Analytical reconstruction for helical cone-beam SPECT with non-uniform attenuation correction

被引:0
|
作者
Huang, Qiu [1 ]
Zeng, Gengsheng L. [1 ]
Gullberg, Grant T. [1 ]
机构
[1] Univ Utah, UCAIR, Dept Radiol, Salt Lake City, UT 84108 USA
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper concerns image reconstruction for helical cone-beam (CB) single photon emission computed tomography (SPECT) with compensation of non-uniform attenuation. We present a filtering-backprojection-filtering algorithm of the FDK type by extending the FBP algorithms for attenuated fan-beam projections to the three-dimensional (3D) cone-beam projections. Each transaxial slice can be reconstructed from attenuated projection data acquired along a specific 2 pi segment of the helix. CB artifacts are less for smaller pitch of the heical trajectory. The algorithm is validated by numerical results for a simulated Shepp-Logan-like phantom and the Defrise phantom.
引用
收藏
页码:1856 / 1859
页数:4
相关论文
共 50 条
  • [31] Evaluation of helical cone-beam CT reconstruction algorithms
    Köhler, T
    Bontus, C
    Brown, K
    Heuscher, D
    Grass, M
    Shechter, G
    Proksa, R
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1217 - 1220
  • [32] An Improved Helical Cone-beam CT Image Reconstruction
    Gao, Yang
    Ma, Jianhua
    Chen, Wufan
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2178 - 2182
  • [33] The frequency split method for helical cone-beam reconstruction
    Shechter, G
    Köhler, T
    Altman, A
    Proksa, R
    MEDICAL PHYSICS, 2004, 31 (08) : 2230 - 2236
  • [34] Analytical reconstruction of 4-D dynamic cardiac SPECT with noise-reduction and non-uniform attenuation compensation
    Fan, Yi
    Lu, Hongbing
    Liang, Zhengrong
    Hao, Chongyang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2): : 195 - 198
  • [35] Non-uniform scatter and attenuation correction for brain spect without transmission imaging.
    Stodilka, RZ
    Kemp, BJ
    Kertesz, A
    Prato, FS
    Kuhl, DC
    Nicholson, RL
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 297P - 297P
  • [36] A comparison of two iterative reconstruction methods with non-uniform attenuation correction.
    Kauppinen, TA
    Alenius, ST
    Koskinen, MO
    Kuikka, JT
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 301P - 301P
  • [37] An analytical simulation technique for cone-beam CT and pinhole SPECT
    Zhang Xuezhu
    Qi Yujin
    NUCLEAR SCIENCE AND TECHNIQUES, 2011, 22 (06) : 338 - 343
  • [38] Non-uniform Z-resolution in cone-beam multi-slice CT
    Heuscher, DJ
    Liang, Y
    Chen, L
    Brown, K
    Utrup, SJ
    Vembar, M
    RADIOLOGY, 2001, 221 : 543 - 543
  • [39] An analytical simulation technique for cone-beam CT and pinhole SPECT
    ZHANG Xuezhu QI Yujin~* Shanghai Institute of Applied Physics
    NuclearScienceandTechniques, 2011, 22 (06) : 338 - 343
  • [40] A CONE-BEAM SPECT RECONSTRUCTION ALGORITHM WITH A DISPLACED CENTER OF ROTATION
    LI, JY
    JASZCZAK, RJ
    WANG, HL
    GULLBERG, GT
    GREER, KL
    COLEMAN, RE
    MEDICAL PHYSICS, 1994, 21 (01) : 145 - 152