A correction procedure for the self-absorption artifacts in x-ray Compton tomography

被引:6
|
作者
Brunetti, A
Golosio, B
Cesareo, R
机构
[1] Univ Sassari, Dipartimento Matemat & Fis, I-07100 Sassari, Italy
[2] Univ Cagliari, Complesso Univ Monserrato, Dipartimento Fis, I-09042 Monserrato, CA, Italy
关键词
D O I
10.1002/xrs.592
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
Compton tomography generally makes use of the same scanning techniques (rotations and translations) as transmission tomography but modifies the reconstruction software. However, it is also possible to use an x-y scanning technique, i.e. two independent sets of linear translations of the source and of the detector. The x-y technique allows one to scan only a limited zone of the sample, whereas the rotation-translations method needs to scan the whole sample. x-y scanning has a serious drawback: it is more sensitive than the translation-rotation technique to self-absorption phenomena in the matrix. In this paper a new algorithm for x-y scanning reconstruction is described. This algorithm considers and corrects self-absorption effects without requiring a priori knowledge about the chemical composition. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:377 / 382
页数:6
相关论文
共 50 条
  • [31] QUANTITATIVE ANALYSIS OF METAL ARTIFACTS IN X-RAY TOMOGRAPHY
    Palacios, Benjamin
    Uhlmann, Gunther
    Wang, Yiran
    SIAM JOURNAL ON MATHEMATICAL ANALYSIS, 2018, 50 (05) : 4914 - 4936
  • [32] Artifacts in X-ray Dark-Field Tomography
    Modregger, P.
    Wang, Z.
    Thuering, T.
    Pinzer, B.
    Stampanoni, M.
    10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY, 2011, 1365 : 269 - 272
  • [33] RING ARTIFACTS IN X-RAY COMPUTED-TOMOGRAPHY
    CRANAGE, RW
    TOFTS, PS
    BRITISH JOURNAL OF RADIOLOGY, 1988, 61 (726): : 529 - 529
  • [34] Analysis and correction of artifacts in X-ray industrial CT
    Zhang, QH
    Lu, HN
    Yang, M
    ISTM/2005: 6th International Symposium on Test and Measurement, Vols 1-9, Conference Proceedings, 2005, : 4999 - 5003
  • [35] Self-absorption correction in γ-ray efficiency calibration of fission gas nuclide
    Xie, Feng
    He, Xiao-Bing
    Bao, Min
    Jiang, Wen-Gang
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2010, 44 (10): : 1153 - 1156
  • [36] A new method to make gamma-ray self-absorption correction
    Tian, DF
    Xie, D
    Ho, YK
    Yang, FJ
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2001, 38 (08) : 655 - 657
  • [37] Effects of the Self-Absorption of X-ray Spectral Lines in the Presence of the Laser-Cluster Interaction
    Skobelev, I. Yu.
    Faenov, A. Ya.
    Pikuz, T. A.
    Pikuz, S. A., Jr.
    Fortov, V. E.
    Fukuda, Y.
    Hayashi, Y.
    Pirozhkov, A.
    Kawase, K.
    Kotaki, H.
    Shimomura, T.
    Kiriyama, H.
    Kato, Y.
    Kando, M.
    JETP LETTERS, 2011, 94 (04) : 270 - 276
  • [38] SELF-ABSORPTION METHOD OF X-RAY SPECTROSCOPY FOR INVESTIGATING UNOCCUPIED VALENCE STATES IN SOLIDS.
    Niederlag, W.
    Blau, W.
    Burenkov, A.
    Kleinstueck, K.
    Physics of Metals and Metallography, 1977, 43 (05): : 62 - 68
  • [39] Total electron yield method in x-ray absorption spectroscopy: A closer look at the saturation/self-absorption effects
    Chakarian, V
    Idzerda, YU
    JOURNAL OF APPLIED PHYSICS, 1997, 81 (08) : 4709 - 4709
  • [40] Elimination of self-absorption in fluorescence hard-x-ray absorption spectra
    Pfalzer, P
    Urbach, JP
    Klemm, M
    Horn, S
    denBoer, ML
    Frenkel, AI
    Kirkland, JP
    PHYSICAL REVIEW B, 1999, 60 (13): : 9335 - 9339