Comparison of myocardial contrast echocardiography with SPECT in the evaluation of coronary artery disease in asymptomatic patients with LBBB

被引:13
|
作者
Karavidas, Apostolos I. [1 ]
Matsakas, Evangellos P. [1 ]
Lazaros, George A. [1 ]
Brestas, Paris S. [1 ]
Avramidis, Dimitrios A. [1 ]
Zacharoulis, Achilleas Ap. [1 ]
Fotiadis, Ioannis N. [1 ]
Korres, Dimitnios A. [1 ]
Zacharoulis, Apostolos Ach. [1 ]
机构
[1] Athens Gen Hosp, Dept Cardiol, Athens, Greece
关键词
left bundle branch block; contrast echocardiography; myocardial perfusion scintigraphy; adenosine; coronary artery disease; diagnostic accuracy;
D O I
10.1016/j.ijcard.2005.10.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The non-invasive assessment of coronary artery disease (CAD) in patients with left bundle branch block (LBBB) is troublesome. In this study, we investigated the diagnostic accuracy of myocardial contrast echocardiography (MCE) with adenosine to detect CAD in asymptomatic patients with LBBB, and we compared it with single photon emission computed tomography (SPECT) with adenosine. Methods: Forty-seven patients with LBBB, and no previously documented CAD, initially underwent SPECT imaging and 1-3 days later MCE. Coronary arteriography was performed within 1 week from the latter procedure. Results: The overall sensitivity, specificity, positive predictive value, negative predictive value, diagnostic accuracy, and K index of concordance of SPECT were 73%, 72%, 44%, 90%, 72%, and 0.37 +/- 0.13, respectively, whereas those of MCE were 91%, 92%, 77%, 97%, 92%, and 0.77 +/- 0.1, respectively (p < 0.05 for all comparisons). Significant CAD was present in 11 patients (23%). Left anterior descending coronary artery was involved in 8 patients, left circumflex artery in 2 patients, and right coronary artery in 4 patients. Concerning the left anterior descending artery disease detection, SPECT had a sensitivity of 75%, a specificity of 79%, a positive predictive value of 43%, a negative predictive value of 94%, and a diagnostic accuracy of 79%. The respective values of MCE were 100% for all of the above variables. Conclusions: MCE with adenosine has a higher global diagnostic accuracy compared to SPECT for the detection of CAD in patients with LBBB, mainly due to the poor specificity of SPECT concerning perfusion defects detection in the left anterior descending artery territory. (c) 2005 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:334 / 340
页数:7
相关论文
共 50 条
  • [41] Usefulness of dobutamine stress myocardial contrast echocardiography for assessing coronary artery disease
    Guo, SZ
    Shu, XH
    Pan, CZ
    Li, YL
    Ge, JB
    Chen, HZ
    CHINESE MEDICAL JOURNAL, 2005, 118 (21) : 1766 - 1772
  • [42] Assessment of coronary artery disease with second harmonic myocardial perfusion contrast echocardiography
    Dong, SH
    Liang, X
    Zhang, SW
    Zhai, LH
    Hu, XS
    Xia, LQ
    Wang, ZY
    Yang, CY
    Yuan, NR
    CHINESE MEDICAL JOURNAL, 2002, 115 (06) : 837 - 841
  • [43] Dual Stress Imaging in evaluation of coronary artery disease: Dobutamine Echocardiography and G-Spect myocardial perfusion
    Ghilardi, A.
    Medolago, G.
    Caccia, A.
    Rossi, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S161 - S161
  • [44] Assessment of Myocardial Perfusion and Systolic Function in Patients with Coronary Artery Disease after Coronary Artery Bypass Surgery by Myocardial Contrast Echocardiography and Two-dimensional Strain Echocardiography
    刘蓉
    邓又斌
    毕小军
    刘娅妮
    熊莉
    陈刘平
    Current Medical Science, 2009, (05) : 664 - 668
  • [45] Assessment of Myocardial Perfusion and Systolic Function in Patients with Coronary Artery Disease after Coronary Artery Bypass Surgery by Myocardial Contrast Echocardiography and Two-dimensional Strain Echocardiography
    Liu, Rong
    Deng, Youbin
    Bi, Xiaojun
    Liu, Yani
    Xiong, Li
    Chen, Liuping
    JOURNAL OF HUAZHONG UNIVERSITY OF SCIENCE AND TECHNOLOGY-MEDICAL SCIENCES, 2009, 29 (05) : 664 - 668
  • [46] Assessment of myocardial perfusion and systolic function in patients with coronary artery disease after coronary artery bypass surgery by myocardial contrast echocardiography and two-dimensional strain echocardiography
    Rong Liu
    Youbin Deng
    Xiaojun Bi
    Yani Liu
    Li Xiong
    Liuping Chen
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2009, 29 : 664 - 668
  • [47] CONTRAST PERFUSION ECHOCARDIOGRAPHY - DISTRIBUTION AND REPRODUCIBILITY OF MYOCARDIAL CONTRAST ENHANCEMENT IN CORONARY-ARTERY DISEASE
    GRIFFIN, B
    TIMMIS, AD
    SOWTON, E
    AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (07): : 538 - 543
  • [48] Potential clinical applications of myocardial contrast echocardiography in evaluating myocardial perfusion in coronary artery disease
    Aggeli, C
    Bonou, M
    Stefanadis, C
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2005, 104 (01) : 1 - 9
  • [49] Myocardial contrast echocardiography accurately predicted coronary artery disease in patients presenting with acute heart failure
    Janardhanan, R
    Hickman, M
    Lahiri, A
    Senior, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (05) : 9A - 9A
  • [50] Microvascular structural correlates of myocardial contrast echocardiography in patients with coronary artery disease and ventricular dysfunction.
    Shimoni, S
    Frangogiannis, NG
    Aggeli, CJ
    Shan, K
    Nagueh, SF
    Reardon, MJ
    Espada, R
    Letsou, GV
    Quinones, MA
    Zoghbi, WA
    CIRCULATION, 2000, 102 (18) : 748 - 748