A kernel-based method for markerless tumor tracking in kV fluoroscopic images

被引:22
|
作者
Zhang, Xiaoyong [1 ]
Homma, Noriyasu [1 ]
Ichiji, Kei [2 ]
Abe, Makoto [2 ]
Sugita, Norihiro [2 ]
Takai, Yoshihiro [3 ]
Narita, Yuichiro [3 ]
Yoshizawa, Makoto [4 ]
机构
[1] Tohoku Univ, Grad Sch Med, Sendai, Miyagi 980, Japan
[2] Tohoku Univ, Grad Sch Engn, Sendai, Miyagi 980, Japan
[3] Hirosaki Univ, Grad Sch Med, Hirosaki, Aomori, Japan
[4] Tohoku Univ, Cybersci Ctr, Sendai, Miyagi 980, Japan
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2014年 / 59卷 / 17期
关键词
radiation therapy; markerless tumor tracking; computer vision; mean shift algorithm; LUNG-CANCER RADIOTHERAPY; IMPLANTED FIDUCIAL MARKERS; DEEP-INSPIRATION; BREATH-HOLD; PULMONARY NODULES; RADIATION-THERAPY; MOTION; FEASIBILITY; RESPIRATION; CT;
D O I
10.1088/0031-9155/59/17/4897
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Markerless tracking of respiration-induced tumor motion in kilo-voltage (kV) fluoroscopic image sequence is still a challenging task in real time image- guided radiation therapy (IGRT). Most of existing markerless tracking methods are based on a template matching technique or its extensions that are frequently sensitive to non-rigid tumor deformation and involve expensive computation. This paper presents a kernel-based method that is capable of tracking tumor motion in kV fluoroscopic image sequence with robust performance and low computational cost. The proposed tracking system consists of the following three steps. To enhance the contrast of kV fluoroscopic image, we firstly utilize a histogram equalization to transform the intensities of original images to a wider dynamical intensity range. A tumor target in the first frame is then represented by using a histogram-based feature vector. Subsequently, the target tracking is then formulated by maximizing a Bhattacharyya coefficient that measures the similarity between the tumor target and its candidates in the subsequent frames. The numerical solution for maximizing the Bhattacharyya coefficient is performed by a mean-shift algorithm. The proposed method was evaluated by using four clinical kV fluoroscopic image sequences. For comparison, we also implement four conventional template matching-based methods and compare their performance with our proposed method in terms of the tracking accuracy and computational cost. Experimental results demonstrated that the proposed method is superior to conventional template matching-based methods.
引用
收藏
页码:4897 / 4911
页数:15
相关论文
共 50 条
  • [21] Kernel-based 3D tracking
    Tyagi, Ambrish
    Keck, Mark
    Davis, James W.
    Potamianos, Gerasimos
    2007 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOLS 1-8, 2007, : 3750 - +
  • [22] An Improved Adaptive Kernel-based Object Tracking
    Liu Zhenghua
    Han Li
    MANUFACTURING SCIENCE AND TECHNOLOGY, PTS 1-8, 2012, 383-390 : 7588 - 7594
  • [23] Kernel-Based Structural Binary Pattern Tracking
    Kim, Dae-Hwan
    Kim, Hyo-Kak
    Lee, Seung-Jun
    Park, Won-Jae
    Ko, Sung-Jea
    IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 2014, 24 (08) : 1288 - 1300
  • [24] Kernel-based tracking from a probabilistic viewpoint
    Nguyen, Quang Anh
    Robles-Kelly, Antonio
    Shen, Chunhua
    2007 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOLS 1-8, 2007, : 2070 - +
  • [25] Scale Invariant Kernel-Based Object Tracking
    Li, Peng
    Cai, Zhipeng
    Wang, Hanyun
    Sun, Zhuo
    Yi, Yunhui
    Wang, Cheng
    Li, Jonathan
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON COMPUTER VISION IN REMOTE SENSING, 2012, : 252 - 255
  • [26] A kernel-based approach to categorizing laryngeal images
    Verikas, A.
    Gelzinis, A.
    Bacauskiene, M.
    Valincius, D.
    Uloza, V.
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2007, 31 (08) : 587 - 594
  • [27] Markerless Tumor Tracking via Clustering on Low-Rank Fluoroscopic Images for Image-Guided Lung Cancer Radiotherapy
    Huang, Wei
    Jia, Xun
    Dong, Bin
    Gu, Xuejun
    Cervino, Laura
    Gao, Hao
    Cai, Jian-Feng
    Jiang, Steve B.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [28] Markerless Lung Tumor Localization From Intraoperative Stereo Color Fluoroscopic Images for Radiotherapy
    Yan, Yongxuan
    Fujii, Fumitake
    Shiinoki, Takehiro
    Liu, Shengping
    IEEE ACCESS, 2024, 12 : 40809 - 40826
  • [29] A spectral-textural kernel-based classification method of remotely sensed images
    Gao, Jianqiang
    Xu, Lizhong
    Huang, Fengchen
    NEURAL COMPUTING & APPLICATIONS, 2016, 27 (02): : 431 - 446
  • [30] A topographic kernel-based regression method
    Nishida, K
    Takahashi, T
    Kurita, T
    PROCEEDINGS OF THE 6TH JOINT CONFERENCE ON INFORMATION SCIENCES, 2002, : 521 - 524