Focused Beam Reflectance Measurement for Monitoring the Extent and Efficiency of Flocculation in Mineral Systems

被引:46
|
作者
Senaputra, Alexander [1 ]
Jones, Franca [1 ]
Fawell, Phillip D. [2 ]
Smith, Peter G. [2 ]
机构
[1] Curtin Univ, Dept Chem, Perth, WA 6845, Australia
[2] CSIRO Proc Sci & Engn, Waterford, WA 6152, Australia
关键词
flocculant; flocculation; aggregate size; focused beam reflectance measurement; fines capture; TURBULENT PIPE-FLOW; PARTICLE-SIZE; POLYMER FLOCCULATION; SHEAR-FLOCCULATION; MEASUREMENT PROBE; AGGREGATE SIZE; SUSPENSION; CALCITE; BREAKAGE; DYNAMICS;
D O I
10.1002/aic.14256
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Focused beam reflectance measurement (FBRM), where a scanning laser focused through a sapphire window measures real-time reflected chord distributions without solids dilution, is attractive for characterizing flocculation performance. An enhanced measurement principle in new FBRM instruments has implications for flocculation studies, demonstrated using hematite in synthetic Bayer liquor. Comparisons of previous (M500) and new (G400) instruments were complicated by the impact of their different physical dimensions upon flocculation hydrodynamics, but the G400 clearly measured larger chords. The original measurement principle based on a reflected intensity threshold counts large low-density aggregates as multiple chords; in contrast, the change to edge detection (very low threshold) is more likely to see a single chord, an advantage for studying mineral systems (aggregates often >500 mu m). The G400 also captures bimodal character in unweighted chord distributions, producing distinct peaks for aggregates and fines after suboptimal flocculation; such peaks are rarely well resolved in older FBRM. (c) 2013 American Institute of Chemical Engineers AIChE J, 60: 251-265, 2014
引用
收藏
页码:251 / 265
页数:15
相关论文
共 50 条
  • [21] The use of focused beam reflectance measurement in the development of a new nanosize particle
    Gerli, A
    Keiser, BA
    Surya, PI
    APPITA JOURNAL, 2001, 54 (01): : 36 - 40
  • [22] Effective sapphire repellency treatment to reduce fouling of a focused beam reflectance measurement (FBRM) probe in bituminous systems
    Saraka, Colin
    Machado, Marcio B.
    Webster, Scott E.
    Gomez, Clara
    Kresta, Suzanne M.
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2019, 97 (06): : 1949 - 1952
  • [23] Study of phosphoric acid crystallization using a focused beam reflectance measurement method
    Ma, Yong
    Chen, Kui
    Wu, Yanyang
    Zhu, Jiawen
    Sheng, Yong
    CRYSTAL RESEARCH AND TECHNOLOGY, 2010, 45 (10) : 1012 - 1016
  • [24] Interpretation of focused beam reflectance measurement (FBRM) data via simulated crystallization
    Yu, Zai Qun
    Chow, Pui Shan
    Tan, Reginald B. H.
    ORGANIC PROCESS RESEARCH & DEVELOPMENT, 2008, 12 (04) : 646 - 654
  • [25] Characterization of milk protein concentrate solubility using focused beam reflectance measurement
    Fang, Yuan
    Selomulya, Cordelia
    Chen, Xiao Dong
    DAIRY SCIENCE & TECHNOLOGY, 2010, 90 (2-3) : 253 - 270
  • [26] Predicting physical properties of pharmaceutical compacts using focused beam reflectance measurement (FBRM)
    Alshihabi, F.
    Vandamme, T.
    Betz, G.
    JOURNAL OF DRUG DELIVERY SCIENCE AND TECHNOLOGY, 2012, 22 (06) : 522 - 530
  • [27] Measuring the particle size of a known distribution using the focused beam reflectance measurement technique
    Greaves, David
    Boxall, John
    Mulligan, James
    Montesi, Alberto
    Creek, Jefferson
    Sloan, E. Dendy
    Koh, Carolyn A.
    CHEMICAL ENGINEERING SCIENCE, 2008, 63 (22) : 5410 - 5419
  • [28] Modeling focused beam reflectance measurement and its application to sizing of particles of variable shape
    Vaccaro, Andrea
    Sefcik, Jan
    Morbidelli, Massimo
    PARTICLE & PARTICLE SYSTEMS CHARACTERIZATION, 2007, 23 (05) : 360 - 373
  • [29] Comparison of morphological characteristics of Streptomyces natalensis by image analysis and focused beam reflectance measurement
    Pearson, AP
    Glennon, B
    Kieran, PM
    BIOTECHNOLOGY PROGRESS, 2003, 19 (04) : 1342 - 1347
  • [30] Optimization of Crystallization of Ergotamine Tartrate Using Focused Beam Reflectance Measurement Laser Probe
    Gabriel, Roman
    Jegorov, Alexandr
    Safarova, Klara
    CHEMICKE LISTY, 2012, 106 (08): : 765 - 768