Contrast-enhanced color Doppler ultrasonography increases diagnostic accuracy for soft tissue tumors

被引:31
|
作者
Oebisu, Naoto [1 ]
Hoshi, Manabu [1 ]
Ieguchi, Makoto [1 ]
Takada, Jun [1 ]
Iwai, Tadashi [1 ]
Ohsawa, Masahiko [2 ]
Nakamura, Hiroaki [1 ]
机构
[1] Osaka City Univ, Grad Sch Med, Dept Orthoped Surg, Abeno Ku, Osaka 5458585, Japan
[2] Osaka City Univ, Grad Sch Med, Dept Diagnost Pathol, Abeno Ku, Osaka 5458585, Japan
关键词
contrast-enhanced ultrasonography; soft tissue tumor; vascularity; sonazoid; MUSCULOSKELETAL TUMORS; MASSES; DIFFERENTIATION; SONOGRAPHY; BENIGN; ULTRASOUND; EXTREMITY; SPECTRUM; SARCOMA; LESIONS;
D O I
10.3892/or.2014.3378
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Resolution of ultrasonography (US) has undergone marked development. Additionally, a new-generation contrast medium (Sonazoid) used for US is newly available. Contrast-enhanced US has been widely used for evaluating several types of cancer. In the present study, we evaluated the ability of color Doppler US (CDUS) and Sonazoid to differentiate between benign and malignant soft tissue tumors. A total of 180 patients (87 male, 93 female) were enrolled in the present study. The patient ages ranged from 1 to 91 years (mean 58.1 +/- 20.0 years). The maximum size, depth, tumor margins, shape, echogenicity and textural pattern were measured on gray-scale images. CDUS was used to evaluate the intratumoral blood flow with and without Sonazoid. Peak systolic flow velocity (Vp), mean flow velocity (Vm), resistivity index (RI) and pulsatility index (PI) of each detected intratumoral artery were automatically calculated with power Doppler US (PDUS). The present study included 118 benign and 62 malignant tumors. Statistical significances were found in size, depth, tumor margin and textural pattern but not in shape or echogenicity on gray-scale images. Before Sonazoid injection, CDUS findings showed 55% sensitivity, 77% specificity and 69% accuracy, whereas contrast-enhanced CDUS showed 87% sensitivity, 68% specificity and 74% accuracy. There were no statistically significant differences between malignant and benign tumors regarding the mean Vp, Vm, RI and PI values determined on PDUS. In conclusion, contrast-enhanced CDUS proved to be a reliable diagnostic tool for detecting malignant potential in soft tissue tumors.
引用
收藏
页码:1654 / 1660
页数:7
相关论文
共 50 条
  • [41] Contrast-enhanced color Doppler ultrasound characteristics in hypervascular breast tumors: comparison with MRI
    Alamo, L
    Fischer, U
    EUROPEAN RADIOLOGY, 2001, 11 (06) : 970 - 977
  • [42] CONTRAST-ENHANCED ULTRASONOGRAPHY VERSUS CONTRAST-ENHANCED MAGNETIC RESONANCE IMAGING IN THE DIAGNOSIS OF MEDIASTINAL TUMORS
    Pan, Juhong
    Chen, Wenwei
    Zhang, Haidong
    Huang, Xingyue
    Huang, Xin
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2021, 47 (02): : 261 - 271
  • [43] Contrast-enhanced color Doppler sonography of uveal melanomas
    Lemke, AJ
    Hosten, N
    Richter, M
    Bechrakis, NE
    Foerster, P
    Puls, R
    Gutberlet, M
    Felix, R
    JOURNAL OF CLINICAL ULTRASOUND, 2001, 29 (04) : 205 - 211
  • [44] Contrast-enhanced ultrasonography
    Block, Wesley D.
    Atri, Mostafa
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2012, 184 (14) : 1599 - 1599
  • [45] CONTRAST-ENHANCED COLOR DOPPLER IMAGING OF THE CEREBRAL VASCULATURE
    BOYAJIAN, RA
    RUSH, MP
    OTIS, SM
    STROKE, 1993, 24 (03) : 513 - 513
  • [46] Contrast-enhanced transcranial Doppler ultrasonography in the diagnosis of brain death
    Welschehold, Stefan
    Geisel, Florian
    Beyer, Christian
    Reuland, Andre
    Kerz, Thomas
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 2013, 84 (08): : 939 - +
  • [47] Doppler and Contrast-Enhanced Ultrasonography of Testicles in Adult Domestic Felines
    de Brito, M. B. S.
    Feliciano, M. A. R.
    Coutinho, L. N.
    Uscategui, R. R.
    Simoes, A. P. R.
    Maronezi, M. C.
    de Almeida, V. T.
    Crivelaro, R. M.
    Gasser, B.
    Pavan, L.
    Russiano, W. R.
    REPRODUCTION IN DOMESTIC ANIMALS, 2015, 50 (05) : 730 - 734
  • [48] Contrast-Enhanced Ultrasonography and Color Doppler: Guided Intraoperative Embolization of Intracranial Highly Vascularized Tumors (vol 128, pg 547, 2019)
    Della Pepa, Giuseppe Maria
    Marchese, Enrico
    Pedicelli, Alessandro
    Olivi, Alessandro
    Ricciardi, Luca
    Rapisarda, Alessandro
    Skrap, Benjamin
    Sabatino, Giovanni
    La Rocca, Giuseppe
    WORLD NEUROSURGERY, 2019, 131 : 18 - 18
  • [49] Erratum to: Determination of peripheral color signal density using contrast-enhanced color Doppler ultrasonography in diffuse liver disease
    Masao Shinohara
    Journal of Medical Ultrasonics, 2004, 31 (3) : 135 - 135
  • [50] Evaluation of microvascularization in focal salivary gland lesions by contrast-enhanced ultrasonography (CEUS) and Color Doppler sonography
    Wei, Xi
    Li, Ying
    Zhang, Sheng
    Li, Xubin
    Wang, Hailing
    Yong, Xu
    Wang, Xiaoqing
    Li, Xing
    Gao, Ming
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2013, 54 (03) : 259 - 271