Parameterization of a model-based 3-D PET scatter correction

被引:33
|
作者
Wollenweber, SD [1 ]
机构
[1] GE Co, Med Syst, Milwaukee, WI 53201 USA
关键词
algorithms; positron emission tomography (PET); scattering parameters;
D O I
10.1109/TNS.2002.1039554
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Parameterization of a fast implementation of the Ollinger model-based 3-D scatter correction method [1] for positron emission tomography (PET) has been evaluated using measured phantom data acquired on a GE Advance PET imaging system. The Ollinger method explicitly estimates the 3-D single-scatter distribution using measured emission and transmission data and then estimates the multiple-scatter as a convolution of the single scatter. The main algorithm difference from that implemented by Ollinger is that the scatter correction does not explicitly compute scatter for azimuthal angles; rather, it determines 2-D scatter estimates for data within 2-D "super-slices" using as input data from the 3-D direct-plane (nonoblique) slices. These axial super-slice data are composed of data within a parameterized distance from the center of the super-slice. A model-based scatter correction method can be parameterized, and choice parameters may significantly change the behavior of the algorithm. Parameters studied in this work included transaxial image downsampling, the number of detectors to calculate scatter to, multiples kernel width and magnitude, the number and thickness of super-slices, and the number of scatter estimation iterations. Measured phantom data included imaging of the NEMA NU-2001 image quality (IQ) phantom, the IQ phantom with 2 cm extra water-equivalent tissue strapped around its circumference, and an attenuation phantom (20 cm uniform cylinder with Teflon, water and air inserts) with two 8 cm diameter water-filled nonradioactive arms placed by its side. For the IQ phantom data, a subset of NEMA NU-2001 measures were used to determine the contrast-to-noise ratio (CNR), lung residual bias, and background variability. For the attenuation phantom, region of interests (ROIs) were drawn on the nonradioactive compartments and on the background. These ROIs were analyzed for inter and intra-slice variation, background bias, and compartment-to-background ratio. In most cases, the algorithm was most sensitive to multiple-scatter parameterization and least sensitive to transaxial downsampling. The algorithm showed convergence by the second iteration for the metrics used in this study. Also, the range of the magnitude of change in the metrics analyzed was small over all changes in parameterization. Further work to extend these results to more realistic phantom and clinical datasets is warranted.
引用
收藏
页码:722 / 727
页数:6
相关论文
共 50 条
  • [21] A single scatter simulation technique for scatter correction in 3D pet
    Watson, CC
    Newport, D
    Casey, ME
    THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 1996, 4 : 255 - 268
  • [22] A 3-D model-based registration approach for the PET, MR and MCG cardiac data fusion
    Mäkelä, T
    Pham, QC
    Clarysee, P
    Nenonen, J
    Lötjönen, J
    Sipilä, O
    Hänninen, H
    Lauerma, K
    Knuti, J
    Katila, T
    Magnin, IE
    MEDICAL IMAGE ANALYSIS, 2003, 7 (03) : 377 - 389
  • [23] 3-D model-based people detection & tracking
    Garibotto, Giovanni
    2007 IEEE CONFERENCE ON ADVANCED VIDEO AND SIGNAL BASED SURVEILLANCE, 2007, : 579 - 584
  • [24] MODEL-BASED 3-D RECONSTRUCTION OF BRANCHING VESSELS
    FESSLER, J
    NISHIMURA, D
    MACOVSKI, A
    IMAGES OF THE TWENTY-FIRST CENTURY, PTS 1-6, 1989, 11 : 561 - 562
  • [25] Towards 3-D model-based video coding
    Soligon, O
    Le Mehaute, A
    Roux, C
    ANNALES DES TELECOMMUNICATIONS-ANNALS OF TELECOMMUNICATIONS, 1998, 53 (5-6): : 229 - 241
  • [26] Automatic 3-D model-based neuroanatomical segmentation
    Collins, DL
    Holmes, CJ
    Peters, TM
    Evans, AC
    HUMAN BRAIN MAPPING, 1995, 3 (03) : 190 - 208
  • [27] 3D Model-based partial volume correction for cardiac PET imaging in mice
    Dumouchel, Tyler
    deKemp, Robert
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [28] Midvein extraction for 3-D corn leaf model based on parameterization
    Zhao, Yuandi
    Wen, Weiliang
    Guo, Xinyu
    Xiao, Boxiang
    Lu, Shenglian
    Sun, Zhihui
    Nongye Jixie Xuebao/Transactions of the Chinese Society of Agricultural Machinery, 2012, 43 (04): : 183 - 187
  • [29] A comparative investigation of scatter correction in 3D PET
    Polycarpou, I.
    Marsden, P. K.
    Tsoumpas, C.
    INTERNATIONAL CONFERENCE ON IMAGE OPTIMISATION IN NUCLEAR MEDICINE (OPTINM), 2011, 317
  • [30] Advances in scatter correction for 3D PET/CT
    Watson, CC
    Casey, ME
    Michel, C
    Bendriem, B
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 3008 - 3012