Safety of Internal Electronic Fetal Heart Rate Monitoring During Labor

被引:1
|
作者
Liang, Yiheng [1 ,2 ]
Li, Yun [1 ]
Huang, Chunhua [1 ]
Li, Xiaohong [1 ]
Cai, Qiaoqing [1 ]
Peng, Jiying [2 ]
Fan, Shangrong [1 ,3 ]
机构
[1] Peking Univ Shenzhen Hosp, Dept Obstet & Gynecol, Shenzhen 518036, Peoples R China
[2] Peking Univ Shenzhen Hosp, Dept Pathol, Shenzhen 518036, Peoples R China
[3] Shenzhen Key Lab Technol Early Diag Major Gynecol, Shenzhen 518036, Peoples R China
基金
中国国家自然科学基金;
关键词
Fetal monitoring; Neonatal academia; Cesarean section; Chorioamnionitis; Puerperal morbidity; Puerperal infection; SCALP ELECTRODE; ABSCESS;
D O I
10.1097/FM9.0000000000000145
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To investigate the safety and efficacy of internal electronic fetal heart rate (FHR) monitoring during labor. Methods: This was a retrospective case-control study, which was an analysis of monitoring FHR with a fetal scalp electrode or a Doppler probe (94 pregnant women per group), In the internal monitoring group, when the opening of the uterine orifice was >= 3 cm, the fetal scalp electrode was placed after natural or artificial rupture of the membrane. FHR was simultaneously monitored using a Doppler probe. In the external monitoring group, continuous FHR monitoring was performed using an ultrasound Doppler transducer fixed on the maternal abdomen. The toco transducer was used to record uterine contractions. Pathological examination of the placenta was performed prospectively in 49 and 48 cases in the internal electronic FHR monitoring group and control group, respectively. Maternal-infant outcomes (e.g. fever, puerperal infection, puerperal morbidity, delivery mode, Apgar score, and scalp injury) were recorded. Umbilical artery blood was extracted for blood gas analysis. Differences between the two groups were compared using the paired t-test, chi(2) test, Yates corrected chi(2) test or Fisher exact test. Results: Non-statistically significant differences between the internal and external monitoring groups were observed in the incidence of neonatal acidosis (1/94 (1.06%) vs. 3/94 (3.19%), respectively; chi(2)= 0 .255, P=0.613), cesarean section/operative vaginal delivery (8/94 (8.51%) vs. 15/94 (15.96%), respectively; chi(2) = 2.427, P=0.181), fever during labor (18/94 (19.15%) vs. 15/94 (15.96%), respectively; chi(2) = 0. 331, P= 0.565), puerperal morbidity (2/94 (2.13%) vs. 3/94 (3.19%), respectively; chi(2) = 0.000, P = 1.000), chorioamnionitis (9/49 (18.37%) vs. 7/48(14.58%), respectively; chi(2 )=0.252, P= 0.616), and neonatal asphyxia (0/94 (0.00%) vs. 1/94 (1.06%), respectively; chi(2 )= 0 .000, p=1.000). There were no puerperal infections, neonatal scalp injuries, or scalp abscesses found in either group. Using the internal monitoring value as reference, the incidence of FHR false deceleration in external FHR monitoring was 20.21% (19/94 women). Conclusion: Internal FHR monitoring during labor does not increase the incidence of adverse perinatal outcomes. External monitoring was associated with FHR false decelerations.
引用
收藏
页码:121 / 126
页数:6
相关论文
共 50 条
  • [31] Medicolegal ramifications of electronic fetal monitoring during labor
    Schifrin, BS
    CLINICS IN PERINATOLOGY, 1995, 22 (04) : 837 - &
  • [32] A PLACE FOR ELECTRONIC FETAL MONITORING DURING LABOR - REPLY
    SMITH, M
    RUFFIN, M
    GREEN, L
    AMERICAN FAMILY PHYSICIAN, 1994, 49 (04) : 755 - &
  • [33] IS FETAL HEART-RATE MONITORING SUFFICIENTLY SENSITIVE TO DETECT CHANGES DURING LABOR
    BARTLETT, MLR
    MURRAY, A
    DUNLOP, W
    JOURNAL OF BIOMEDICAL ENGINEERING, 1992, 14 (05): : 431 - 434
  • [34] METHODS OF FETAL HEART-RATE MONITORING DURING LABOR - A SELECTIVE REVIEW OF THE LITERATURE
    SNYDAL, SH
    JOURNAL OF NURSE-MIDWIFERY, 1988, 33 (01): : 4 - 14
  • [35] Toward the improvement in fetal monitoring during labor with the inclusion of maternal heart rate analysis
    Hernâni Gonçalves
    Paula Pinto
    Manuela Silva
    Diogo Ayres-de-Campos
    João Bernardes
    Medical & Biological Engineering & Computing, 2016, 54 : 691 - 699
  • [36] Rational approach to fetal heart rate monitoring and management during the second stage of labor
    Chandraharan, Edwin
    Kahar, Yash
    Pereira, Susana
    Fieni, Stefania
    Ghi, Tullio
    EUROPEAN JOURNAL OF OBSTETRICS & GYNECOLOGY AND REPRODUCTIVE BIOLOGY, 2025, 305 : 159 - 169
  • [37] Toward the improvement in fetal monitoring during labor with the inclusion of maternal heart rate analysis
    Goncalves, Hernani
    Pinto, Paula
    Silva, Manuela
    Ayres-de-Campos, Diogo
    Bernardes, Joao
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (04) : 691 - 699
  • [38] Electronic fetal heart rate monitoring - Another look
    Spong, Catherine Y.
    OBSTETRICS AND GYNECOLOGY, 2008, 112 (03): : 506 - 507
  • [39] PROBLEMS AND SIGNIFICANCE OF ELECTRONIC MONITORING OF FETAL HEART RATE
    KUBLI, F
    RUTTGERS, H
    GEBURTSHILFE UND FRAUENHEILKUNDE, 1974, 34 (01) : 1 - 20
  • [40] Electronic fetal heart rate monitoring: A story of survival
    Parer, JT
    OBSTETRICAL & GYNECOLOGICAL SURVEY, 2003, 58 (09) : 561 - 563