A Zirconia-Nanoparticles-Modified Carbon Paste Electrode for Voltammetric Determination of Ibuprofen

被引:2
|
作者
Stoytcheva, Margarita [1 ]
Zlatev, Roumen [1 ]
Velkova, Zdravka [2 ]
Gochev, Velizar [3 ]
Valdez, Benjamin [1 ]
Curiel, Mario [1 ]
机构
[1] Univ Autonoma Baja California, Inst Ingn, Mexicali 21280, Mexico
[2] Med Univ Plovdiv, Fac Pharm, Dept Chem Sci, Plovdiv, Bulgaria
[3] Plovdiv Univ P Hilendarski, Fac Biol, Dept Biochem & Microbiol, Plovdiv, Bulgaria
来源
CHEMISTRYSELECT | 2022年 / 7卷 / 48期
关键词
ibuprofen; differential pulse adsorptive stripping voltammetry; pharmaceutical analysis; zirconia-modified carbon paste electrode; PHARMACEUTICALS; PARACETAMOL;
D O I
10.1002/slct.202203950
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Zirconia-modified carbon paste electrode (ZrO2/CPE) was prepared, characterized, and applied for efficient ibuprofen quantification by differential pulse adsorptive stripping voltammetry. The increased surface area of the modified electrode (up to 74 %), combined with the excellent zirconia adsorption performance allowed a 36 % signal increase to be achieved compared to bare CPE. Under optimized experimental conditions (69 : 1 w % graphite to ZrO2 ratio, 5 min accumulation time, pH 4.5) the ZrO2/CPE exhibited a linear response to ibuprofen in the range from 20 mu mol L-1 to 250 mu mol L-1. The LOD of 4 mu mol L-1 (S/N=3) attained was found to be sufficient to perform ibuprofen analysis in pharmaceutical formulations. The results were validated by ibuprofen determination in commercial tablets with satisfactory recovery values (98.8-102 %). The presence of common pharmaceutical excipients did not affect the ibuprofen voltammetric response. The proposed sensor also demonstrated good reproducibility (RSD=2.84 %) and long term stability.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Voltammetric copper(II) determination with a montmorillonite-modified carbon paste electrode
    Kula, P
    Navratilova, Z
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1996, 354 (5-6): : 692 - 695
  • [32] Manganese dioxide-modified carbon paste electrode for voltammetric determination of riboflavin
    Eda Mehmeti
    Dalibor M. Stanković
    Sudkate Chaiyo
    Ľubomir Švorc
    Kurt Kalcher
    Microchimica Acta, 2016, 183 : 1619 - 1624
  • [33] Voltammetric Determination of Boron using Cobalt Phthalocyanine Modified Carbon Paste Electrode
    Tunay, Zeki
    Sahin, Ibrahim
    Nakiboglu, Nuri
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (12): : 6628 - 6638
  • [34] Voltammetric behavior and determination of bismuth on sodium humate modified carbon paste electrode
    Wang, CM
    Sun, QY
    Li, HL
    ELECTROANALYSIS, 1997, 9 (08) : 645 - 649
  • [35] Voltammetric determination of imazaquin using polyaniline modified carbon paste electrode (CPE)
    Consolin, N
    Venâncio, EC
    de Medeiros, ES
    Tanimoto, ST
    Machado, SAS
    Mattoso, LHC
    SENSOR LETTERS, 2006, 4 (01) : 11 - 16
  • [37] Voltammetric copper(II) determination with a montmorillonite-modified carbon paste electrode
    Institute of Geonics, Academy of, Sciences of Czech Republic,, Studertska 1768, 708 00 Ostrava, Czech Republic
    Fresenius J Anal Chem, 5-6 (692-695):
  • [38] VOLTAMMETRIC DETERMINATION OF PENTACHLOROPHENOL WITH A SILICA GEL-MODIFIED CARBON PASTE ELECTRODE
    BARRIO, MAR
    CARRAZON, JMP
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1992, 344 (1-2): : 34 - 38
  • [39] Voltammetric Determination of Carbidopa Using a modified Multiwall Carbon Nanotube Paste Electrode
    Mohadesi, Alireza
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2012, 7 (03): : 2430 - 2439
  • [40] Voltammetric determination of trace amounts of permanganate at a zeolite modified carbon paste electrode
    Nosuhi, Motahare
    Nezamzadeh-Ejhieh, Alireza
    NEW JOURNAL OF CHEMISTRY, 2017, 41 (24) : 15508 - 15516