New g-functions for the hourly simulation of double U-tube borehole heat exchanger fields

被引:26
|
作者
Zanchini, E. [1 ]
Lazzari, S. [1 ]
机构
[1] Univ Bologna, Dept Ind Engn DIN, Bologna, Italy
关键词
Ground-coupled heat pumps; BHE (borehole heat exchanger) fields; Hourly simulation; g-functions; Finite element analysis; THERMAL RESPONSE TEST; FINITE LINE-SOURCE; GROUNDWATER-FLOW; SYSTEMS; PILE; PERFORMANCE; MODEL;
D O I
10.1016/j.energy.2014.04.022
中图分类号
O414.1 [热力学];
学科分类号
摘要
A new method for the hourly simulation of fields of long BHEs (borehole heat exchangers) is presented, in dimensionless form. The method considers also the internal structure of the BHE, with reference to double U-tube BHEs. The analytical expressions of new g-functions (time evolutions of the dimensionless temperature, averaged along the BHE length, due to a uniform and constant heat load) are presented, which complement those reported in Zanchini E., Lazzari S., Energy 2013; 59: 570-80. The new g-functions yield the dimensionless temperature at the interface tubes-grout, and allow a more precise determination of the time evolution of the temperature of the operating fluid during hourly peak loads. Moreover, g-functions at the interface tubes-grout and at several radial distances are reported also for BHEs with a ratio 500 between length and diameter, a value not considered in the previous paper. Due to its higher accuracy, the new method is recommended for the hourly simulation and the optimization of ground-coupled heap pump systems with double U-tube BHEs. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:444 / 455
页数:12
相关论文
共 50 条
  • [11] Thermal performance investigation of borehole heat exchanger with different U-tube diameter and borehole parameters
    Li, Yang
    An, Qingsong
    Liu, Liangxu
    Zhao, Jun
    INTERNATIONAL CONFERENCE ON APPLIED ENERGY, ICAE2014, 2014, 61 : 2690 - 2694
  • [12] EFFECTIVE BOREHOLE THERMAL RESISTANCE OF A SINGLE U-TUBE GROUND HEAT EXCHANGER
    Liao, Quan
    Zhou, Chao
    Cui, Wenzhi
    Jen, Tien-Chien
    NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2012, 62 (03) : 197 - 210
  • [13] Computer simulation of the U-tube ground heat exchanger for GSHP
    Key Laboratory-Enhanced Heat Transfer and Energy Conservation, College of Environmental and Energy Engineering, Beijing University of Technology, Beijing 100022, China
    不详
    Beijing Gongye Daxue Xuebao J. Beijing Univ. Technol., 2006, 1 (62-66):
  • [14] Transient heat transfer simulation, analysis and thermal performance study of double U-tube borehole heat exchanger based on numerical heat transfer model
    Kerme, Esa Dube
    Fung, Alan S.
    APPLIED THERMAL ENGINEERING, 2020, 173
  • [15] Transient heat transfer performance of a vertical double U-tube borehole heat exchanger under different operation conditions
    Zhu, Li
    Chen, Sarula
    Yang, Yang
    Sun, Yong
    RENEWABLE ENERGY, 2019, 131 : 494 - 505
  • [16] A new approach to the analysis of a tubesheet for a U-tube heat exchanger
    Paliwal, DN
    INTERNATIONAL JOURNAL OF PRESSURE VESSELS AND PIPING, 1996, 67 (02) : 181 - 184
  • [17] Analysis of short helical and double U-tube borehole heat exchangers: A simulation-based comparison
    Zarrella, Angelo
    Capozza, Antonio
    De Carli, Michele
    APPLIED ENERGY, 2013, 112 : 358 - 370
  • [18] Numerical simulation analysis on vertical U-tube underground heat exchanger
    Lian, Xiaoxin
    Liu, Jinxiang
    Chen, Xiaochun
    Li, Ying
    Ding, Gao
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2012, 33 (01): : 48 - 55
  • [19] A comprehensive transient heat transfer simulation of U-tube borehole heat exchanger considering porous media and subterranean water seepage
    Mehrpooya, Mehdi
    Ghafoorian, Farzad
    Afzal, Seyed Parsa Mohammadi
    Mirmotahari, Seyed Reza
    Ganjali, Mohammad Reza
    CHEMICAL PAPERS, 2024, 78 (11) : 6315 - 6329
  • [20] Numerical Simulation and Analysis for the U-tube Heat Exchanger of Ground Source Heat Pump
    Chang Zhen
    Guo Min
    2013 32ND CHINESE CONTROL CONFERENCE (CCC), 2013, : 8713 - 8717