Power System Dynamic State Estimation With Synchronized Phasor Measurements

被引:94
|
作者
Aminifar, Farrokh [1 ]
Shahidehpour, Mohammad [2 ]
Fotuhi-Firuzabad, Mahmud [3 ]
Kamalinia, Saeed [4 ]
机构
[1] Univ Tehran, Sch Elect & Comp Engn, Coll Engn, Tehran 14174, Iran
[2] IIT, Galvin Ctr Elect Innovat, Chicago, IL 60616 USA
[3] Sharif Univ Technol, Ctr Excellence Power Syst Control & Management, Dept Elect Engn, Tehran 145888, Iran
[4] S&C Elect Co, Power Syst Solut Div, Chicago, IL 60626 USA
关键词
Dynamic state estimation; mathematical programming; power system monitoring; state prediction; synchrophasor measurement; uncertainty propagation; ALGORITHM; IMPACT;
D O I
10.1109/TIM.2013.2278595
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The dynamic state estimation (DSE) applied to power systems with synchrophasor measurements would estimate the system's true state based on measurements and predictions. In this application, as phasor measurement units (PMUs) are not deployed at all power system buses, state predictions would enhance the redundancy of DSE input data. The significance of predicted and measured data in DSE is affected by their confidence levels, which are inversely proportional to the corresponding variances. In practice, power system states may undergo drastic changes during hourly load fluctuations, component outages, or network switchings. In such conditions, the inclusion of predicted values could degrade the power system state estimation. This paper presents a mixed-integer programming formulation of DSE that is capable of simultaneously discarding predicted values whenever sudden changes in the system state are detected. This feature enhances the DSE computation and will not require iterative executions. The proposed model accommodates system-wide synchronized measurements of PMUs, which could be of interest to smart grid applications in energy management systems. The voltage phasors at buses without PMUs are calculated via voltage and current measurements of adjacent buses, which are referred to as indirect measurements. The guide to the expression of uncertainty in measurement is used for computing the confidence level of indirect measurements based on uncertainties associated with PMU measurements as well as with transmission line parameters. Simulation studies are conducted on an illustrative three-bus example and the IEEE 57-bus power system, and the performance of the proposed model is thoroughly discussed.
引用
收藏
页码:352 / 363
页数:12
相关论文
共 50 条
  • [21] Influence of Phasor Measurement Unit in Power System Dynamic State Estimation
    Dowi, Sideig A.
    Li, Gengyin
    2013 2ND INTERNATIONAL SYMPOSIUM ON INSTRUMENTATION AND MEASUREMENT, SENSOR NETWORK AND AUTOMATION (IMSNA), 2013, : 395 - 399
  • [22] Estimation of radial power system transfer path dynamic parameters using synchronized phasor data
    Chow, Joe H.
    Chakrabortty, Aranya
    Vanfretti, Luigi
    Arcak, Murat
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2008, 23 (02) : 564 - 571
  • [23] Dynamic equivalent state estimation for multi-area power systems with synchronized phasor measurement units
    Vahidnia, Arash
    Ledwich, Gerard
    Palmer, Edward
    Ghosh, Arindam
    ELECTRIC POWER SYSTEMS RESEARCH, 2013, 96 : 170 - 176
  • [24] State estimation of flexible AC transmission systems considering synchronized phasor measurements
    Zamora-Cardenas, E. A.
    Alcaide-Moreno, B. A.
    Fuerte-Esquivel, C. R.
    ELECTRIC POWER SYSTEMS RESEARCH, 2014, 106 : 120 - 133
  • [25] Analysis of power system dynamics based on multiple synchronized phasor measurements
    Hashiguchi, T
    Yoshimoto, M
    Mitani, Y
    Saeki, O
    Tsuji, K
    Hojo, M
    Ukai, H
    2003 IEEE POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-4, CONFERENCE PROCEEDINGS, 2003, : 615 - 620
  • [26] State Reconstruction from Synchronized Phasor Measurements
    Glavic, Mevludin
    Van Cutsem, Thierry
    2011 2ND IEEE PES INTERNATIONAL CONFERENCE AND EXHIBITION ON INNOVATIVE SMART GRID TECHNOLOGIES (ISGT EUROPE), 2011,
  • [27] The Advancing Assessment of Power System Stability Using Synchronized Phasor Measurements
    Bektimirov, A.T.
    Tokhtibakiyev, K.K.
    Merekenov, M.A.
    Mikhalkova, E.G.
    Saukhimov, A.A.
    Nurgaliyeva, S.A.
    Journal of Engineering Science and Technology Review, 2020, (Special Issue) : 238 - 241
  • [28] The Advancing Assessment of Power System Stability Using Synchronized Phasor Measurements
    Bektimirov, A.T.
    Tokhtibakiyev, K.K.
    Merekenov, M.A.
    Mikhalkova, E.G.
    Saukhimov, A.A.
    Nurgaliyeva, S.A.
    Journal of Engineering Science and Technology Review, 2019, (Special Issue) : 238 - 241
  • [29] Dynamic State Estimation of Full Power Plant Model From Terminal Phasor Measurements
    Paul, Avishek
    Joos, Geza
    Kamwa, Innocent
    2018 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION (T&D), 2018,
  • [30] Dynamic State Estimator with Phasor Measurements for Power System Electromechanical Transient Process
    Bi, Tianshu
    Qin, Xiaohui
    Yang, Qixun
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 1412 - 1416