Advanced Modeled Iterative Reconstruction in Low-Tube-Voltage Contrast-Enhanced Neck CT: Evaluation of Objective and Subjective Image Quality

被引:20
|
作者
Scholtz, J. -E. [1 ]
Kaup, M. [1 ]
Huesers, K. [1 ]
Albrecht, M. H. [1 ]
Bodelle, B. [1 ]
Metzger, S. C. [1 ]
Kerl, J. M. [1 ]
Bauer, R. W. [1 ]
Lehnert, T. [1 ]
Vogl, T. J. [1 ]
Wichmann, J. L. [1 ,2 ]
机构
[1] Univ Hosp Frankfurt, Dept Diagnost & Intervent Radiol, Frankfurt, Germany
[2] Med Univ S Carolina, Dept Radiol & Radiol Sci, Charleston, SC 29425 USA
关键词
AUTOMATIC EXPOSURE CONTROL; COMPUTED-TOMOGRAPHY; DOSE REDUCTION; HEAD;
D O I
10.3174/ajnr.A4502
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Dose-saving techniques in neck CT cause increased image noise that can be counteracted by iterative reconstruction. Our aim was to evaluate the image quality of advanced modeled iterative reconstruction (ADMIRE) in contrast-enhanced low-tube-voltage neck CT. MATERIALS AND METHODS: Sixty-one patients underwent 90-kV(peak) neck CT by using third-generation 192-section dual-source CT. Image series were reconstructed with standard filtered back-projection and ADMIRE strength levels 1, 3, and 5. Attenuation and noise of the sternocleidomastoid muscle, internal jugular vein, submandibular gland, tongue, subscapularis muscle, and cervical fat were measured. Signal-to-noise and contrast-to-noise ratios were calculated. Two radiologists assessed image noise, image contrast, delineation of smaller structures, and overall diagnostic acceptability. Interobserver agreement was calculated. RESULTS: Image noise was significantly reduced by using ADMIRE compared with filtered back-projection with the lowest noise observed in ADMIRE 5 (filtered back-projection, 9.4 2.4 Hounsfield units [HU]; ADMIRE 1, 8.3 +/- 2.8 HU; ADMIRE 3, 6.7 +/- 2.0 HU; ADMIRE 5, 5.4 +/- 1.7 HU; all, P < .001). Sternocleidomastoid SNR and internal jugular vein-sternocleidomastoid contrast-to-noise ratios were significantly higher for ADMIRE with the best results in ADMIRE 5 (all, P < .001). Subjective image quality and image contrast of ADMIRE 3 and 5 were consistently rated better than those for filtered back-projection and ADMIRE 1 (all, P < .001). Image noise was rated highest for ADMIRE 5 (all, P < .005). Delineation of smaller structures was voted higher in all ADMIRE strength levels compared with filtered back-projection (P < .001). Global interobserver agreement was good (0.75). CONCLUSIONS: Contrast-enhanced 90-kVp neck CT is feasible, and ADMIRE 5 shows superior objective image quality compared with filtered back-projection. ADMIRE 3 and 5 show the best subjective image quality.
引用
收藏
页码:143 / 150
页数:8
相关论文
共 50 条
  • [11] CT Angiography of the Head-and-Neck Vessels Acquired with Low Tube Voltage, Low Iodine, and Iterative Image Reconstruction: Clinical Evaluation of Radiation Dose and Image Quality
    Zhang, Wei-lan
    Li, Min
    Zhang, Bo
    Geng, Hai-yang
    Liang, Yin-qiang
    Xu, Ke
    Li, Song-bai
    PLOS ONE, 2013, 8 (12):
  • [12] Image quality and radiation dose of low-tube-voltage CT with reduced contrast media for right adrenal vein imaging
    Takahashi, Yuki
    Ota, Hideki
    Omura, Kensuke
    Dendo, Yutaka
    Otani, Katharina
    Matsuura, Tomonori
    Kitami, Masahiro
    Seiji, Kazumasa
    Tezuka, Yuta
    Nezu, Masahiro
    Ono, Yoshikiyo
    Morimoto, Ryo
    Satoh, Fumitoshi
    Takase, Kei
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 98 : 150 - 157
  • [13] Iterative model reconstruction: Improved image quality of low-tube-voltage prospective ECG-gated coronary CT angiography images at 256-slice CT
    Oda, Seitaro
    Weissman, Gaby
    Vembar, Mani
    Weigold, Wm. Guy
    EUROPEAN JOURNAL OF RADIOLOGY, 2014, 83 (08) : 1408 - 1415
  • [14] Can iterative reconstruction algorithms replace tube loading compensation in low kVp hepatic CT? Subjective versus objective image quality
    Holmquist, Fredrik
    Soederberg, Marcus
    Nyman, Ulf
    Faelt, Tobias
    Siemund, Roger
    Geijer, Mats
    ACTA RADIOLOGICA OPEN, 2020, 9 (03)
  • [15] Low-Tube-Voltage 80-kVp Neck CT: Evaluation of Diagnostic Accuracy and Interobserver Agreement
    Wichmann, J. L.
    Kraft, J.
    Noeske, E. -M.
    Bodelle, B.
    Burck, I.
    Scholtz, J. -E.
    Frellesen, C.
    Wagenblast, J.
    Kerl, J. M.
    Bauer, R. W.
    Lehnert, T.
    Vogl, T. J.
    Schulz, B.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (12) : 2376 - 2381
  • [16] Image quality evaluation of iterative model reconstruction on low tube voltage (80 kVp) coronary CT angiography in an animal study
    Hu, Mao-Qing
    Li, Meng
    Liu, Zai-Yi
    Huang, Mei-Ping
    Liu, Hui
    Liang, Chang-Hong
    ACTA RADIOLOGICA, 2016, 57 (02) : 170 - 177
  • [17] Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose
    Chien-Ming Chen
    Sung-Yu Chu
    Ming-Yi Hsu
    Ying-Lan Liao
    Hui-Yu Tsai
    European Radiology, 2014, 24 : 460 - 468
  • [18] Low-tube-voltage (80 kVp) CT aortography using 320-row volume CT with adaptive iterative reconstruction: lower contrast medium and radiation dose
    Chen, Chien-Ming
    Chu, Sung-Yu
    Hsu, Ming-Yi
    Liao, Ying-Lan
    Tsai, Hui-Yu
    EUROPEAN RADIOLOGY, 2014, 24 (02) : 460 - 468
  • [19] Application of 80-kVp tube voltage, low-concentration contrast agent and iterative reconstruction in coronary CT angiography: evaluation of image quality and radiation dose
    Wu, Qiyong
    Wang, Yong
    Kai, Huihua
    Wang, Tao
    Tang, Xiaoqiang
    Wang, Xiaoqin
    Pan, Changjie
    INTERNATIONAL JOURNAL OF CLINICAL PRACTICE, 2016, 70 (9B) : B50 - B55
  • [20] Iterative Reconstruction Leads to Increased Subjective and Objective Image Quality in Cranial CT in Patients With Stroke
    Bodelle, Boris
    Wichmann, Julian L.
    Scholtz, Jan-Eric
    Lehnert, Thomas
    Vogl, Thomas J.
    Luboldt, Wolfgang
    Schulz, Boris
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 205 (03) : 618 - 622