Effect of 2 Impression Techniques on the Dimensional Accuracy of Working Implant Prosthesis Models: An In Vitro Study

被引:7
|
作者
Calesini, Gaetano
Zarone, Fernando [1 ]
Sorrentino, Roberto [1 ]
Micarelli, Costanza
Fabianelli, Andrea [2 ,3 ]
Papacchini, Federica
Gherlone, Enrico [4 ]
机构
[1] Univ Naples Federico II, Naples, Italy
[2] Univ Sheffield, Sheffield, S Yorkshire, England
[3] Univ Brescia, Brescia, Italy
[4] San Raffaele Univ, Milan, Italy
关键词
Implant prosthesis; impression technique; precision; interceptive impression; internal connection; PROSTHODONTICS; FIT; SELECTION;
D O I
10.1097/SCS.0000000000000715
中图分类号
R61 [外科手术学];
学科分类号
摘要
Purpose: Implant impressions and working models form integrated precision systems for registration and transmission of clinical data. The components of implant systems have a dimensional tolerance capable of introducing inaccuracies in the impression, thus in the prosthetic framework. This article aimed at comparing 2 repositioning impression techniques: one using impression copings (conventional technique) and the other using the final abutments as impression copings (interceptive technique). Materials and Methods: Two experimental models, one with 4 parallel implants and the other with 4 nonparallel implants, were used to make silicone impressions. Twenty impressions were made with the conventional technique, and a further 20 were made with the interceptive technique. Three-dimensional images acquired with a three-dimensional scanner were measured using a three-dimensional image analysis software, comparing models obtained from the impressions with the experimental models. Data were statistically analyzed by means of confidence intervals calculated with the mean (alpha = 0.05), descriptive (box plot), and bivariate analyses. Results: Statistic analysis highlighted significant differences among models obtained using both techniques: the interceptive technique generated working models with less distortion and variability. Conclusions: For internal-connection implants, the interceptive technique provided significantly more precise working models than did the conventional technique.
引用
收藏
页码:822 / 827
页数:6
相关论文
共 50 条
  • [1] The effect of different implant impression splinting techniques and time on the dimensional accuracy: An in vitro study
    Rutkunas, V.
    Bilius, V.
    Simonaitis, T.
    Auskalnis, L.
    Jurgilevicius, J.
    Akulauskas, M.
    JOURNAL OF DENTISTRY, 2022, 126
  • [2] Assessment of Effect of Different Sterilization Agents on Dimensional Accuracy of Different Impression Materials in Implant Prosthesis - An In vitro Study
    Kavita, Kumari
    Reddy, K. R. Parameshwar
    Reddy, K. R. Maheshwar
    Kumar, Swatantra
    Pandey, Gyanendra
    Singh, Revati
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2021, 13 (06): : S1620 - S1623
  • [3] Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: An in vitro study
    Lee, Heeje
    Ercoli, Carlo
    Funkenbusch, Paul D.
    Feng, Changyong
    JOURNAL OF PROSTHETIC DENTISTRY, 2008, 99 (02): : 107 - 113
  • [4] Accuracy of Impression Techniques for an Implant-Supported Prosthesis
    Del'Acqua, Marcelo Antonialli
    Chavez, Alejandro Munoz
    Compagnoni, Marco Antonio
    Mollo, Francisco de Assis, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (04) : 715 - 721
  • [5] Evaluation of the effect of implant angulations and impression techniques on implant cast accuracy u An in vitro study
    Arora, Aman
    Upadhyaya, Viram
    Parashar, Kirti R.
    Malik, Divya
    JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2019, 19 (02): : 149 - 158
  • [6] Accuracy of impression and pouring techniques for an implant-supported prosthesis
    Del'Acqua, Marcelo Antonialli
    Arioli-Filho, Joao Neudenir
    Compagnoni, Marco Antonio
    Mollo, Francisco de Assis, Jr.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2008, 23 (02) : 226 - 236
  • [7] Effect of impression coping and implant angulation on the accuracy of implant impressions: an in vitro study
    Jo, Si-Hoon
    Kim, Kyoung-Ii
    Seo, Jae-Min
    Song, Kwang-Yeob
    Park, Ju-Mi
    Ahn, Seung-Geun
    JOURNAL OF ADVANCED PROSTHODONTICS, 2010, 2 (04): : 128 - 133
  • [8] Accuracy of different impression techniques for multiunit implant restoration: A qualitative in vitro study
    Ismail, Ibrahim Ahmed
    Alhajj, Mohammed Nasser
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : E1 - E5
  • [9] Evaluation of Accuracy of Casts of Multiple Internal Connection Implant Prosthesis Obtained From Different Impression Materials and Techniques: An In Vitro Study
    Pujari, Malesh
    Garg, Pooja
    Prithviraj, D. R.
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (02) : 137 - 145
  • [10] Effect of Splinting in Accuracy of Two Implant Impression Techniques
    de Avila, Erica Dorigatti
    Moraes, Fernanda de Matos
    Castanharo, Sabrina Maria
    Del'Acqua, Marcelo Antonialli
    Mollo, Francisco de Assis, Jr.
    JOURNAL OF ORAL IMPLANTOLOGY, 2014, 40 (06) : 633 - 639