Gadolinium Retention in the Brain: An MRI Relaxometry Study of Linear and Macrocyclic Gadolinium-Based Contrast Agents in Multiple Sclerosis

被引:27
|
作者
Forslin, Y. [1 ,2 ]
Martola, J. [1 ,2 ]
Bergendal, A. [1 ]
Fredrikson, S. [1 ,3 ]
Wiberg, M. K. [1 ,2 ,4 ]
Granberg, T. [1 ,2 ]
机构
[1] Karolinska Inst, Dept Clin Neurosci, Stockholm, Sweden
[2] Karolinska Univ Hosp, Dept Radiol, C1-46, S-14186 Stockholm, Sweden
[3] Karolinska Univ Hosp, Dept Neurol, Stockholm, Sweden
[4] Linkoping Univ, Dept Med & Hlth Sci, Div Radiol Sci, Linkoping, Sweden
关键词
DENTATE NUCLEUS; SIGNAL-INTENSITY; MAGNETIC-RESONANCE; GLOBUS-PALLIDUS; HEALTHY RATS; ADMINISTRATIONS; GADOBUTROL; IMAGES; ASSOCIATION; GADODIAMIDE;
D O I
10.3174/ajnr.A6112
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Brain gadolinium retention is consistently reported for linear gadolinium-based contrast agents, while the results for macrocyclics are contradictory and potential clinical manifestations remain controversial. Furthermore, most previous studies are based on conventional T1-weighted MR imaging. We therefore aimed to quantitatively investigate longitudinal and transversal relaxation in the brain in relation to previous gadolinium-based contrast agent administration and explore associations with disability in multiple sclerosis. MATERIALS AND METHODS: Eighty-five patients with MS and 21 healthy controls underwent longitudinal and transverse relaxation rate (R-1 and R-2) relaxometry. Patients were divided into linear, mixed, and macrocyclic groups based on previous gadolinium-based contrast agent administration. Neuropsychological testing was performed in 53 patients. The dentate nucleus, globus pallidus, caudate nucleus, and thalamus were manually segmented. Repeatability measures were also performed. RESULTS: The relaxometry was robust (2.0% scan-rescan difference) and detected higher R-1 (dentate nucleus, globus pallidus, caudate nucleus, thalamus) and R-2 (globus pallidus, caudate nucleus) in patients receiving linear gadolinium-based contrast agents compared with controls. The number of linear gadolinium-based contrast agent administrations was associated with higher R-1 and R-2 in all regions (except R-2 in the thalamus). No similar differences and associations were found for the macrocyclic group. Higher relaxation was associated with lower information-processing speed (dentate nucleus, thalamus) and verbal fluency (caudate nucleus, thalamus). No associations were found with physical disability or fatigue. CONCLUSIONS: Previous linear, but not macrocyclic, gadolinium-based contrast agent administration is associated with higher relaxation rates in a dose-dependent manner. Higher relaxation in some regions is associated with cognitive impairment but not physical disability or fatigue in MS. The findings should be interpreted with care but encourage studies into gadolinium retention and cognition.
引用
收藏
页码:1265 / 1273
页数:9
相关论文
共 50 条
  • [41] Is Gadolinium-based Contrast Material Needed for MRI Follow-up of Multiple Sclerosis?
    Saindane, Amit M.
    RADIOLOGY, 2019, 291 (02) : 435 - 436
  • [42] Transplacental gadolinium retention in mice pups and the effect of pregnancy on gadolinium retention in mothers after maternal administration of gadolinium-based contrast agents
    Erdene, Zulu
    Takahito, Nakajima
    Yoshito, Tsushima
    Satomi, Kameo
    Hiroshi, Koyama
    ACTA RADIOLOGICA, 2017, 58 : 24 - 25
  • [43] Consider Risk for Gadolinium Retention in the Brain When Using Gadolinium-based Contrast Media Response
    Beckett, Katrina R.
    Moriarity, Andrew K.
    Langer, Jessica M.
    RADIOGRAPHICS, 2016, 36 (02) : 621 - 621
  • [44] The effect of gadolinium-based contrast-agents on automated brain atrophy measurements by FreeSurfer in patients with multiple sclerosis
    Lie, Ingrid Anne
    Kerklingh, Emma
    Wesnes, Kristin
    van Nederpelt, David R.
    Brouwer, Iman
    Torkildsen, Oivind
    Myhr, Kjell-Morten
    Barkhof, Frederik
    Bo, Lars
    Vrenken, Hugo
    EUROPEAN RADIOLOGY, 2022, 32 (05) : 3576 - 3587
  • [45] Gadolinium-based MRI characterization of leptomeningeal inflammation in multiple sclerosis
    Absinta, Martina
    Vuolo, Luisa
    Rao, Anuradha
    Nair, Govind
    Sati, Pascal
    Cortese, Irene C. M.
    Ohayon, Joan
    Fenton, Kaylan
    Reyes-Mantilla, Maria I.
    Maric, Dragan
    Calabresi, Peter A.
    Butman, John A.
    Pardo, Carlos A.
    Reich, Daniel S.
    NEUROLOGY, 2015, 85 (01) : 18 - 28
  • [46] The effect of gadolinium-based contrast-agents on automated brain atrophy measurements by FreeSurfer in patients with multiple sclerosis
    Ingrid Anne Lie
    Emma Kerklingh
    Kristin Wesnes
    David R. van Nederpelt
    Iman Brouwer
    Øivind Torkildsen
    Kjell-Morten Myhr
    Frederik Barkhof
    Lars Bø
    Hugo Vrenken
    European Radiology, 2022, 32 : 3576 - 3587
  • [47] Clinical Safety of Gadoteridol, Representative of the Macrocyclic Class of Gadolinium-Based Contrast Agents
    Runge, Val Murray
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 51 (03) : 869 - 870
  • [48] Long-term retention of gadolinium in the skin of rodents following the administration of gadolinium-based contrast agents
    Hubertus Pietsch
    Philipp Lengsfeld
    Gregor Jost
    Thomas Frenzel
    Joachim Hütter
    Martin A. Sieber
    European Radiology, 2009, 19 : 1417 - 1424
  • [49] Organ retention of gadolinium in mother and pup mice: effect of pregnancy and type of gadolinium-based contrast agents
    Khongorzul Erdene
    Takahito Nakajima
    Satomi Kameo
    Miski Aghnia Khairinisa
    Oyunbold Lamid-Ochir
    Amartuvshin Tumenjargal
    Noriyuki Koibuchi
    Hiroshi Koyama
    Yoshito Tsushima
    Japanese Journal of Radiology, 2017, 35 : 568 - 573
  • [50] Organ retention of gadolinium in mother and pup mice: effect of pregnancy and type of gadolinium-based contrast agents
    Erdene, Khongorzul
    Nakajima, Takahito
    Kameo, Satomi
    Khairinisa, Miski Aghnia
    Lamid-Ochir, Oyunbold
    Tumenjargal, Amartuvshin
    Koibuchi, Noriyuki
    Koyama, Hiroshi
    Tsushima, Yoshito
    JAPANESE JOURNAL OF RADIOLOGY, 2017, 35 (10) : 568 - 573