Biosensor based on coupled enzyme reactions for determination of arginase activity

被引:1
|
作者
Urbanowicz, Marcin [1 ]
Sadowska, Kamila [1 ]
Paziewska-Nowak, Agnieszka [1 ]
Ldatowska, Anna So [1 ]
Nalecz, Dorota G. Pijanowska [1 ]
机构
[1] Polish Acad Sci, Inst Biocybernet & Biomed Engn, Ks Trojdena 4, PL-02109 Warsaw, Poland
关键词
Potentiometric biosensor; Arginase activity; Coupled enzyme reactions; Immobilized enzyme; ARGININE; ELECTRODE; ASSAY; INSIGHTS; UREASE;
D O I
10.1016/j.bioelechem.2022.108137
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The determination of the enzymatic activity requires constant and reproducible measuring conditions, therefore highly stable potentiometric biosensor operating on the basis of coupled enzyme reactions is proposed for arginase activity determination. Glassy carbon electrode was covered with polyazulene ion-to-electron transducing layer, which ensured improved stability of the prepared sensor. The sensor's selectivity was obtained by applying NH4+-selective membrane on the transducing layer, which was further biofunctionalized with urease via covalent immobilization. The immobilized urease served as an auxiliary enzyme in the arginase-urease coupled enzyme assay. Thanks to obtained high stability (low drift coefficient ~0.9 mV/h) and short response time (36 s), the developed urea biosensor enabled continuous monitoring the coupled enzyme reactions indirectly, through measurement the ammonium ion concentration. Arginase activity and Michaelis-Menten constant for arginine-arginase pair under defined experimental conditions, in particular constant concentration of manganese ions, was determined. Mathematical description of the coupled enzyme reactions kinetics is discussed and used to analyse the reactions with auxiliary enzyme immobilized on the electrode surface. The proposed method of determining arginase activity with use of highly stable potentiometric urease-based biosensor, allows obtaining results in the units of absolute arginase activity.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] A COLORIMETRIC METHOD FOR DETERMINATION OF SERUM ARGINASE ACTIVITY
    LOEB, WF
    STUHLMAN, RA
    CLINICAL CHEMISTRY, 1969, 15 (02) : 162 - +
  • [32] COLORIMETRIC METHOD FOR RAPID DETERMINATION OF ARGINASE ACTIVITY
    GILBOE, DD
    WILLIAMS, JN
    PROCEEDINGS OF THE SOCIETY FOR EXPERIMENTAL BIOLOGY AND MEDICINE, 1956, 91 (04): : 537 - 539
  • [33] STUDIES IN PRAWNS .4. DETERMINATION OF ARGININE BY ENZYME ARGINASE
    APPANNA, TC
    JOURNAL OF NUTRITION AND DIETETICS, 1969, 6 (02): : 82 - &
  • [34] DETERMINATION OF MYROSINASE (THIOGLUCOSIDE GLUCOHYDROLASE) ACTIVITY BY A SPECTROPHOTOMETRIC COUPLED ENZYME ASSAY
    WILKINSON, AP
    RHODES, MJC
    FENWICK, GR
    ANALYTICAL BIOCHEMISTRY, 1984, 139 (02) : 284 - 291
  • [35] A Novel Biosensor Based on Glucose Oxidase for Activity Determination of α - Amylase
    Altug, Cagri
    Mengulluoglu, Umut
    Kurt, Elif
    Kaya, Secil
    Dinckaya, Erhan
    ARTIFICIAL CELLS BLOOD SUBSTITUTES AND BIOTECHNOLOGY, 2011, 39 (05): : 298 - 303
  • [36] A New Amperometric Enzyme-based Biosensor for Specific Determination of 17β-estradiol
    Spychalska, K.
    Cabaj, J.
    SENSORS AND ELECTRONIC INSTRUMENTATION ADVANCES (SEIA' 19), 2019, : 280 - 281
  • [37] Graphene Quantum Dots and Enzyme-Coupled Biosensor for Highly Sensitive Determination of Hydrogen Peroxide and Glucose
    Wang, Bingdi
    Shen, Jing
    Huang, Yanjun
    Liu, Zhenning
    Zhuang, Hong
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2018, 19 (06):
  • [38] Coupled Enzyme Reactions in Multicompartment Microparticles
    Baeumler, Hans
    Georgieva, Radostina
    BIOMACROMOLECULES, 2010, 11 (06) : 1480 - 1487
  • [39] KINETICS OF COUPLED ENZYME-REACTIONS
    YANG, SY
    SCHULZ, H
    BIOCHEMISTRY, 1987, 26 (17) : 5579 - 5584
  • [40] COUPLED REACTIONS FOR DETERMINATION OF ENZYMES AND METABOLITES BASED ON THE USE OF LUMINESCENCE
    RODA, A
    GIROTTI, S
    GHINI, S
    ANGELLOTTI, A
    PISTILLO, A
    JOURNAL OF BIOLUMINESCENCE AND CHEMILUMINESCENCE, 1988, 2 (04): : 250 - 250