Continuous Arterial Spin Labeling MR Imaging as Territorial-ASL Strategy by Comparison to Super-Selective p-CASL MRI
    Hartkamp, Nolan S.
    Helle, Michael
    Chappell, Michael A.
    Okell, Thomas W.
    Hendrikse, Jeroen
    Bokkers, Reinoud P. H.
    van Osch, Matthias J. P.
    MAGNETIC RESONANCE IN MEDICINE, 2014, 71 (06) : 2059 - 2070
  • [46] Vessel-selective, non-contrast enhanced, time-resolved MR angiography with vessel-selective arterial spin labeling technique (CINEMA-SELECT) in intracranial arteries
    Nakamura M.
    Yoneyama M.
    Tabuchi T.
    Takemura A.
    Obara M.
    Tatsuno S.
    Sawano S.
    Radiological Physics and Technology, 2013, 6 (2) : 327 - 334