Diffusion Tensor Imaging and Fiber Tractography of Skeletal Muscle: Optimization of b Value for Imaging at 1.5 T

被引:30
|
作者
Saupe, Nadja [1 ,2 ]
White, Lawrence M. [1 ,2 ]
Stainsby, Jeffrey [1 ,2 ]
Tomlinson, George [1 ,2 ]
Sussman, Marshall S. [1 ,2 ]
机构
[1] Univ Toronto, Mt Sinai Hosp, Dept Med Imaging, Toronto, ON M5G 1X5, Canada
[2] Univ Toronto, Univ Hlth Network, Toronto, ON M5G 1X5, Canada
关键词
b value; calf; diffusion tensor MRI; fiber tractography; WHITE-MATTER; HUMAN CALF; MRI; BRAIN; ARCHITECTURE; SENSITIVITY; VALIDATION; SENSE;
D O I
10.2214/AJR.08.1340
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The aim of our study was to determine the optimal b value for 1.5-T diffusion tensor (DT) MRI and fiber tractography of in vivo human skeletal muscle. SUBJECTS AND METHODS. Five healthy volunteers were included in this prospective study. DT MRI of the proximal calf was performed with 15 directions of diffusion sensitization and parallel imaging with an acceleration factor of 2. Each single-shot spin-echo echo-planar imaging sequence was performed in each volunteer with eight b values ranging from 125 s/mm(2) to 1,000 s/mm(2). Fiber tractography of two calf muscles (anterior tibialis and lateral gastrocnemius) was performed, and image quality was ranked 1-8. Fractional anisotropy, signal-to-noise ratio, and fiber density index were assessed for both muscles at each b value. Statistical analysis was performed with repeated measurement analysis of variance. RESULTS. Among all fiber tractographic images assessed, those obtained at a b value of 625 s/mm(2) were qualitatively ranked first (best image quality) or second (second-best image quality). Signal-to-noise ratio was highest for both muscles at a b value of 125 s/mm(2) (anterior tibialis, 66.2; lateral gastrocnemius, 60.1). The highest fiber density indexes were found for both muscles at a b value of 625 s/mm(2) (anterior tibialis index, 7.82; lateral gastrocnemius index, 5.75). In the analysis of variance no significant differences were found between fractional anisotropy and b values for either muscle (p = 0.359 and p = 0.078). CONCLUSION. The optimal b value for in vivo DT MRI and tractographic assessment of human skeletal muscle in the calf at 1.5 T MRI was found to be 625 s/mm(2).
引用
收藏
页码:W282 / W290
页数:9
相关论文
共 50 条
  • [21] Diffusion tensor imaging and fiber tractography in Parry-Romberg syndrome
    Moon, W. J.
    Kim, H. J.
    Roh, H. G.
    Oh, J.
    Han, S. H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2008, 29 (04) : 714 - 715
  • [22] Diffusion tensor imaging and fiber tractography for the visualization of the female pelvic floor
    Zijta, Frank M.
    Froeling, Martijn
    Nederveen, Aart J.
    Stoker, Jaap
    CLINICAL ANATOMY, 2013, 26 (01) : 110 - 114
  • [23] Value of diffusion tensor imaging and tractography in unilateral lumbar disc prolapse
    Ahmed Sayed Abd El Basset
    Ahmed Hesham Mohamed Saeed
    Mona Hussein Tawfik
    Marwa Shehata Abd El Hady
    Egyptian Journal of Radiology and Nuclear Medicine, 52
  • [24] Value of diffusion tensor imaging and tractography in unilateral lumbar disc prolapse
    El Basset, Ahmed Sayed Abd
    Saeed, Ahmed Hesham Mohamed
    Tawfik, Mona Hussein
    El Hady, Marwa Shehata Abd
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2021, 52 (01):
  • [25] Clinical applications of skeletal muscle diffusion tensor imaging
    Martin-Noguerol, Teodoro
    Barousse, Rafael
    Wessell, Daniel E.
    Rossi, Ignacio
    Luna, Antonio
    SKELETAL RADIOLOGY, 2023, 52 (09) : 1639 - 1649
  • [26] Clinical applications of skeletal muscle diffusion tensor imaging
    Teodoro Martín-Noguerol
    Rafael Barousse
    Daniel E. Wessell
    Ignacio Rossi
    Antonio Luna
    Skeletal Radiology, 2023, 52 : 1639 - 1649
  • [27] In vivo visualization of the levator ani muscle subdivisions using MR fiber tractography with diffusion tensor imaging
    Rousset, Pascal
    Delmas, Vincent
    Buy, Jean-Noel
    Rahmouni, Alain
    Vadrot, Dominique
    Deux, Jean-Francois
    JOURNAL OF ANATOMY, 2012, 221 (03) : 221 - 228
  • [28] In vivo evaluation of the levator ani muscle in primiparous women using diffusion tensor imaging and fiber tractography
    Cui, Can
    Zhao, Yujiao
    Cui, Dawei
    Li, Na
    Pan, Jiangfeng
    Shen, Wen
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2022, 157 (03) : 663 - 670
  • [29] Fiber Dissection and Diffusion Tensor Imaging Tractography Study of the Temporoparietal Fiber Intersection Area
    Martino, Juan
    da Silva-Freitas, Rousinelle
    Caballero, Hugo
    Marco de Lucas, Enrique
    Garcia-Porrero, Juan A.
    Vazquez-Barquero, Alfonso
    NEUROSURGERY, 2013, 72 : 87 - 97
  • [30] Diffusion tensor imaging and tractography of distal peripheral nerves at 3 T
    Hiltunen, J
    Suortti, T
    Arvela, S
    Seppä, M
    Joensuu, R
    Hari, R
    CLINICAL NEUROPHYSIOLOGY, 2005, 116 (10) : 2315 - 2323