Patient-ventilator asynchrony in preterm infants on nasal intermittent positive pressure ventilation

被引:8
|
作者
De Waal, Cornelia G. [1 ]
van Leuteren, Ruud W. [1 ]
de Jongh, Frans H. [1 ]
van Kaam, Anton H. [1 ,2 ]
Hutten, Gerard J. [1 ]
机构
[1] Emma Childrens Hosp, Acad Med Ctr, Dept Neonatol, NL-1100 DD Amsterdam, Netherlands
[2] Vrije Univ Amsterdam Med Ctr, Dept Neonatol, Amsterdam, Netherlands
来源
ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION | 2019年 / 104卷 / 03期
关键词
NONINVASIVE VENTILATION; GRASEBY CAPSULE; SYNCHRONIZATION; ASSIST; NIPPV; NCPAP; EMG;
D O I
10.1136/archdischild-2018-315102
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Objective To describe the incidence of patient-ventilator asynchrony and different types of asynchrony in preterm infants treated with non-synchronised nasal intermittent positive pressure ventilation (nIPPV). Design An observational study was conducted including preterm infants born with a gestational age (GA) less than 32 weeks treated with non-synchronised nIPPV. During 1 hour, spontaneous breathing was measured with transcutaneous electromyography of the diaphragm simultaneous with ventilator inflations. An asynchrony index (AI), a percentage of asynchronous breaths, was calculated and the incidence of different types of inspiratory and expiratory asynchrony were reported. Results Twenty-one preterm infants with a mean GA of 26.0 +/- 1.2 weeks were included in the study. The mean inspiratory AI was 68.3%+/- 4.7% and the mean expiratory AI was 67.1%+/- 7.3%. Out of 5044 comparisons of spontaneous inspirations and mechanical inflations, 45.3% of the mechanical inflations occurred late, 23.3% of the mechanical inflations were early and 31.4% of the mechanical inflation were synchronous. 40.3% of 5127 expiratory comparisons showed an early termination of ventilator inflations, 26.7% of the mechanical inflations terminated late and 33.0% mechanical inflations terminated in synchrony with a spontaneous expiration. In addition, 1380 spontaneous breaths were unsupported and 611 extra mechanical inflations were delivered. Conclusion Non-synchronised nIPPV results in high patient-ventilator asynchrony in preterm infants during both the inspiratory and expiratory phase of the breathing cycle. New synchronisation techniques are urgently needed and should address both inspiratory and expiratory asynchrony.
引用
收藏
页码:F280 / F284
页数:5
相关论文
共 50 条
  • [41] PATIENT-VENTILATOR ASYNCHRONY DURING CONVENTIONAL OR AUTOMATED PRESSURE SUPPORT VENTILATION IN DIFFICULT-TO-WEAN PATIENTS
    Bitondo, M. M.
    Aguirre, H. M.
    Moccaldo, A.
    Grieco, D.
    Roche-Campo, F.
    Antonelli, M.
    Mancebo Cortes, J.
    Maggiore, S. M.
    INTENSIVE CARE MEDICINE, 2012, 38 : S265 - S265
  • [42] Effects of non-synchronised nasal intermittent positive pressure ventilation on spontaneous breathing in preterm infants
    Owen, L. S.
    Morley, C. J.
    Dawson, J. A.
    Davis, P. G.
    ARCHIVES OF DISEASE IN CHILDHOOD-FETAL AND NEONATAL EDITION, 2011, 96 (06): : F422 - F428
  • [43] Patient-ventilator asynchrony during conventional or automated pressure support ventilation in difficult-to-wean patients
    MM Bitondo
    HM Aguirre-Bermeo
    A Moccaldo
    P De Santis
    V Bernini
    A Tersali
    S Italiano
    DL Grieco
    FA Idone
    J Grandjean
    F Roche-Campo
    M Antonelli
    J Mancebo Cortes
    SM Maggiore
    Critical Care, 16 (Suppl 1):
  • [44] DIFFERENCE IN PREVALENCE OF PATIENT-VENTILATOR ASYNCHRONY DURING MECHANICAL VENTILATION BETWEEN MODES
    Heulitt, Mark
    Ranallo, Courtney
    Mireles-Cabodevila, Eduardo
    Thurman, Tracy
    Bannout, Firas
    Holt, Shirley
    CRITICAL CARE MEDICINE, 2012, 40 (12) : U123 - U124
  • [45] Nasal Continuous Positive Airway Pressure vs. Nasal Intermittent Positive Pressure Ventilation as Initial Treatment After Birth in Extremely Preterm Infants
    Kostekci, Yasemin Ezgi
    Okulu, Emel
    Bakirarar, Batuhan
    Kraja, Elvis
    Erdeve, Omer
    Atasay, Begum
    Arsan, Saadet
    FRONTIERS IN PEDIATRICS, 2022, 10
  • [46] Effectiveness of Nasal Intermittent Positive Pressure Ventilation versus Nasal Continuous Positive Airway Pressure in Preterm Infants after Less Invasive Surfactant Administration
    Mahmoud, Ramadan A.
    INTERNATIONAL JOURNAL OF PEDIATRICS-MASHHAD, 2019, 7 (01): : 8915 - 8924
  • [47] Automated Detection of Asynchrony in Patient-Ventilator Interaction
    Mulqueeny, Qestra
    Redmond, Stephen J.
    Tassaux, Didier
    Vignaux, Laurence
    Jolliet, Philippe
    Ceriana, Piero
    Nava, Stefano
    Schindhelm, Klaus
    Lovell, Nigel H.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 5324 - +
  • [48] PATIENT-VENTILATOR ASYNCHRONY: AUTOMATIC DETECTION OF AUTOPEEP
    Quang-Thang Nguyen
    Pastor, Dominique
    L'Her, Erwan
    2012 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING (ICASSP), 2012, : 633 - 636
  • [49] Artificial Intelligence for the Detection of Patient-Ventilator Asynchrony
    Tlimat, Abdulhakim
    Fowler, Cosmo
    Safadi, Sami
    Johnson, Robert B.
    Bodduluri, Sandeep
    Morris, Peter
    Bhatt, Surya P.
    RESPIRATORY CARE, 2025,
  • [50] Algorithm for Automatic Detection of Patient-Ventilator Asynchrony
    Nakamura, M. A.
    Miyasawa, G. J.
    Tucci, M. R.
    Costa, E. V.
    Sousa, M. L.
    Morais, C. C.
    Rossi, F. S.
    Amato, M. B.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2020, 201