Evaluation of median nerve by shear wave elastography and diffusion tensor imaging in carpal tunnel syndrome

被引:57
|
作者
Cingoz, Mehmet [1 ]
Kandemirli, Sedat Giray [1 ]
Alis, Deniz Can [1 ]
Samanci, Cesur [1 ]
Kandemirli, Guzin Cakir [2 ]
Adatepe, Nurten Uzun [3 ]
机构
[1] Istanbul Univ, Cerrahpasa Med Fac, Dept Radiol, Fatih Istanbul, Turkey
[2] Taksim Training & Res Hosp, Dept Phys Med & Rehabil, Istanbul, Turkey
[3] Istanbul Univ, Cerrahpasa Med Fac, Dept Neurol, Fatih Istanbul, Turkey
关键词
Carpal tunnel syndrome; Shear-wave elastography; Diffusion tensor imaging; Median nerve; INITIAL-EXPERIENCE; PRACTICE PARAMETER; PERIPHERAL-NERVE; DIAGNOSIS; MRI; ULTRASONOGRAPHY; SONOGRAPHY; STRAIN; TRACTOGRAPHY; CONDUCTION;
D O I
10.1016/j.ejrad.2018.02.005
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The aim of the current study is to investigate the diagnostic role of shear-wave elastography and diffusion tensor imaging in patients with carpal tunnel syndrome. Material and methods: The study included a total of 77 wrists; 18 normal, 35 wrists with mild, 9 wrists with moderate and 15 wrists with severe carpal tunnel syndrome. Elastography of the median nerve was performed by defining the boundaries of a segment of the nerve at sagittal plane at the level of proximal carpal row. Additionally, the cross-sectional area of the median nerve was evaluated. Fractional anisotropy and apparent diffusion coefficient measurements were carried out by placing region-of-interest at three levels: at pisiform bone (carpal tunnel inlet), mid carpal tunnel, and hook of hamate (carpal tunnel outlet). Results: Patients with carpal tunnel syndrome had higher elasticity values of median nerve (53.0 kPa; IQR 40.8-77.0 kPa) compared to control subjects. (36.8 kPa; IQR 31.0-39.9 kPa) Patients with moderate-severe carpal tunnel syndrome had higher elasticity values (82 kPa; IQR 64.0-95.5 kPa) compared to patients with mild carpal tunnel syndrome. (44 kPa; IQR 32.5-59.5 kPa) Patients with carpal tunnel syndrome had lower fractional anisotropy at mid-carpal level (0.382; IQR 0.330-0.495) compared to the control group. (0.494; IQR 0.434-0.537) Patients with moderate-severe carpal tunnel syndrome had lower fractional anisotropy values (0.366; IQR 0.331-0.407) and higher apparent diffusion coefficient values (1.509 mm(2)/s; IQR 1.374-1.733 mm(2)/s) compared to patients with mild carpal tunnel syndrome. (0,423; IQR 0.324-0.526 and 1.293 mm(2)/s; IQR 0.967-1.514 mm(2)/s) Conclusion: Shear-wave elastography and diffusion tensor imaging are helpful imaging modalities in diagnosing carpal tunnel syndrome and assessing its severity.
引用
收藏
页码:59 / 64
页数:6
相关论文
共 50 条
  • [31] Median nerve recovery in carpal tunnel syndrome
    Todnem, K
    Lundemo, G
    MUSCLE & NERVE, 2000, 23 (10) : 1555 - 1560
  • [32] Diagnosis of Carpal Tunnel Syndrome using Shear Wave Elastography and High-frequency Ultrasound Imaging
    Nam, Kibo
    Peterson, Shawn M.
    Wessner, Corinne E.
    Machado, Priscilla
    Forsberg, Flemming
    ACADEMIC RADIOLOGY, 2021, 28 (09) : E278 - E287
  • [33] Diagnostic Performance of Shear Wave Elastography for Carpal Tunnel Syndrome Combined with High Frequency Ultrasound Imaging
    Nam, Kibo
    Peterson, Shawn M.
    Wessner, Corinne E.
    Machado, Priscilla
    Forsberg, Flemming
    PROCEEDINGS OF THE 2020 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2020,
  • [34] Comparison of the Diagnostic Performance of Strain Elastography and Shear Wave Elastography for the Diagnosis of Carpal Tunnel Syndrome
    Park, Eun Joo
    Hahn, Seok
    Yi, Jisook
    Shin, Kyong Jin
    Lee, Yedaun
    Lee, Ho-Joon
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (05) : 1011 - 1021
  • [35] Magnetic resonance imaging evaluation of the median nerve using histogram analysis in carpal tunnel syndrome
    Baykara, Murat
    Koca, Tuba Tulay
    Demirel, Adnan
    Berk, Ejder
    NEUROLOGICAL SCIENCES AND NEUROPHYSIOLOGY, 2018, 35 (03): : 145 - 150
  • [36] Shear wave elastography is a valuable tool for diagnosing and grading carpal tunnel syndrome
    Renato Antonio Sernik
    Renata Fernandes Batista Pereira
    Giovanni Guido Cerri
    Rodrigo Sanford Damasceno
    Breno Braga Bastos
    Renata Vidal Leão
    Skeletal Radiology, 2023, 52 : 67 - 72
  • [37] Utility of shear wave elastography for diagnosing carpal tunnel syndrome with psoriatic arthritis
    Ezgi Akyildiz Tezcan
    Funda Levendoglu
    Mehmet Sedat Durmaz
    Elif Balevi Batur
    Ilknur Albayrak Gezer
    Kemal Erol
    Irish Journal of Medical Science (1971 -), 2024, 193 : 977 - 985
  • [38] Application of shear wave elastography and median nerve cross-section area in the diagnosis and staging of carpal tunnel syndrome: a case-control study
    Mohammadi, Afshin
    Afshar, Ahmadreza
    Mirza-Aghazadeh-Attari, Mohammad
    Mokhtari, Seyed Arman Seyed
    POLISH JOURNAL OF RADIOLOGY, 2021, 86 : E638 - E643
  • [39] Ultrasound elastographic evaluation of the median nerve in hemodialysis with carpal tunnel syndrome
    Hua Xin
    Hai-yang Hu
    Bin Liu
    Xiang Liu
    Xia Li
    Jie Li
    Journal of Medical Ultrasonics, 2017, 44 : 123 - 131
  • [40] Shear wave elastography is a valuable tool for diagnosing and grading carpal tunnel syndrome
    Sernik, Renato Antonio
    Pereira, Renata Fernandes Batista
    Cerri, Giovanni Guido
    Damasceno, Rodrigo Sanford
    Bastos, Breno Braga
    Leao, Renata Vidal
    SKELETAL RADIOLOGY, 2023, 52 (01) : 67 - 72