Measurements of intermediate-frequency electric and magnetic fields in households

被引:32
|
作者
Aerts, Sam [1 ]
Calderon, Carolina [2 ]
Valic, Blaz [3 ]
Maslanyj, Myron [2 ]
Addison, Darren [2 ]
Mee, Terry [2 ]
Goiceanu, Cristian [2 ]
Verloock, Leen [1 ]
Van den Bossche, Matthias [1 ]
Gajsek, Peter [3 ]
Vermeulen, Roel [4 ]
Roosli, Martin [5 ,6 ]
Cardis, Elisabeth [7 ,8 ]
Martens, Luc [1 ]
Joseph, Wout [1 ]
机构
[1] Ghent Univ iMinds, Dept Informat Technol, iGent, Technol Pk Zwijnaarde 15, B-9052 Ghent, Belgium
[2] Publ Hlth England, Ctr Radiat Chem & Environm Hazards, Didcot OX11 0RQ, Oxon, England
[3] Inst Nonionizing Radiat INIS, Pohorskega Bataljona 215, Ljubljana 1000, Slovenia
[4] Univ Utrecht, Inst Risk Assessment Sci, Dept Environm Epidemiol, Yalelaan 2, NL-3508 Utrecht, Netherlands
[5] Swiss Trop & Publ Hlth Inst Swiss TPH, Socinstr 57,POB, CH-4002 Basel, Switzerland
[6] Univ Basel, Peterspl 1, CH-4003 Basel, Switzerland
[7] Barcelona Inst Global Hlth ISGlobal, Doctor Aiguader 88, Barcelona 08003, Spain
[8] Municipal Inst Med Res IMIM Hosp Mar, Doctor Aiguader 88, Barcelona 08003, Spain
关键词
Electric and magnetic fields; Human exposure; Intermediate frequencies; Household appliances; Epidemiology; IN-SITU EXPOSURE; ELECTROMAGNETIC-FIELDS; APPLIANCES; CHILDREN; SYSTEMS;
D O I
10.1016/j.envres.2017.01.001
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Historically, assessment of human exposure to electric and magnetic fields has focused on the extremely-low frequency (ELF) and radiofrequency (RF) ranges. However, research on the typically emitted fields in the intermediate-frequency (IF) range (300 Hz to 1 MHz) as well as potential effects of IF fields on the human body remains limited, although the range of household appliances with electrical components working in the IF range has grown significantly (e.g., induction cookers and compact fluorescent lighting). In this study, an extensive measurement survey was performed on the levels of electric and magnetic fields in the IF range typically present in residences as well as emitted by a wide range of household appliances under real-life circumstances. Using spot measurements, residential IF field levels were found to be generally low, while the use of certain appliances at close distance (20 cm) may result in a relatively high exposure. Overall, appliance emissions contained either harmonic signals, with fundamental frequencies between 6 kHz and 300 kHz, which were sometimes accompanied by regions in the IF spectrum of rather noisy, elevated field strengths, or much more capricious spectra, dominated by 50 Hz harmonics emanating far in the IF domain. The maximum peak field strengths recorded at 20 cm were 41.5 V/m and 2.7 A/m, both from induction cookers. Finally, none of the appliance emissions in the IF range exceeded the exposure summation rules recommended by the International Commission on Non-Ionizing Radiation Protection guidelines and the International Electrotechnical Commission (IEC 62233) standard at 20 cm and beyond (maximum exposure quotients EQ(E) 1.0 and (E)Q(H) 0.13).
引用
收藏
页码:160 / 170
页数:11
相关论文
共 50 条
  • [21] INTERMEDIATE-FREQUENCY GAIN STABILIZATION WITH INVERSE FEEDBACK
    MONTGOMERY, GF
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1950, 38 (06): : 662 - 667
  • [22] Splitting of Vacuum Arc Column in Transverse Magnetic Field Contacts at Intermediate-Frequency
    Zhu Liying
    Qiao Ming
    Wu Jianwen
    Cui Bo
    2015 3RD INTERNATIONAL CONFERENCE ON ELECTRIC POWER EQUIPMENT - SWITCHING TECHNOLOGY (ICEPE-ST), 2015, : 541 - 545
  • [23] Magneto-Optical Probe With Integrated Optical Elements for Measuring Environmental Magnetic Fields in the Low- and Intermediate-Frequency Bands
    Kato, Yoshihito
    Suzuki, Yukihisa
    Wake, Kanako
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [25] Assessment of combined exposure to intermediate-frequency electromagnetic fields and pulsed electromagnetic fields among library workers in Japan
    Yamaguchi-Sekino, Sachiko
    Taki, Masao
    Ikuyo, Miwa
    Esaki, Kaoru
    Aimoto, Atsuko
    Wake, Kanako
    Kojimahara, Noriko
    FRONTIERS IN PUBLIC HEALTH, 2022, 10
  • [26] External axial magnetic field excitation system in intermediate-frequency current interruption experiment
    Jiang, Yuan
    Wu, Jianwen
    Tang, Wei
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2015, 30 (09): : 39 - 45
  • [27] ABSORPTION AND AMPLIFICATION OF ULTRASOUND OF INTERMEDIATE-FREQUENCY IN SEMICONDUCTORS
    GALPERIN, YM
    PARDAEV, A
    FIZIKA TVERDOGO TELA, 1977, 19 (05): : 1374 - 1378
  • [28] CONSIDERATIONS IN THE DESIGN OF A RADAR INTERMEDIATE-FREQUENCY AMPLIFIER
    HOPPER, AL
    MILLER, SE
    PROCEEDINGS OF THE INSTITUTE OF RADIO ENGINEERS, 1947, 35 (11): : 1208 - 1219
  • [29] MICROWAVE DISCRIMINATORS WITH INTERMEDIATE-FREQUENCY ERROR SIGNAL
    MENDE, FF
    PRENTSLA.NN
    DMITRIYE.VM
    TELECOMMUNICATIONS AND RADIO ENGINEER-USSR, 1971, (01): : 106 - &
  • [30] Arcing Behavior on TMF Contacts at Intermediate-Frequency
    Zhu Liying
    Wu Jianwen
    Liu Bin
    Feng Ying
    25TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2012), 2012, : 281 - 284