Does ultrasound examination when the cervix is unfavorable improve the prediction of failed labor induction?

被引:52
|
作者
Roman, H
Verspyck, E
Vercoustre, L
Degre, S
Col, JY
Firmin, JM
Caron, P
Marpeau, L
机构
[1] Univ Hosp, Dept Obstet & Gynaecol, F-76031 Rouen, France
[2] Gen Hosp, Dept Obstet & Gynaecol, Le Havre, France
关键词
cervix; failed induction; labor; prediction; ultrasound;
D O I
10.1002/uog.1008
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Objective To compare the Bishop score, ultrasound cervical parameters and fetal fibronectin assessment for predicting failed labor induction when the cervix is unfavorable. Method A prospective observational study was performed in 106 consecutive pregnant women with a Bishop score less than or equal to 5 undergoing labor induction. Assessment of fetal fibronectin and ultrasound measurement of cervical length, cervical wedging and cervical lip areas were performed. The relationship between these parameters and failure of labor induction was determined. Results Failure of labor induction was defined as failure to reach a cervical dilatation of greater than or equal to 5 cm, and it occurred in 16 patients (15.1%). Induction failure was associated with low Bishop scores before (P = 0.004) and 6 h after the start of induction (P = 0.007), increased clinical cervical length (P = 0.02) and increased ultrasound anterior cervical lip area (P = 0.04). The logistic regression model identified the Bishop score before induction (odds ratio = 2.25; 95% CI, 1.30-3.91; P = 0.003) and the clinical cervical length (odds ratio = 3.95; 95% CI, 1.3-11.7; P = 0.01) as being independent Predictors of failed induction. To predict an induction failure, the best Bishop score cut-off value was 4, with a sensitivity of 87.5%, a specificity of 45.6%, a likelihood ratio of 1.58, a positive predictive value of 22.2% and a negative predictive value of 95.4%. Conclusion Compared with the Bishop score, cervical length by ultrasound is not a better predictor for the outcome of labor induction in an unfavorable cervix. Nevertheless, the Bishop score appears to be of poor predictive value for failed induction of labor. Copyright (C) 2004 ISUOG. Published by John Wiley Sons, Ltd.
引用
收藏
页码:357 / 362
页数:6
相关论文
共 50 条
  • [21] Induction of labor in high-risk nulliparous women with unfavorable cervix
    Carletti, Valerio
    Yacoub, Veronica
    Valensise, Herbert C.
    Maneschi, Francesco
    MINERVA OBSTETRICS AND GYNECOLOGY, 2024,
  • [22] Predicting cesarean delivery for women undergoing an induction of labor with an unfavorable cervix
    Levine, Lisa Danielle
    Downes, Katheryne L.
    Parry, Samuel
    Elovitz, Michal A.
    Srinivas, Sindhu K.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2017, 216 (01) : S277 - S277
  • [23] Elastography in the examination of the uterine cervix before labor induction
    Preis, Krzysztof
    Swiatkowska-Freund, Malgorzata
    Pankrac, Zofia
    GINEKOLOGIA POLSKA, 2010, 81 (10) : 757 - 761
  • [24] Failed Induction of Labor: Strategies to Improve the Success Rates
    Talaulikar, Vikram S.
    Arulkumaran, Sabaratnam
    OBSTETRICAL & GYNECOLOGICAL SURVEY, 2011, 66 (11) : 717 - 728
  • [25] Balloon catheter for induction of labor in women with one previous cesarean and an unfavorable cervix
    Huisman, Claartje M. A.
    ten Eikelder, Mieke L. G.
    Mast, Kelly
    Rengerink, Katrien Oude
    Jozwiak, Marta
    van Dunne, Frederique
    Duvekot, Johannes J.
    van Eyck, Jim
    Gaugler-Senden, Ingrid
    de Groot, Christianne J. M.
    Franssen, Maureen T. M.
    van Gemund, Nicolette
    Langenveld, Josje
    de Leeuw, Jan Willem
    Lohuis, Eefje J. Oude
    Oudijk, Martijn A.
    Papatsonis, Dimitri
    van Pampus, Marielle
    Porath, Martina
    Rombout-de Weerd, Sabina
    van Roosmalen, Jos J.
    van der Salm, Paulien C. M.
    Scheepers, Hubertina C. J.
    Sikkema, Marko J.
    Sporken, Jan
    Stigter, Rob H.
    van Wijngaarden, Wim J.
    Woiski, Mallory
    Mol, Ben Willem J.
    Bloemenkamp, Kitty W. M.
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2019, 98 (07) : 920 - 928
  • [26] A validated calculator to estimate risk of cesarean after an induction of labor with an unfavorable cervix
    Abraham, Cynthia
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2018, 219 (04) : 420 - 421
  • [27] NONPHARMACEUTICAL RIPENING OF THE UNFAVORABLE CERVIX AND INDUCTION OF LABOR BY A NOVEL DOUBLE BALLOON DEVICE
    BLUMENTHAL, PD
    GAFFIKIN, L
    OBSTETRICS AND GYNECOLOGY, 1991, 77 (06): : 967 - 968
  • [28] A validated calculator to estimate risk of cesarean after an induction of labor with an unfavorable cervix
    Levine, Lisa D.
    Downes, Katheryne L.
    Parry, Samuel
    Elovitz, Michal A.
    Sammel, Mary D.
    Srinivas, Sindhu K.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2018, 218 (02) : 254.e1 - 254.e7
  • [29] NONPHARMACEUTICAL RIPENING OF THE UNFAVORABLE CERVIX AND INDUCTION OF LABOR BY A NOVEL DOUBLE BALLOON DEVICE
    ATAD, J
    BORNSTEIN, J
    CALDERON, I
    PETRIKOVSKY, BM
    SOROKIN, Y
    ABRAMOVICI, H
    OBSTETRICS AND GYNECOLOGY, 1991, 77 (01): : 146 - 152
  • [30] PREPARATION FOR INDUCTION OF LABOR OF THE UNFAVORABLE CERVIX WITH FOLEY CATHETER COMPARED WITH VAGINAL PROSTAGLANDIN
    THOMAS, IL
    CHENOWETH, JN
    TRONC, GN
    JOHNSON, IR
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1986, 26 (01): : 30 - 35