Specific formulas improve the estimation of fetal weight by ultrasound scan

被引:18
|
作者
Souka, Athena P. [1 ,2 ]
Papastefanou, Ioannis [1 ]
Michalitsi, Vasiliki [1 ]
Pilalis, Athanasios [1 ,2 ]
Kassanos, Dimitrios [1 ]
机构
[1] Univ Athens, Fetal Med Unit, Dept Obstet & Gynaecol 3, Attikon Univ Hosp, Athens, Greece
[2] Leto Matern Hosp, Fetal Med Unit, Athens, Greece
来源
关键词
Accuracy; biometry; birth weight; equation; growth; third trimester; PREDICTION; PERFORMANCE; FETUSES; MODEL;
D O I
10.3109/14767058.2013.837877
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To develop and evaluate local, sex specific, small for gestational age (SGA) specific, large for gestational age (LGA) specific and combined (biometry, sex and Doppler indices) formulas for ultrasound estimated fetal weight (EFW). Method: Low-risk singleton pregnancies that delivered within 7 days from ultrasound examination were assessed. A formula-generating group (1407 pregnancies) and a validation group (469 pregnancies) were created. Fractional regression analysis was used to develop the formulas. Systematic error, random error, fraction within the 10% of actual birth weight and Bland-Altman analysis were used. Results: The local formula and the Hadlock formula with local co-efficients performed better than the Hadlock formula. The SGA-specific formula, the LGA-specific formula and the combined formula had the lower systematic error (MSE: +0.0022291, -0.4226888, +0.8386222, respectively) and the narrower 95% LOA (-292.8 to +292.23, -485.6 to +461.5, -425.7 to +450.46, respectively). The SGA- and the LGA-specific formulas had higher fraction within the 10% of actual birth weight (81.5% and 84%, respectively). Conclusions: Local formulas improve the EFW calculation. The combined formula can further optimize the accuracy and precision. Application of specific formulas for the small and the large fetus had the most pronounced effect in improving fetal weight estimation.
引用
收藏
页码:737 / 742
页数:6
相关论文
共 50 条
  • [41] Fetal ultrasound image segmentation system and its use in fetal weight estimation
    Yu, Jinhua
    Wang, Yuanyuan
    Chen, Ping
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2008, 46 (12) : 1227 - 1237
  • [42] Fetal ultrasound image segmentation system and its use in fetal weight estimation
    Jinhua Yu
    Yuanyuan Wang
    Ping Chen
    Medical & Biological Engineering & Computing, 2008, 46
  • [43] Ultrasound macrosomic fetal weight estimation formula using maternal weight measurements
    Murlewska, Julia
    Pietryga, Marek
    Wender-Ozegowska, Ewa
    GINEKOLOGIA POLSKA, 2011, 82 (02) : 114 - 118
  • [44] FETAL WEIGHT ESTIMATION FORMULAS WITH HEAD, ABDOMINAL, FEMUR, AND THIGH CIRCUMFERENCE MEASUREMENTS
    VINTZILEOS, AM
    CAMPBELL, WA
    RODIS, JF
    BORSKOEFOED, R
    NOCHIMSON, DJ
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1987, 157 (02) : 410 - 414
  • [45] Ultrasound estimation of fetal weight using a new Birth Weight Prediction Model
    Stetzer, B
    Thomas, A
    Amini, S
    Catalano, P
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2001, 185 (06) : S254 - S254
  • [46] The birth weight of macrosomia influence the accuracy of ultrasound estimation of fetal weight at term
    Song, JinShuang
    Liu, JingHua
    Liu, Li
    Jiang, Ying
    Zheng, HongPing
    Ke, Hualing
    Yang, LiLi
    Zhang, ZongYu
    JOURNAL OF CLINICAL ULTRASOUND, 2022, 50 (07) : 967 - 973
  • [47] ACCURATE ULTRASONIC ESTIMATION OF FETAL WEIGHT - PROSPECTIVE ANALYSIS OF NEW ULTRASONIC FORMULAS
    OTT, WJ
    DOYLE, S
    FLAMM, S
    WITTMAN, J
    AMERICAN JOURNAL OF PERINATOLOGY, 1986, 3 (04) : 307 - 310
  • [48] The accuracy of ultrasound estimation of fetal weight in comparison to birth weight: A systematic review
    Milner, Julia
    Arezina, Jane
    ULTRASOUND, 2018, 26 (01) : 32 - 41
  • [49] ULTRASONOGRAPHIC ESTIMATION OF FETAL WEIGHT DURING LABOR - EVALUATION AND COMPARISON OF 2 FORMULAS
    HANRETTY, KP
    FABER, BL
    SOUTH AFRICAN MEDICAL JOURNAL, 1988, 73 (03): : 181 - 182
  • [50] A COMPARISON OF FETAL WEIGHT ESTIMATION FORMULAS WITH AND WITH-OUT ULTRASONIC MEASUREMENTS OF THE HEAD
    WARSOF, S
    WOLFE, P
    COULEHAN, J
    QUEENAN, JT