Measurement uncertainty in manual differential leukocyte counting

被引:33
|
作者
Fuentes-Arderiu, Xavier [1 ]
Dot-Bach, Dolors [1 ]
机构
[1] Hosp Univ Bellvitge, IDIBELL, Clin Lab, Lhospitalet De Llobregat 08907, Catalonia, Spain
关键词
differential leukocyte count; interpretation of results; ISO; 15189; measurement uncertainty;
D O I
10.1515/CCLM.2009.014
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: One of the most frequently requested examinations in the clinical laboratory is the differential leukocyte count. Despite many technological improvements, thousands of differential leukocyte counts are made by microscopic examination of a blood smear, counting 100 leukocytes and expressing the fraction of the specific leukocyte types as percentages (rounded to integer values) of the total leukocyte count. Although in the clinical laboratory it is not usual practice to report measurement uncertainties, currently the ISO 15189 standard considers measurement uncertainty as a very helpful element for a comprehensive interpretation of any measurement result. Methods: The estimation of the measurement uncertainty of each differential leukocyte count result was carried out according to international guidelines. The sources of standard uncertainty taken into account were: pre- metrological variation, random distribution, between-examiner reproducibility, and rounding to an integer. Results: In this example, a sample of blood with a concentration number of leukocytes of 3,5 X 10(9)/L-1) is taken into consideration. For each differential leukocyte count result, the standard uncertainties corresponding to each source of measurement uncertainty, as well as the combined and the expanded uncertainties, were estimated with information from the literature. Conclusions: The procedure presented here to estimate the measurement uncertainty of differential leukocyte count results is appropriate to fulfill the requirements of the ISO 15189 standard related to measurement uncertainty. Knowledge of this uncertainty is helpful in interpreting sequential results obtained in the same patient.
引用
收藏
页码:112 / 115
页数:4
相关论文
共 50 条
  • [31] Uncertainty of nuclear counting
    Pomme, S.
    Fitzgerald, R.
    Keightley, J.
    METROLOGIA, 2015, 52 (03) : S3 - S17
  • [32] Uncertainty in measurements by counting
    Bich, Walter
    Pennecchi, Francesca
    METROLOGIA, 2012, 49 (01) : 15 - 19
  • [33] Study on the correlation between radioactive counting time and measurement uncertainty of ceramic materials
    Hong Wei
    Li Wen-Jie
    Weng Xiao-Wei
    Zhang Yi-qin
    Liu Xiao-Hui
    Xu Wen-Chao
    Tian Hao
    Wang Ming
    JOURNAL OF ASIAN CERAMIC SOCIETIES, 2022, 10 (04): : 788 - 797
  • [34] UNCERTAINTY OF MEASUREMENT IN FLUID-FLOW MEASUREMENT ON THE BASIS OF DIFFERENTIAL PRESSURE METHODS
    BAJSIC, I
    DOLENC, I
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 1994, 40 (3-4): : 107 - 114
  • [35] EVALUATION OF THE CAPABILITY OF BODY FLUID CELL COUNTING AND LEUKOCYTE DIFFERENTIAL OF THE UNICEL DXH 800 ANALYZER
    Rodriguez-Hernandez, Ines
    Carbonell, Marina
    Leis, Alba
    Galan, Amparo
    Pastor, Maria-Cruz
    Feliu, Evarist
    Milla, Fuensanta
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2014, 36 : 87 - 88
  • [36] EVALUATION OF AN AUTOMATED DIFFERENTIAL LEUKOCYTE COUNTING SYSTEM .1. INSTRUMENT DESCRIPTION AND REPRODUCIBILITY STUDIES
    DUTCHER, TF
    BENZEL, JE
    EGAN, JJ
    HART, DJ
    CHRISTOPHER, EA
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1974, 62 (04) : 525 - 529
  • [37] Comparing automated vs manual leukocyte differential counts for quantifying the 'left shift' in the blood of neonates
    MacQueen, B. C.
    Christensen, R. D.
    Yoder, B. A.
    Henry, E.
    Baer, V. L.
    Bennetts, S. T.
    Yaish, H. M.
    JOURNAL OF PERINATOLOGY, 2016, 36 (10) : 843 - 848
  • [38] Comparing automated vs manual leukocyte differential counts for quantifying the ‘left shift’ in the blood of neonates
    B C MacQueen
    R D Christensen
    B A Yoder
    E Henry
    V L Baer
    S T Bennett
    H M Yaish
    Journal of Perinatology, 2016, 36 : 843 - 848
  • [39] LEUKOCYTE DIFFERENTIAL
    HOYER, JD
    MAYO CLINIC PROCEEDINGS, 1993, 68 (10) : 1027 - 1028
  • [40] AVIAN LEUKOCYTE COUNTING USING THE HEMOCYTOMETER
    DEIN, FJ
    WILSON, A
    FISCHER, D
    LANGENBERG, P
    JOURNAL OF ZOO AND WILDLIFE MEDICINE, 1994, 25 (03) : 432 - 437