Continuous non-invasive end-tidal CO2 monitoring in pediatric inpatients with diabetic ketoacidosis

被引:23
|
作者
Agus, Michael S. D.
Alexander, Jamin L.
Mantell, Patricia A.
机构
[1] Harvard Univ, Sch Med, Childrens Hosp Boston, Dept Med,Div Endocrinol, Boston, MA 02115 USA
[2] Childrens Hosp, Dept Nursing, Boston, MA 02115 USA
关键词
capnography; diabetic ketoacidosis; human; metabolic acidosis; physiologic monitoring;
D O I
10.1111/j.1399-5448.2006.00186.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Pediatric inpatients with diabetic ketoacidosis (DKA) are routinely subjected to frequent blood draws in order to closely monitor degree of acidosis and response to therapy. The typical level of acidosis monitoring is less than ideal, however, because of the high cost and invasiveness of frequent blood labs. Previous studies have validated end-tidal carbon dioxide (EtCO2) monitoring in the emergency department (ED) for varying periods of time. We extend these findings to the inpatient portion of the hospitalization during which the majority of blood tests are sent. Methods: All patients admitted to an intermediate care unit in (InCU) a large children's hospital were fitted with an appropriately sized oral/nasal cannula capable of sensing EtCO2. Laboratory studies were obtained according to hospital clinical practice guidelines. In a retrospective analysis, EtCO2 values were correlated with serum total CO2 (stCO(2)), venous pH (vpH), venous pCO(2) (vpCO(2)), and calculated bicarbonate from venous blood gas (vHCO(3)(-)). Results: A total of 78 consecutive episodes of DKA in 72 patients aged 1-21 yr were monitored for 3-38 h with both capnography and laboratory testing, producing 334 comparisons. Initial values were as follows, reported as median (range): stCO(2), 11 (4-22) mmol/L; vpH, 7.281 (6.998-7.441); vpCO(2), 28.85 (9.3-43.3) mmHg; and vHCO(3)(-), 14 (3-25) mmol/L. EtCO2 was correlated well with stCO(2) (r = 0.84, p < 0.001), vHCO(3)(-) (r = 0.84, p < 0.001), and vpCO(2) (r = 0.79, p < 0.001). Conclusions: These data support the findings of previous studies limited to ED populations and suggest that non-invasive EtCO2 monitoring is a valuable and reliable tool to continuously follow acidosis in the setting of the acutely ill pediatric patient with DKA. Continuous EtCO2 monitoring offers the practitioner an early warning system for unexpected changes in acidosis that augments the utility of intermittent blood gas determinations.
引用
收藏
页码:196 / 200
页数:5
相关论文
共 50 条
  • [21] NONINVASIVE MONITORING OF END-TIDAL CO2 IN SPONTANEOUSLY BREATHING CHILDREN
    FLANAGAN, J
    WHEELER, T
    BURNEY, C
    TOBIAS, JD
    ANESTHESIOLOGY, 1993, 79 (3A) : A1159 - A1159
  • [22] End-tidal CO2 after CO2 embolism
    Jose Eduardo Tanus-Santos
    Canadian Journal of Anaesthesia, 1998, 45 : 913 - 914
  • [23] End-tidal CO2 after CO2 embolism
    Tanus-Santos, JE
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (09): : 913 - 914
  • [24] Abnormal end-tidal CO2 waveforms
    Jonathan L. Benumof
    Canadian Journal of Anaesthesia, 2003, 50
  • [25] Abnormal end-tidal CO2 waveforms
    Benumof, JL
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2003, 50 (07): : 754 - 754
  • [26] Misleading end-tidal CO2 tensions
    Kerry Brandis
    Canadian Journal of Anaesthesia, 1999, 46 : 998 - 998
  • [27] Misleading end-tidal CO2 tensions
    Brandis, K
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1999, 46 (10): : 998 - 998
  • [28] THE FEF END-TIDAL CO2 DETECTOR
    WEE, MYK
    ANAESTHESIA, 1990, 45 (03) : 251 - 251
  • [29] Misleading end-tidal CO2 tensions
    Wahba, RWM
    Tessler, MJ
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1996, 43 (08): : 862 - 866
  • [30] Unknown use of end-tidal CO2 in metabolic emergencies in pediatric patients
    Redant, Sebastien
    Angoulvant, Francois
    Honore, Patrick M.
    Attou, Rachid
    Biarent, Dominique
    De Bels, David
    JOURNAL OF TRANSLATIONAL INTERNAL MEDICINE, 2019, 7 (02) : 76 - 78