Variable Tidal Volumes Improve Lung Protective Ventilation Strategies in Experimental Lung Injury

被引:119
|
作者
Spieth, Peter M.
Carvalho, Alysson R.
Pelosi, Paolo [2 ]
Hoehn, Catharina
Meissner, Christoph
Kasper, Michael [3 ]
Huebler, Matthias
von Neindorff, Matthias
Dassow, Constanze [4 ]
Barrenschee, Martina [4 ]
Uhlig, Stefan [4 ]
Koch, Thea
de Abreu, Marcelo Gama [1 ]
机构
[1] Univ Hosp Dresden, Clin Anesthesiol & Intens Care Therapy, Dept Anesthesiol & Intens Care Therapy, D-01307 Dresden, Germany
[2] Univ Insubria, Dept Ambient Hlth & Safety, Varese, Italy
[3] Univ Dresden, Inst Anat, Dresden, Germany
[4] Univ Aachen, Inst Pharmacol & Toxicol, D-5100 Aachen, Germany
关键词
mechanical ventilation; acute lung injury; experimental model; variable ventilation; inflammation; IMPROVED ARTERIAL OXYGENATION; OLEIC-ACID; MECHANICAL VENTILATION; PORCINE MODEL; LAVAGE; VARIABILITY; PRESSURES; BENEFITS;
D O I
10.1164/rccm.200806-975OC
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Rationale: Noisy ventilation with variable VT may improve respiratory function in acute lung injury. Objectives: To determine the impact of noisy ventilation on respiratory function and its biological effects on lung parenchyma compared with conventional protective mechanical ventilation strategies. Methods: In a porcine surfactant depletion model of lung injury, we randomly combined noisy ventilation with the ARDS Network protocol or the open lung approach (n = 9 per group). Measurements and Main Results: Respiratory mechanics, gas exchange, and distribution of pulmonary blood flow were measured at intervals over a 6-hour period. Postmortem, lung tissue was analyzed to determine histological damage, mechanical stress, and inflammation. We found that, at comparable minute ventilation, noisy ventilation (1) improved arterial oxygenation and reduced mean inspiratory peak airway pressure and elastance of the respiratory system compared with the ARDS Network protocol and the open lung approach, (2) redistributed pulmonary blood flow to caudal zones compared with the ARDS Network protocol and to peripheral ones compared with the open lung approach, (3) reduced histological damage in comparison to both protective ventilation strategies, and (4) did not increase lung inflammation or mechanical stress. Conclusions: Noisy ventilation with variable VT and fixed respiratory frequency improves respiratory function and reduces histological damage compared with standard protective ventilation strategies.
引用
收藏
页码:684 / 693
页数:10
相关论文
共 50 条
  • [31] Lung protective strategies of ventilation in the neonate: What are they?
    Clark, RH
    Slutsky, AS
    Gerstmann, DR
    PEDIATRICS, 2000, 105 (01) : 112 - 114
  • [32] Association between use of lung-protective ventilation with lower tidal volumes and risk of acute lung injury, mortality, pulmonary infection, and atelectasis: a meta-analysis
    VGM Pereira
    A Serpa Neto
    SO Cardoso
    JA Manetta
    DC Espósito
    M de Oliveira Prado Pasqualucci
    MJ Schultz
    Critical Care, 17 (Suppl 3):
  • [33] Intraoperative protective ventilation strategies in lung transplantation
    Verbeek, Genna L.
    Myles, Paul S.
    TRANSPLANTATION REVIEWS, 2013, 27 (01) : 30 - 35
  • [34] One-lung ventilation with fixed and variable tidal volumes on oxygenation and pulmonary outcomes: A randomized trial
    Szamos, Katalin
    Balla, Boglarka
    Paloczi, Balazs
    Enyedi, Attila
    Sessler, Daniel I.
    Flesdi, Bela
    Vegh, Tamas
    JOURNAL OF CLINICAL ANESTHESIA, 2024, 95
  • [35] Protective ventilation strategies in the management of phosgene-induced acute lung injury
    Parkhouse, Duncan A.
    Brown, Roger F.
    Jugg, Bronwen J.
    Harban, Fraser M.
    Platt, Jan
    Kenward, Christopher E.
    Jenner, John
    Rice, Paul
    Smith, Adam J.
    MILITARY MEDICINE, 2007, 172 (03) : 295 - 300
  • [36] Ventilation with low tidal volumes during upper abdominal surgery does not improve postoperative lung function
    Treschan, T. A.
    Kaisers, W.
    Schaefer, M. S.
    Bastin, B.
    Schmalz, U.
    Wania, V.
    Eisenberger, C. F.
    Saleh, A.
    Weiss, M.
    Schmitz, A.
    Kienbaum, P.
    Sessler, D. I.
    Pannen, B.
    Beiderlinden, M.
    BRITISH JOURNAL OF ANAESTHESIA, 2012, 109 (02) : 263 - 271
  • [37] A Study of Inflammatory Response and Lung Injury Induced by Variable Tidal Volumes in Mechanically Ventilated Children
    Ismail, Ahlam M.
    El-Deen, Zeinab M. Mohey
    El Karn, Ibtsam Faarouk M.
    Sayed, Mohamed M.
    Baseer, Khaled A. Abdel
    INTERNATIONAL JOURNAL OF PEDIATRICS-MASHHAD, 2021, 9 (03): : 13193 - 13201
  • [38] Combining "open-lung" ventilation and arteriovenous extracorporeal lung assist: Influence of different tidal volumes on gas exchange in experimental lung failure
    Muellenbach, Ralf M.
    Kredel, Markus
    Kuestermann, Julian
    Klingelhoefer, Michael
    Schuster, Frank
    Wunder, Christian
    Kranke, Peter
    Roewer, Norbert
    Brederlau, Joerg
    MEDICAL SCIENCE MONITOR, 2009, 15 (08): : BR213 - BR220
  • [39] Variable rate ventilation strategies for the injured lung
    Gebber, Gerard L.
    Barman, Susan M.
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2008, 55 (09): : 572 - 576
  • [40] Evaluation Of A Web Based Intervention To Improve Adherence To Lung Protective Ventilation: The Lung Injury Knowledge Network (link)
    Rubenfeld, G. D.
    Manoharan, V.
    Scales, D. C.
    Dev, S.
    Caldwell, E.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2017, 195