A Comparative Study of Dynamic Hip Screw Versus Multiple Cannulated Compression Screw Fixation in Undisplaced Intracapsular Neck of Femur Fractures

被引:4
|
作者
Cullen, Samuel E. [1 ]
Sephton, Benjamin [1 ]
Malik, Isfand [1 ]
Aldarragi, Ameer [1 ]
Crossdale, Martin [1 ]
O'Connor, Michael [1 ]
机构
[1] Stepping Hill Hosp, Trauma & Orthopaed, Stockport, England
关键词
cannulated cancellous screw; dynamic hip screw fixation; neck of femur fracture; intracapsular fracture; fracture around hip; hips;
D O I
10.7759/cureus.31619
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Femoral neck fractures are common injuries. Although many studies have compared two-hole dynamic hip screw (DHS) versus multiple cannulated cancellous screw (CCS) fixation for undisplaced intracapsular fractured neck of femurs (NOF), there is no consensus on which surgical technique results in better outcomes. The aim of our study was to compare DHS and CCS for undisplaced NOFs. The primary outcomes were reoperation and mortality rates at one year postoperatively. Methodology A retrospective analysis was performed involving all patients who underwent fixation with DHS/CCS for an undisplaced intracapsular NOF at our hospital between January 2016 and December 2020. All patients had a minimum follow-up time greater than one year. All patients underwent a standardised NOF protocol. Patients either underwent DHS or CCS fixation according to surgeon preference, and there was no randomisation to either group. Results A total of 41 patients underwent fixation with DHS compared to 32 who underwent CCS. The reoperation rate at one year was 9.8% in the DHS group compared to 6.3% in the CCS group. This difference was not statistically significant (p = 0.588). The one-year mortality rate was similar between groups at 22.0% and 21.9% in the DHS group and the CCS group, respectively (p = 0.994). Registrar-level surgeons performed 80.5% of DHS compared to 59.4% of CCS, and consultant surgeons performed 4.9% of DHS compared to 25% of CCS. Conclusions There was no significant difference in revision rates or complications seen between CCS and DHS. A significantly higher percentage of CCS fixations were performed by consultant-grade surgeons at our hospital compared to DHS. This study provides further data on the choice of fixation method for intracapsular fractures. It also reports on the grade of the operating surgeon at our unit, which may be a factor in the quality of fixation and ultimately reoperation rates.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Fixation of intracapsular femoral neck fractures with a one-hole plate dynamic hip screw
    HeyseMoore, GH
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1996, 27 (03): : 181 - 183
  • [22] A Comparison of Dynamic Hip Screw and Two Cannulated Screws in the Treatment of Undisplaced Intracapsular Neck Fractures-Two-Year Follow-Up of 453 Patients
    Widhalm, Harald Kurt
    Arnhold, Richard
    Beiglboeck, Hannes
    Munteanu, Alexandru
    Lang, Nikolaus Wilhelm
    Hajdu, Stefan
    JOURNAL OF CLINICAL MEDICINE, 2019, 8 (10)
  • [23] Biomechanical properties of a posterior fully threaded positioning screw for cannulated screw fixation of displaced neck of femur fractures
    Schaefer, Thomas K.
    Spross, Christian
    Stoffel, Karl K.
    Yates, Piers J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2015, 46 (11): : 2130 - 2133
  • [24] Fixation of Intertrochanteric Fractures: Dynamic Hip Screw versus Locking Compression Plate
    Mardani-Kivi, Mohsen
    Mirbolook, Ahmadreza
    Jahromi, Sina Khajeh
    Rad, Melina Rouhi
    TRAUMA MONTHLY, 2013, 18 (02) : 67 - 70
  • [25] Cancellous screw fixation for undisplaced femoral neck fractures in the elderly
    Manohara, Ruben
    Liang, Shen
    Huang, Deborah
    Krishna, Lingaraj
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (03) : 282 - 286
  • [26] Percutaneous compression cannulated screw fixation for ankle fractures
    Li, Changhua
    Peng, Maoxiu
    Lin, Guangmao
    Chen, Wenliang
    Wang, Weiliang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2018, 11 (03): : 2489 - 2494
  • [27] HIP COMPRESSION SCREW VERSUS NAIL PLATE FIXATION OF FEMORAL-NECK FRACTURES
    BENUM, P
    SVENNINGSEN, S
    NESSE, O
    FURSET, OI
    ACTA ORTHOPAEDICA SCANDINAVICA, 1984, 55 (03): : 387 - 388
  • [28] Cannulated Screws V Dynamic Hip Screw Fixation For Undisplaced Intra-Capsular Hip Fractures - What Do We Prefer To Do?
    Asokan, A.
    Khan, S.
    Moores, T.
    Bartlett, J.
    Briggs, T.
    BRITISH JOURNAL OF SURGERY, 2020, 107 : 135 - 135
  • [29] The value of washers in cannulated screw fixation of femoral neck fractures
    Zlowodzki, M
    Weening, B
    Petrisor, B
    Bhandari, M
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 59 (04): : 969 - 975
  • [30] Cannulated versus non-cannulated cancellous screw fixation for femoral neck fractures: a synthetic bone biomechanical study
    Mutlu, Harun
    Mutlu, Serhat
    JOURNAL OF ORTHOPAEDIC SURGERY, 2015, 23 (02) : 271 - 271