Translumbar placement of paired hemodialysis catheters (tesio catheters) and follow-up in 10 patients

被引:30
|
作者
Biswal, R [1 ]
Nosher, JL [1 ]
Siegel, RL [1 ]
Bodner, LJ [1 ]
机构
[1] Univ Med & Dent New Jersey, Robert Wood Johnson Med Sch, Dept Radiol, New Brunswick, NJ 08903 USA
关键词
translumbar; tesio; hemodialysis access; hemodialysis catheters; vascular access;
D O I
10.1007/s002709910015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
For lack of other suitable access, 10 consecutive patients received paired hemodialysis catheters for long-term hemodialysis using a translumbar approach to the inferior vena cava (IVC). All attempts were successful. Five paired catheters were placed using the single-puncture technique, and five using the dual-puncture technique. Catheters were in place for a total of 2252 catheter days. The average duration of catheter placement was 250 days (range 30-580 days). All catheters were functioning up to the time the study was completed or the patient died. The most common complication was partial dislodgment of the catheter in 3 of 23 catheters (13%), all occurring in obese patients. One episode of retroperitoneal hemorrhage was noted in a patient having the single-access technique. There were no episodes of infection or IVC thrombosis.
引用
收藏
页码:75 / 78
页数:4
相关论文
共 50 条
  • [31] Spurious hyperphosphatemia in patients on hemodialysis with catheters
    Schiller, Brigitte
    Virk, Bhupinder
    Blair, Martin
    Wong, Amy
    Moran, John
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2008, 52 (03) : 617 - 620
  • [32] Safety Aspects in Patients on Hemodialysis with Catheters
    Polakovic, Vladimir
    Lopot, Frantisek
    PATIENT SAFETY IN DIALYSIS ACCESS, 2015, 184 : 189 - 204
  • [33] Central Vascular Access By Tesio Catheters (tc) For Chronic Hemodialysis In Neonates And Infants: Beyond The Rules
    Graziano, Ugo
    Severino, Giovanni
    Cardone, Massimino
    Musumeci, Antonino
    Pecoraro, Carmine
    PEDIATRIC NEPHROLOGY, 2014, 29 (09) : 1760 - 1760
  • [34] Comparison Between the Fixation of Peritoneal Dialysis Catheters to the Peritoneal Wall and the Conventional Placement Technique: Clinical Experience and Follow-Up of a New Implant Technique for Peritoneal Dialysis Catheters
    Io, Hiroaki
    Maeda, Kunimi
    Sekiguchi, Yoshimi
    Shimaoka, Tetsutaro
    Aruga, Seiki
    Nakata, Junichiro
    Nakamoto, Hirotaka
    Hotta, Yoko
    Koyanagi, Ichiro
    Inaba, Masanori
    Kanda, Reo
    Nakano, Takanori
    Wakabayashi, Keiichi
    Sasaki, Yuu
    Inuma, Jiro
    Kaneko, Kayo
    Hamada, Chieko
    Fukui, Mitsumine
    Tomino, Yasuhiko
    SEMINARS IN DIALYSIS, 2014, 27 (04) : E42 - E47
  • [35] Conversion of temporary hemodialysis catheters to permanent hemodialysis catheters: A retrospective study of catheter exchange versus classic de novo placement
    Falk, A
    Prabhuram, N
    Parthasarathy, S
    SEMINARS IN DIALYSIS, 2005, 18 (05) : 425 - 430
  • [36] Re: A randomized, prospective comparison of the tesio, ash split, and opti-flow hemodialysis catheters - Response
    Richard, HM
    Stainken, B
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2002, 13 (03) : 342 - 343
  • [37] Placement, performance and complications of Tessio Twin tunnelles catheters for hemodialysis
    Ibrik, O.
    Samon, R.
    Roca, R.
    Viladoms, J.
    Mora, J.
    NEFROLOGIA, 2006, 26 (06): : 719 - 725
  • [38] Radiologic placement of hemodialysis central venous catheters: a practical guide
    Schemmer, D
    Sadler, DJ
    Gray, RR
    Saliken, JC
    So, CB
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2001, 52 (02): : 103 - 111
  • [39] Use of the brachiocephalic vein for placement of tunneled hemodialysis catheters.
    Falk, A
    Vassalotti, J
    Teodorescu, V
    Uribarri, J
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2002, 13 : 229A - 229A
  • [40] Deviations of placement/function of permanent central vein catheters for hemodialysis
    Skandalos, I
    Hatzibaloglou, A
    Evagelou, I
    Ntitsias, T
    Samaras, A
    Visvardis, G
    Mavromatidis, K
    Karamoshos, K
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2005, 28 (06): : 583 - 590