Long-term follow-up of DDD pacing mode

被引:6
|
作者
Ulman, Mateusz [1 ]
Debski, Maciej [2 ]
Zabek, Andrzej [2 ]
Haberka, Kazimierz [2 ]
Lelakowski, Jacek [2 ,3 ]
Malecka, Barbara [2 ,3 ]
机构
[1] Med Ctr Niepolomice, Niepolomice, Poland
[2] John Paul II Hosp Krakow, Dept Electrocardiol, PL-31202 Krakow, Poland
[3] Jagiellonian Univ, Med Coll Krakow, Inst Cardiol, PL-31007 Krakow, Poland
关键词
sick sinus syndrome; atrioventricular block; DDD pacing; atrial fibrillation; endocardial lead failure; SICK SINUS SYNDROME; DUAL-CHAMBER; PACEMAKER; PERFORMANCE; BENEFITS; RISK;
D O I
10.5603/KP.a2014.0020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and aim: The aim of this study was to determine the long-term survival of DDD pacing and identify the main reasons for its loss. Methods: The study group consisted of 496 patients in whom a DDD pacing system was implanted between October 1984 and March 2002 and who were followed up until July 2010. The follow-up period was 152.1 +/- 35.5 months. The patients' mean age at the time of implantation was 59.5 +/- 12.5 years, and 53.5% were male; 58% had sick sinus syndrome (SSS), 26% had atrioventricular block (AVB), 15% had both of these indications simultaneously, and 1% had other indications. The incidence of lead malfunction, progression to chronic atrial fibrillation (AF), and the rate of infective complications was analysed. Results: During the follow-up, 369 patients remained in DDD mode stimulation. DDD mode survival rate at one, five, ten and 15 years was, respectively, 96%, 86%, 77% and 72%. The most common reason for reprogramming out of DDD mode was the development of permanent AF in 65 (13.1%) patients. The occurrence of chronic AF was associated with a prior history of paroxysmal AF (p = 0.0001), SSS (p = 0.0215), and older age at time of implantation (p = 0.0068) compared to patients who remained in sinus rhythm. Lead malfunction caused loss of DDD mode pacing in 56 (11.3%) patients. Atrial leads were damaged in 37 patients, ventricular in 12 patients, and both leads in seven patients. The subclavian vein puncture was correlated with the mechanical damage of the atrial lead (p = 0.02935) compared to cephalic vein access. At the moment of complication, the patients with a dysfunctional lead were significantly younger than those who progressed to chronic AF (p = 0.0019). Infective complications which caused temporary loss of DDD pacing were observed in six patients: five had pocket infection and one had lead-dependent infective endocarditis. Conclusions: 1. Effective DDD pacing from the originally implanted system was noted in a high percentage (72%) of patients in long-term observation (15 years). 2. Progression to permanent AF is the most common reason for loss of DDD pacing; a history of paroxysmal AF and old age are the risk factors. 3. Subclavian vein puncture is associated with a higher rate of atrial lead damage.
引用
收藏
页码:519 / 526
页数:8
相关论文
共 50 条
  • [31] TRABECULECTOMY - LONG-TERM FOLLOW-UP
    WILSON, P
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1977, 61 (08) : 535 - 538
  • [32] MYRINGOPLASTY - LONG-TERM FOLLOW-UP
    JUROVITZKI, I
    SADE, J
    AMERICAN JOURNAL OF OTOLOGY, 1988, 9 (01): : 52 - 55
  • [33] LONG-TERM RESULTS AND FOLLOW-UP (18 YEARS) OF PACING IN CHAGAS-DISEASE
    GRECO, OT
    ARDITO, RV
    JACOB, JLB
    NICOLAU, JC
    LORGA, AM
    BRAILE, DM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 611 - 611
  • [34] Long-term follow-up of a malpositioned ventricular pacing lead via the aortic valve
    Naegele, H.
    Azizi, M.
    Hashagen, S.
    Behrens, S.
    CLINICAL RESEARCH IN CARDIOLOGY, 2006, 95 (09) : 488 - 491
  • [35] Long-term follow-up results of the Pacing to Avoid Cardiac Enlargement (PACE) trial
    Yu, Cheuk-Man
    Fang, Fang
    Luo, Xiu-Xia
    Zhang, Qing
    Azlan, Hussin
    Razali, Omar
    EUROPEAN JOURNAL OF HEART FAILURE, 2014, 16 (09) : 1016 - 1025
  • [36] LONG-TERM FOLLOW-UP OF ANTITACHY-PACING (ATPM) FOR SUPRAVENTRICULAR TACHYCARDIAS (PSVT)
    KAPPENBERGER, L
    VALLIN, H
    SOWTON, E
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 694 - 694
  • [37] Long-term follow-up of unipolar configuration in bipolar mixed and polyurethane pacing leads
    Verlato, R
    Bongiorni, MG
    Mantovan, R
    Levorato, D
    Baccillieri, S
    Pantaleoni, A
    Arena, G
    Soldati, E
    Mariani, M
    PACEMAKER LEADS 1997, 1997, : 423 - 426
  • [38] LONG-TERM FOLLOW-UP OF DUAL CHAMBER PACEMAKERS - INCIDENCE AND DURATION OF PHYSIOLOGICAL PACING
    SOLER, M
    PFISTERER, M
    CUENI, T
    BURKART, F
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03): : 745 - 745
  • [39] FACILITATION OF DDD FOLLOW-UP USING THE DDT MODE
    KAMKE, W
    NITSCHKE, M
    GUTSCHKER, A
    WORZEWSKI, W
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (11): : 1836 - 1840
  • [40] Optimal AV delay in DDD paced patients with dilated cardiomyopathy: Short and long-term follow-up
    Toselli, T
    Guardigli, G
    Percoco, GF
    Argnani, MS
    Holzl, A
    Cavazzini, D
    Ferrari, F
    Antonioli, GE
    EUROPACE '97 - THE OFFICIAL MEETING OF THE WORKING GROUPS ON CARDIAC PACING AND ARRHYTHMIAS OF THE EUROPEAN SOCIETY OF CARDIOLOGY, 1997, : 1123 - 1127