Two-Dimensional Analytical Permanent-Magnet Eddy-Current Loss Calculations in Slotless PMSM Equipped With Surface-Inset Magnets

被引:85
|
作者
Dubas, Frederic [1 ]
Rahideh, Akbar [2 ]
机构
[1] Univ Franche Comte, FEMTO ST Inst, Dept Energy, F-90010 Belfort, France
[2] Shiraz Univ Technol, Sch Elect & Elect Engn, Shiraz 13876, Iran
关键词
Armature reaction; eddy-current; permanent-magnet (PM) machines; resistance-limited; skin-limited; synchronous; ARMATURE REACTION FIELD; BRUSHLESS AC MACHINES; SYNCHRONOUS MOTORS; CARRIER HARMONICS; MOUNTED MAGNETS; ROTOR LOSS; DC MOTORS; WINDINGS; STATOR; SEGMENTATION;
D O I
10.1109/TMAG.2013.2285525
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two-dimensional (2-D) analytical permanent-magnet (PM) eddy-current loss calculations are presented for slotless PM synchronous machines (PMSMs) with surface-inset PMs considering the current penetration effect. In this paper, the term slotless implies that either the stator is originally slotted but the slotting effects are neglected or the stator is originally slotless. The analytical magnetic field distribution is computed in polar coordinates from the 2-D subdomain method (i.e., based on formal resolution of Maxwell's equation applied in subdomain). Based on the predicted magnetic field distribution, the eddy-currents induced in the PMs are analytically obtained and the PM eddy-current losses considering eddy-current reaction field are calculated. The analytical expressions can be used for slotless PMSMs with any number of phases and any form of current and overlapping winding distribution. The effects of stator slotting are neglected and the current density distribution is modeled by equivalent current sheets located on the slot opening. To evaluate the efficacy of the proposed technique, the 2-D PM eddy-current losses for two slotless PMSMs are analytically calculated and compared with those obtained by 2-D finite-element analysis (FEA). The effects of the rotor rotational speed and the initial rotor mechanical angular position are investigated. The analytical results are in good agreement with those obtained by the 2-D FEA.
引用
收藏
页码:54 / 73
页数:20
相关论文
共 50 条
  • [31] APPROXIMATE CALCULATIONS OF TWO-DIMENSIONAL MODELS IN THE THEORY OF EDDY-CURRENT INSPECTION WITH SUPERPOSED TRANSDUCERS
    FEDOSENKO, YK
    SOVIET JOURNAL OF NONDESTRUCTIVE TESTING-USSR, 1982, 18 (06): : 466 - 472
  • [32] Analyses of Circulating-current Loss in Armature Windings and In-plane Eddy-current Loss in Electrical Steel Sheets of Permanent-magnet Synchronous Machines
    Ohguchi, Hideki
    Imamori, Satoshi
    Yamazaki, Katsumi
    Yui, Haiyan
    Shuto, Masao
    IEEJ JOURNAL OF INDUSTRY APPLICATIONS, 2019, 8 (03) : 452 - 457
  • [33] Exact Two-Dimensional Analytical Calculations for Magnetic Field, Electromagnetic Torque, UMF, Back-EMF, and Inductance of Outer Rotor Surface Inset Permanent Magnet Machines
    Vahaj, AmirAbbas
    Rahideh, Akbar
    Moayed-Jahromi, Hossein
    Ghaffari, AliReza
    MATHEMATICAL AND COMPUTATIONAL APPLICATIONS, 2019, 24 (01)
  • [34] Analytical magnetic field distribution of slotless brushless permanent magnet motors - Part I. Armature reaction field, inductance and rotor eddy current loss calculations
    Rahideh, A.
    Korakianitis, T.
    IET ELECTRIC POWER APPLICATIONS, 2012, 6 (09) : 628 - 638
  • [35] Analytical Solution of Magnetic Field in Permanent-Magnet Eddy-Current Couplings by Considering the Effects of Slots and Iron-Core Protrusions
    Dai, Xin
    Liang, Qinghua
    Ren, Chao
    Cao, Jiayong
    Mo, Jinqiu
    Wang, Shigang
    JOURNAL OF MAGNETICS, 2015, 20 (03) : 273 - 283
  • [36] Three-dimensional Analytical Model of Eddy Current Loss of Permanent Magnet in High Frequency Axial Flux Permanent Magnet Machine
    Tong W.
    Li J.
    Cao B.
    Wu S.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2021, 41 (06): : 1992 - 2001
  • [37] Analytical modeling of eddy-current losses caused by pulse-width-modulation switching in permanent-magnet brushless direct-current motors
    Deng, Fang
    Nehl, Thomas W.
    IEEE Transactions on Magnetics, 1998, 34 (5 pt 2): : 3728 - 3736
  • [38] Analytical modeling of eddy-current losses caused by pulse-width-modulation switching in permanent-magnet brushless direct-current motors
    Deng, F
    Nehl, TW
    IEEE TRANSACTIONS ON MAGNETICS, 1998, 34 (05) : 3728 - 3736
  • [39] Eddy current loss in double-sided cored slotless type permanent magnet linear synchronous generator using analytical method
    Jang, Gang-Hyeon
    Koo, Min-Mo
    Seo, Sung-Won
    Hong, Keyyong
    Choi, Jang-Young
    AIP ADVANCES, 2017, 7 (05):
  • [40] Analytical Modeling and Experimental Validation of Rotor Harmonic Eddy-Current Loss in High-Speed Surface-Mounted Permanent Magnet Motors
    Zhang, Zhongming
    Deng, Zhiquan
    Sun, Quangui
    Peng, Cong
    Gu, Yu
    Pang, Gucai
    IEEE TRANSACTIONS ON MAGNETICS, 2019, 55 (02)