Determination of cadmium and lead in fruit juices by stripping chronopotentiometry and comparison of two sample pretreatment procedures

被引:26
|
作者
Lo Coco, F.
Monotti, P.
Cozzi, F.
Adami, G.
机构
[1] Univ Udine, Dept Econ Sci, Environm & Agroind Sect, I-33100 Udine, Italy
[2] Chem Lab Steroglass, Perugia, Italy
[3] Univ Trieste, Dept Chem Sci, Trieste, Italy
关键词
stripping chronopotentiometry; cadmium; lead; fruit juices;
D O I
10.1016/j.foodcont.2005.06.015
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
A method for the determination of cadmium and lead in apple and pear fruit juices by stripping chronopotentiometry (SCP) is described. The results obtained after previous digestion of the sample with concentrated sulphuric acid and dry-ashing (sample pretreatment procedure "A") and after a treatment with concentrated hydrochloric acid followed by heating in hot water bath (sample pretreatment procedure "B") were compared. The sample pretreatment procedures were tested on real fruit juice samples and all data confirmed that the efficiency of procedure A was greater than procedure B. In particular, for samples treated with procedure A, good linearity was obtained in the range of examined concentration as is shown by the determination coefficients that were 0.998 (n = 4) for cadmium and 0.996 (n = 4) for lead. Recoveries of 86-104% for cadmium and of 87-102% for lead were obtained from a sample spiked at different levels. The accuracy was also evaluated by means of a matching reference sample of spiked skim milk powder (BCR 150-Community Bureau of Reference) to prove the reliability of the method. The detection limits were 2.0 ng g(-1) for cadmium and 4.8 ng g(-1) for lead. The relative standard deviations (mean of nine determinations), evaluated on a real sample, were 7.8% and 6.5% respectively. The average content was in the range not detectable-3.0 ng g(-1) for cadmium and 8.2-21.3 ng g(-1) for lead. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:966 / 970
页数:5
相关论文
共 50 条
  • [41] Comparison of Simple and Rapid Extraction Procedures for the Determination of Pesticide Residues in Fruit Juices by Fast Gas Chromatography–Mass Spectrometry
    Laura Cherta
    Joaquim Beltran
    Elena Pitarch
    Félix Hernández
    Food Analytical Methods, 2013, 6 : 1671 - 1684
  • [42] Determination of quinclorac by adsorptive stripping voltammetry in rice samples without sample pretreatment
    Liberato, Priscila A.
    Okumura, Leonardo L.
    Silva, Astrea F. S.
    Gurgel, Alexandre
    Aleixo, Herbert
    Silva, Junio G.
    de Oliveira, Andre Fernando
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2021, 56 (09) : 828 - 837
  • [43] Application and Comparison of Methods of Antioxidant Activity Determination in Fruit and Vegetable Juices
    Holasova, Marie
    Fiedlerova, Vlasta
    CHEMICKE LISTY, 2011, 105 (10): : 766 - 772
  • [44] Determination and comparison of the total polyphenol contents of fresh and commercial fruit juices
    Mahdavi, Reza
    Nikniaz, Zeinab
    Rafraf, Maryam
    Jouyban, Abolghasem
    BRITISH FOOD JOURNAL, 2011, 113 (6-7): : 744 - 752
  • [45] DETERMINATION OF ZINC, CADMIUM, LEAD AND COPPER IN A SINGLE SEA-WATER SAMPLE BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    ABDULLAH, MI
    BERG, BR
    KLIMEK, R
    ANALYTICA CHIMICA ACTA, 1976, 84 (02) : 307 - 317
  • [46] THE DETERMINATION OF COPPER, LEAD AND CADMIUM IN AN OYSTER HOMOGENATE BY ANODIC-STRIPPING VOLTAMMETRY
    LUND, W
    SAGBERG, P
    ANALYTICA CHIMICA ACTA, 1980, 115 (MAR) : 337 - 341
  • [47] SIMULTANEOUS DETERMINATION OF COPPER, CADMIUM, LEAD AND ZINC IN WATER BY ANODIC STRIPPING POLAROGRAPHY
    SINKO, I
    DOLEZAL, J
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1970, 25 (02): : 299 - &
  • [48] SIMULTANEOUS DETERMINATION OF LEAD, CADMIUM AND ZINC IN AEROSOLS BY ANODIC-STRIPPING VOLTAMMETRY
    KHANDEKAR, RN
    DHANESHWAR, RG
    PALRECHA, MM
    ZARAPKAR, LR
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1981, 307 (05): : 365 - 368
  • [49] Determination of lead and cadmium in titanium dioxide by differential pulse anodic stripping voltammetry
    Panigati, M
    Piccone, M
    D'Alfonso, G
    Orioli, M
    Carini, M
    TALANTA, 2002, 58 (03) : 481 - 488
  • [50] SIMULTANEOUS DETERMINATION OF CADMIUM AND LEAD IN URINE BY MEANS OF COMPUTERIZED POTENTIOMETRIC STRIPPING ANALYSIS
    JAGNER, D
    JOSEFSON, M
    WESTERLUND, S
    ANALYTICA CHIMICA ACTA, 1981, 128 (JUL) : 155 - 161